FLUKE 6060AAN Instruction 电路图.pdf

上传人:cc518 文档编号:201686 上传时间:2025-03-08 格式:PDF 页数:272 大小:9MB
下载 相关 举报
FLUKE 6060AAN Instruction 电路图.pdf_第1页
第1页 / 共272页
FLUKE 6060AAN Instruction 电路图.pdf_第2页
第2页 / 共272页
FLUKE 6060AAN Instruction 电路图.pdf_第3页
第3页 / 共272页
亲,该文档总共272页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《FLUKE 6060AAN Instruction 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 6060AAN Instruction 电路图.pdf(272页珍藏版)》请在收音机爱好者资料库上搜索。

1、Thank you very much for your shopping on us, if you need any other manual, email me at , I will do my best to help you. Please visit our website at for more manuals. If you find any others selling the manual made by me, please email me also. Attention Please: The listing of this manual is to help th

2、ose who need this manual to repair and maintain their equipment. If you want to buy this manual, you must agree that this manual is only charged for Labeling, Service (List Price), Shipping and Handling Fee; Thanks and enjoy reading. MicroManuals or Micromanuals.COM on Ebay MicroManuals MicroManuals

3、 MicroManuals MicroManuals RadioFans.CN 收音机爱 好者资料库 - OOA/AN Synthesized Signal Generator and FM Modulation Meter Combination NSN 726625012225007 The 6060A/AN combines the capabilities of one of the most successful general-purpose synthesized signal generators in the world, the Fluke 6060A, with the

4、ability to measure FM deviation in one stand-alone unit. -. .lhe signal generator portion of this advanced unit has all of the features you would expect from Flukes RF design engineers including frequency range from 10 kHz to 520 MHz, + 13 dBm to -127 dBm output amplitude range and AM and FM modulat

5、ions. The maximum FM deviation is 500 k usah!e to + ! 5 AEm. FLY- 30 Hz elsewhere. Residual FM (rms in 0.05-kHz to 15-kHz Band): 30 Hz from 245 to 520 MHz; 60 Hz elsewhere. Noise (at 20 kHz offset): - 113 dBc/Hz (except - 107 dBc/Hz below 245 MHz). Spurious: -60 dBc for offsets greater than 10 kHz.

6、Fixed frequency spurs are - 60 dBc or ) MicroManuals MicroManuals MicroManuals MicroManuals TABLE OF CONTENTS. continued SECTION TITLE PAGE . Address Decoder Display and Controls . SYNTHESIZER TROUBLESHOOTING . Reference Circuitry Check . Main Phase Lock Loop . Sub-synthesizer and HET (800 MHz). 40-

7、MHz Loop . FM Circuitry . LEVEL TROUBLESHOOTING . OUTPUT ASSEMBLY TEST POINT SIGNAL INFORMATION . ATTENUATORI RPP LEVEL CONTROL . AttenuatorCheck . Unleveled Condition . n nn n.i . T T L I I C L K . AM TROUBLESHOOTING . . Internall External AM . ALC Loop Control Voltage Detector Linearity . DEVIATIO

8、N METER TROUBLESHOOTING . . A/ D Discriminator . . 5 LIST OF REPLACEABLE PARTS 5-1 . TABLE OF CONTENTS 5-1 . 5 . 1 . INTRODUCTION 5-2 . 5.2 . Parts List Information 5-2 . 5.3 . HOW TO OBTAIN PARTS 5-2 . 5-4 . Recommended Spare Parts Kit 5-3 . 6 OPTIONS 6-1 . TABLE OF CONTENTS 6-1 . 7 GENERAL INFORMA

9、TION 7-1 7.1 . FEDERAL SUPPLY CODES FOR MANUFACTURERS . 7-2 7.2 . U.S. SALES AREAS FOR ALL FLUKE PRODUCTS . 7-3 7.3 . INTERNATIONAL SALES OFFICES . 7-5 . 7-4 . TECHNICAL SERVICE CENTERS 7-6 . 7A MANUAL CHANGE INFORMATION 7A-1 . 8 SCHEMATIC DIAGRAMS 8-1 . TABLE OF CONTENTS 8-1 MicroManuals MicroManua

10、ls MicroManuals MicroManuals TABLE TITLE PAGE . Signal Generator Specifications 1-5 . Front Panel Controls. Indicators. and Connectors 2-5 . Rear Panel Controls. Connectors. and Switches 2-11 . Instrument Preset State 2-12 . Special Functions 2-14 . UNCAL Error Codes 2-27 . REJect ENTRY Codes 2-28 .

