1、Service-Manual 3 - D i g i t L C R - M e t e r H M 8 0 1 8 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by

2、 HAMEG is based on the actual generic- and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industria

3、l environment have been used. The measuring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and con

4、ditions regarding emission and immunity should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length,

5、the maximum cable length of a dataline must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables

6、HZ72S and HZ72L from HAMEG are suitable. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside building

7、s. Signal lines must screened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi el

8、ds, even with careful setup of the measuring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in indiv

9、idual cases. HAMEG Instruments GmbH KONFORMITTSERKLRUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACIN DE CONFORMIDAD Hersteller / Manufacturer / Fabricant / Fabricante: HAMEG Instruments GmbH Industriestrae 6 D-63533 Mainhausen Die HAMEG Instruments GmbH bescheinigt die Konformitt f

10、r das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit HAMEG Instruments GmbH certifi ca la conformidad para el producto Bezeichnung: LCR-Meter Product name: LCR meter Designation: LCR mtre Descripcin: Medidor de LC

11、R Typ / Type / Type / Tipo: HM8018 mit / with / avec / con: HM8001-2 Optionen / Options / Options / Opcines: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes / con las siguientes directivas: EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC

12、Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Direc

13、tive des equipements basse tension 73/23/CEE amende par 93/68/CEE Directiva de equipos de baja tensin 73/23/CEE enmendada por 93/68/EWG Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises / Normas armonizadas utilizadas: Sicherheit / Safety / Scurit / Segurid

14、ad: EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994 berspannungskategorie / Overvoltage category / Catgorie de surtension / Categora de sobretensin: II Verschmutzungsgrad / Degree of pollution / Degr de pollution / Nivel de polucin: 2 Elektromagnetische Vertrglichkeit / Electrom

15、agnetic compatibility / Compatibilit lectromagntique / Compatibilidad electromagntica: EN 61326-1/A1: Straussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe / classe B. Strfestigkeit / Immunity / Imunitee / inmunidad: Tabelle / table / tableau / tabla A1. EN 61000

16、-3-2/A14: Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique / emisin de corrientes armnicas: Klasse / Class / Classe / clase D. EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension et du fl icker / fl uctuacion

17、es de tensin y fl icker. Datum / Date / Date / Fecha 22.07.2004 Unterschrift / Signature / Signatur / Signatura G. Hbenett Product Manager RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2 3-Digit LCR-Meter H

18、M8018 4 Specifi cations 5 Alignment procedure 6 Circuit and layout diagrams 7 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8018 Measurement functions: L, C, R 3 -digit display with 2,000 counts, basic accuracy 0.5% 4-wire measurement Max. resolution: 0.1pF, 0.1H, 10m, 0.01S Internal

19、bias for electrolytic capacitors selectable Offset adjustment of cable capacity for the “Kelvin test lead“ AC voltage signal at rear-panel BNC connector proportional to value shown in the display (with Option HO801 only) Mainframe HM8001-2 required for operation Option HZ18 Kelvin test lead Option H

20、O801 Mainframe HM8001-2 12 3 - D i g i t L C M e t e r H M 8 0 1 8 12 5 Subject to change without notice Specifications 3 -Digit LC Meter HM8018 Valid at 23 C after a 30 minute warm-up period Operating modes C measurement L measurement Series inductance L, Shunt capacitance C Series resistance R, Pa

21、rallel conductance G Measurement ranges L: 200H-200H (7 ranges) Rs: 20-200k (5 ranges) C: 200pF-200F (7 ranges) G: 20S-200mS (5 ranges) Max. resolution:0.1pF 0.1H 0.01 0.01S Measurement frequencies:(sine wave signal) 160Hz, 1.6kHz, 16kHz ( = 103, 104,105s-1) Measurement voltage:max. 1Vpp Measurement

22、 current:max. 36mA (eff.) Power output to device under test: max. 3.2mW Measurement accuracy:0.5% of reading +(3 digits +0.5pF/0.5H/10m/0.01S) Measurement error resulting from separation of the real and imaginary part 1% at tan1 Display 31/2-digit 7-segment LED display Sampling rate:2 measurements p

23、er second Type of measurement: 2- or 4-wire measurement 12 Miscellaneous Inputs are short-circuit-proof and overvoltage protected up to 100V with a maximum energy consumption of 10mJ (= capacitor 2F, charged to 100V). Polarization voltage for C measurement: 2V Zero point correction for display Compe

24、nsation of probe capacitance (HZ18) AC voltage signal at rear-panel BNC connector proportional to value shown in the display (HM8001 with option HO801) Power supply +5V/200mA (from mainframe):-13V/130mA +13V/130mA ( = 4.5W) Operating temperature:+10C to +40C Max. relative humidity:80% (without conde

25、nsation) Dimensions (W x H x D) (without 22-pole flat plug): 135 x 68 x 228mm Weight:approx. 0.65kg Accessories supplied: Operators Manual Optional accessories: HZ18 Kelvin test lead HM8018E/140705/ce Subject to alterations HAMEG Instruments GmbH Registered Trademark DQS-certified in accordance with