11、 Index of IEEE-488 Commands 2-31 . IEEE-488 Commands 2-32 . IEEE-488 Interface Functions List 2-41 . IEEE-488 Address Mode Message Descriptions 2-42 . Suffix Types 2-48 . Learn Character to Hexadecimal Conversion 2-56 . . Interface Mode Commands ; 2-57 . Self-Test Error Codes 2-59 . Input / Output M

12、onitor Commands 2-60 . Read/ Write Monitor Commands 2-61 . Hardware Control Monitor Commands 2-61 . SRQ Mask and Status Values 2-63 . Command-Parsing Time 2-65 . Typical Programming Time of the Generator Functions 2-65 . IEEE-488 Power-On State 2-66 . Power Supply Rectifier Configuration 3-27 . Reco

13、mmended Test Equipment 4A-2 . Modulation Tests Requirements 4A-13 . AM Test Conditions 4A-15 . AM Depth Range 4A-15 . Module Exchange Assemblies 4D-2 . Self Test Display Field 4D-6 . AAA Field AM and FM Tests 4D-6 . BBB Field Test Results 4D-7 . CCC Field Test Results 4D-7 . DDD Field Test Results 4

14、D-7 . Band. Filter. and Frequency Programming Data 4D-8 . Power Supply Characteristics 4D-9 . Address Codes for the Front Panel Keys 4D-12 . Synthesizer PCA Test Points 4A-13 . Frequency Reference Control 4D-14 FM Range . 4D-16 vii (Continued on page viii) MicroManuals MicroManuals MicroManuals Micr

15、oManuals LIST OF TABLES. continued TABLE TITLE PAGE . FM DAC Control 4D-16 Output PCA Test Points . 4D-17 Attenuator Level Control . 4D-18 Attenuator Levels . 4D-18 Modulation On/Off Control . 4D-20 Modulation Frequency Control . 4D-20 Deviation Meter Control . 4D-22 viii MicroManuals MicroManuals M

16、icroManuals MicroManuals List of Illustrations Frontispiece 2.1 . 2.2 . 2.3 . 2 4 . 2.5 . 2.6 . 2.7 . 3 . 1 . 3.2 . 3.3 . 4A.1 . 4A.2 . 4A.3 . 4C- 1 . 4C.2 . 4C.3 . 4C4 . T!TLE PAGE . 6060A /AN Signal Generator x . Fuse/ Filter/ Line Voltage Selection Assembly 2-2 . 6060A/ AN Outside Dimensions 2 4

17、. Front Panel Controls. Indicators. and Connectors 2-5 . Rear Panel Controls. Connectors. and Switches 2-11 . 6060A/AN Signal Generator Connected to a 1722A 2-31 . 6060A/AN IEEE488 Bus Connected to a 6060A IEEE-488 Bus 245 . Learn String Example 2-51 . Triple-Modulus Prescaler Operation 3-13 . N-Div

18、ider Operation 3-14 . N-Divider Timing Diagram 3-15 . TWO-Turn Loop 4A-1 . High-Level Accuracy Test Conditions 4A-5 . High-Level Accuracy Test Conditions 4A-6 . Power Supply Test Points 4C-3 . Module Plate. Bottom View 4C-5 . Module late. Top View 4C-12 . Deviation Meter Module. Top View 4C-16 Micro

19、Manuals MicroManuals MicroManuals MicroManuals I 6060A/AN Synthesized Signal Generator X MicroManuals MicroManuals MicroManuals MicroManuals Section 1 Introduction and Specifications 1-1. INTRODijCTiON The 6060A/AN Synthesized Signal Generator (referred to as the Generator or instrument) is a fully-

20、programmable, precision, synthesized signal generator. In addition, an FM deviation meter is included. The Generator is designed for applications that require good modulation, frequency accuracy, and output level performance with moderate spectral purity. It is well suited for testing a wide variety

21、 of RF components and systems including filters, amplifiers, mixers, and radios, particularly on-channel radio testing. 1-2. UNPACKING THE GENERATOR This shipping container should include a 6060A/ AN Signal Generator, two Instruction Manuals, and a line power cord. Any accessories ordered for the Ge

22、nerator are shipped in a separate container. Section 2, Installation and Operation, gives instructions on inspecting your new Generator. Reshipment information is also included. 1-3. SAFETY This instruction manual contains information, warnings, and cautions that should be followed to ensure safe op