26、 DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)6182 8000 Fax +49(0)6182 800100 A Rohde & Schwarz Company w w w. h a m e g . co m 6 Subject to change without notice Alignment procedure HM8018 Alignment procedure HM8018 Measuring equip

27、ment required: Oscilloscope 20 MHz (e.g. HM303) Frequency counter (e.g. HM8021) Digital Multimeter DMM (e.g. HM8012) Load 100 k 0.1%, Load 1 k 0.1% Capacitor 470 pF (PP or Polysulfon) Capacitor with known value between 10.16 nF 0.1% Presettings: To start the calibration, fi rst adjust the R-trimmer

28、Pro- be comp.“ and Display Zero“ at the front panel to center position. Disconnect all cables of the frontpanel HM8018. 1. Test of oscillator frequency: Connect frequency counter (TI measuring) to testpoint Synchro“. Set LC-Meter to range 2 pF, G“. Adjust period to 6280 ps 25 ps with R111. 2. Adjust

29、ment of measuring frequency: Set LC-Meter to the ranges described below. Adjust period time as following: 2 F VR103 (3) 6283 s 1 s 200 nF VR102 (2) 628.3 s 1 s 200 pF VR101 (1) 62.83 s 1 s 3. Adjust offset (PD): Connect oscilloscope (AC-coupling, max. sensitivity) to TP5 and set LC-Meter to range 20

30、0 nF, G“. Adjust amplitude to minimum with VR106 (6). 4. Adjust offset (Uref): Connect DMM (VDC)to TP5. Set LC-Meter to 200 mH. Adjust VR109 (9) to 0 1 mV. 5. Symmetry: Set LC-Meter to 200nF, G“. Connect resistance 100 k to the banana jacks and the oscilloscope (AC, 10 mV/Div., 0,1 ms/Div.) to TP7.

31、Adjust VR108 (8) for same amplitude. 6. Adjust offset (Vin): Disconnect all cables from the instrument. Set LC-Meter to range 200 nF. G“. Connect DMM (VDC) to TP7. Adjust VR110(10) to 0 1 mV. 7. Range selection und gain: Connect resistance 1 k to the banana jacks. Set LC-Meter to 200 mH. Repeat the

32、following steps several times. a) Set range to Rs“. Adjust the display of LC-Meter to 1000 1 Digit by means of VR105 (5). b) Set range to G“. Adjust the display of LC-Meter to 1000 1 Digit by means of VR401 (21). 8. Adjustment of input capacitance: Connect capacitor 470 pF to banana jacks. Set LC-Me

33、ter to 200 pF, G“. To adjust the input capacitance, it is necessary to close the module housing (a. and b.). a) Connect oscilloscope (AC-coupling) to TP5, with modul cover closed. Pass the cable through holes in the module cover. Reduce amplitude to minimum by means of VR107 (7). b) Connect oscillos

34、cope to TP4 same way as a). Remove ca- pacitor 470 pF. Reduce amplitude to minimum by means of VR111 (11). 9. Range selection C“, L“: Remove all cables from HM8018. Set LC-Meter to 200 pF, C“. Adjust Display Zero“ (front panel) to 0 3 digit on the display of HM8018. a) Connect Kelvin probe HZ18 to K

35、elvin input (5-pin diode jack) and reduce the reading to 0 3 digit via Probe comp.“ on front panel. b) Disconnect HZ18 and connect a known capacitor between 10 nF and 16 nF to the banana jacks. Set LC-Meter range to 20 nF, C“. Adjust VR104 (4) for same reading as value of the capacitor. misaligned a

36、ligned 7 Subject to change without notice Circuit and layout diagrams Mainboard HM8018 8 Subject to change without notice Circuit and layout diagrams 9 Subject to change without notice Circuit and layout diagrams 10 Subject to change without notice Circuit and layout diagrams 11 Subject to change wi

37、thout notice Circuit and layout diagrams 12 Subject to change without notice Circuit and layout diagrams 13 Subject to change without notice Circuit and layout diagrams 14 Subject to change without notice Circuit and layout diagrams 15 Subject to change without notice Circuit and layout diagrams w w

38、 w . h a m e g . d e authorized dealer Oscilloscopes Spectrum Analyzer Power Supplies Modular System 8000 Series Programmable Instruments 8100 Series Subject to change without notice 4S-8018-00E0 / 10-01-2006-gw HAMEG Instruments GmbH HAMEG Instruments GmbH Industriestrae 6 A Rohde & Schwarz Company D-63533 Mainhausen registered trademark Tel +49 (0) 61 82 800-0 DQS-Certifi cation: DIN EN ISO 9001:2000 Fax +49 (0) 61 82 800-100 Reg.-Nr.: 071040 QM saleshameg.de 4S-8014-00E0