23、eration and to maintain the Generator in a safe condition. The Generator is designed primarily for indoor use, and it may be operated in temperatures from OC to 50C without degradation of its safety. WARNING TO AVOID ELECTRIC SHOCK, USE A POWER CORD THAT HAS A THREE- PRONG PLUG. IF YOU DO NOT USE A

24、PROPER POWER CORDITHE 6060AlAN CASE CAN DEVELOP AN ELECTRICAL POTENTIAL ABOVE EARTH GROUND. CAUTION To avoid damage to the 6060A/AN, check that the rear panel line voltage selection card and fuse are correct for the line voltage in your area. The correct line voltage and fuse combinations are: LINE

25、VOLTAGE FUSE 115V ac, tlOc/i. 47 Hz to 400 Hz 1.5 AMP 230V ac, ilOc/r, 47 Hz to 400 H7 .75 AMP MicroManuals MicroManuals MicroManuals MicroManuals INTRODUCTION AND SPECIFICATIONS 1-4. GENERATOR DESCRIPTION Fundamental features of the Generator are as follows: 0.01-MHz to 520-MHz output frequency ran

26、ge in 10-Hz steps +13-dBm to -127-dBm level range in 0. I-dB steps AM and FM, internal or external Internal 400-Hz and 1000-Hz modulation oscillator FM Deviation Meter Relative frequency and amplitude Volts 1 dBm conversion Store; recall memory Master, slave for frequencq. amplitude. and modulation

27、step (IEEE-488 Interface controlled) Fluorescent display, 5 %-inches high, rack mountable (with optional kit) 1-5. Controller Functions The Controller microprocessor controls all operator interface functions, performs background operations such as status checks, and updates (strobes) the front panel

28、 displays. Whether you are using local control with the front panel. or remote control with the IEEE-488 Interface. the microprocessor provides self test and diagnostic capability. Economical instrument performance is achieved by using software compensation EPROMs and accuracy-enhancement circuitry.

29、 1-6. LOCAL CONTROL The value of the basic parameters of the Generator, i.e. amplitude. frequency. or modulation can be controlled in three ways: Direct numeric entry Incrementing or decrementing the bright digit Step-up or step-down entry where the step size can be operator programmed Other control

30、s provide selection of the POWER ONIOFF, R F OUTPUT ON/OFF, MODULATION ONIOFF, internallexternal frequency reference, and STATUS. 1-7. DISPLAY FIELD The programmed values of modulation, frequency, and amplitude are displayed in the three display fields. When in the deviation meter mode, the measured

31、 deviation, frequency, and detector status are displayed in the three display fields. 1-8. REMOTE-CONTROL PROGRAMMING The IEEE-488 Interface allows the Generator to be remotely controlled with any IEEE-488 bus controller. The instrument can also be used on the IEEE-488 bus without a controller in a

32、listen-only or talk-only mode by selecting the appropriate Generator rear panel IEEE-488 switch settings. MicroManuals MicroManuals MicroManuals MicroManuals INTRODUCTION AND SPECIFICATIONS All instrument controls can be remotely controlled except the POWER ON/OFF and the rear panel REF INTI EXT swi

33、tches. The IEEE-488 Interface provides additional commands not available with local control, such as data transfer and individual control of internal I/ 0 control bits. The IEEE-488 Interface allows two Generators to track amplitude, frequency, or modulation in a masterlslave configuration when usin

34、g the front panel step-up and step-down entries on one of the instruments. For instance, frequency tracking is convenient for tests involving mixers, and amplitude tracking is useful for two-tone intermodulation testing. 1-9. Frequency The specified frequency range is 0.01 to 520 MHz. The frequency

35、is synthesized from a 1n-MU7 r f r n r 9 n A nrnrr;Aec Q n n n l t n l t r o r n 1 n l t ; n n nf In U7 n.11- tho n-t;.-n C1-nmlnmn., A V LIL L I L I L . L L . L L L . L . UIV y v vuro CIA, V U L U C ICOVIULIVII VI 1 I L . V V L I LIIL CIILIIL I I L U L I I L range. The relative frequency mode allows the frequency to be programmed in relation to a center frequency or an offset frequency. This is convenient for testingfilters and mixers. The output frequency stability and accuracy depends on the reference, whether that reference is internal or external. 1-1 0. Reference The i