《Hameg hm8030 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg hm8030 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service-Manual F u n c t i o n G e n e r a t o r H M 8 0 3 0 - 6 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic-
2、and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been used. The measu
3、ring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emission and immunity
4、 should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable length of a dataline
5、must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAMEG are suitable
6、. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings. Signal lines must screened (coaxial
7、cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the meas
8、uring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in individual cases. HAMEG Instruments GmbH Gen
9、eral information regarding the CE marking Sicherheit / Safety / Scurit: EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994 EN 61010-1/A2: 1995 / IEC 1010-1/A2: 1995 / VDE 0411 Teil 1/A1: 1996-05 berspannungskategorie / Overvoltage category / Catgorie de surtension: II Verschmutzung
10、sgrad / Degree of pollution / Degr de pollution: 2 Elektromagnetische Vertrglichkeit / Electromagnetic compatibility / Compatibilit lectromagntique EN 61326-1/A1 Straussendung / Radiation / Emission: Tabelle / table / tableau 4, Klasse / Class / Classe B. Strfestigkeit / Immunity / Imunitee: Tabelle
11、 / table / tableau A1. EN 61000-3-2/A14 Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique: Klasse / Class / Classe D. EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension et du fl icker. Datum/Date/Date 22.07.20
12、04 Unterschrift / Signature /Signatur Manuel Roth Manager Hersteller HAMEG Instruments GmbH KONFORMITTSERKLRUNG Manufacturer Industriestrae 6 DECLARATION OF CONFORMITY Fabricant D-63533 Mainhausen DECLARATION DE CONFORMITE Die HAMEG Instruments GmbH bescheinigt die Konformitt fr das Produkt The HAME
13、G Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit Bezeichnung / Product name / Designation: Funktionsgenerator Function generator Gnrateur de fonctions Typ / Type / Type: HM8030-6 mit / with / avec: HM8001-2 Optionen / Options / Opt
14、ions: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Niederspannungsrichtlini
15、e 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Directive des equipements basse tension 73/23/CEE amende par 93/68/CEE Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises RadioFans.CN 收音机爱 好者资料库 3 Subject to c
16、hange without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2 Function Generator HM8030-6 4 Specifi cations 5 Control elements 6 Adjustment 7 Circuit and layout diagrams 9 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8030-6 1 0 M H z F u n c
17、t i o n G e n e r a t o r H M 8 0 3 0 - 6 Frequency range 50mHz to 10MHz High signal purity and amplitude stability Distortion factor 0.5% up to 1 MHz Output voltage 20Vpp(10Vppinto 50) Surge- and short-circuit-proof output Rise and fall time typ. 15 ns Internal and external sweep Pulse width adjust
18、ment Highly accurate digital frequency display Mainframe HM8001-2 required for operation HZ20 Connector BNC to 4mm socket Option HO801 HZ33, HZ34 Test cable BNC/BNC 5 Subject to change without notice Specifications Accessories supplied: Operators Manual Optional accessories: HZ33/HZ34 BNC Test Cable
19、, HZ22 50 feed-through terminal, HZ10 Silicone test leads 10 MHz Function Generator HM8030-6 Valid at 23 C after a 30 minute warm-up period Operating modes Sine, square, triangle, pulse; free running, internal sweep or external frequency modulation, with or without DC offset Frequency ranges 0.05Hz
20、to 10MHz in 8 ranges, variable: x 0.09 to x 1.1 (12:1) Frequency drift:0.5%/hr or 0.8%/24hrs. at constant ambient temperature Waveform characteristics Sine wave distortion 0.05Hz to 1MHz:max. 0.5% 1MHz to 10MHz:max. 5% Square wave rise time:typ. 15ns Overshoot:5% (for termination into 50) Triangle n
21、on-linearity:1% (to 100kHz) Displays Frequency:5-digit, 7-segment LED, each 8 x 5mm Accuracy: up to 5Hz: (1% + 3 digits) 5Hz to 10MHz: (5x10-5+ 1 digit) LED indicators for mHz, Hz, kHz and sec Outputs Signal output:short-circuit proof, protected against ext. voltage up to 45VDCmax. (30sec.) Impedanc
22、e:50 Output voltage:10Vppinto 50 load; 20Vpp (open circuit) Attenuation:max. 60dB 2 attenuators:each 20dB 0.2dB Variable:0 to 20dB Amplitude error:(sine wave/triangle) 0.05Hz to 0.5MHz:max. 0.2dB 0.5MHz to 10MHz:max. 0.5dB DC offset:variable (on/off, except pulse function) into 50 load:max. 2.5V in
23、open circuit:max. 5V Trigger output:square wave synchronous to signal output, approx. +5V/TTL FM input (VCF, BNC connector on rear panel of HM8001-2 and option HO801) Frequency deviation:approx. 1 : 100 Input impedance:6k II25pF Input voltage:max. 30 V Internal sweep Sweep speed:20ms to 15s Sweep ra
24、nge:approx. 1:100 Miscellaneous Power supply+5V/200mA (from mainframe):+16V/300mA -16V/250mA (=9.8W). Operating temperature:+10C to +40C Max. relative humidity:80% (without condensation) Dimensions (W x H x D) (without 22-pole flat plug): 135 x 68 x 228mm Weight:approx. 0.80kg HM8030-6E/140705/ce Su
25、bject to alterations HAMEG Instruments GmbH Registered Trademark DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)6182 8000 Fax +49(0)6182 800100 A Rohde & Schwarz Company w w w. h a m e g . co m 6 Subje
26、ct to change without notice Control elements 10 MHz FUNCTION GENERATOR HM8030-6 Instruments FREQUENCY SWEEP MADE IN GERMANY 50 mHz10 MHz 50 OUTP. max. 20Vpp -20 dB-20 dB -5 V +5V 10% 90% ON START STOP TIME min. max. AMPLITUDE TRIG. OUTP. (TTL) ! s kHz Hz mHz FUNCTION ATTENUATOR OFFSET OFF 1234567891
27、011 12 Control elements DISPLAY (7 segment LED) 5-digit frequency meter. LED indicators for mHz, Hz, kHz and s SWEEP (push button) and SWEEP- Indication (LEDs) Button activates internal sweep generator. The LEDs indi- cate the function chosen with the SWEEP-Button. Settings are changed with or . FRE
28、QUENCY (adjustment knob) Continuous and linear frequency fi ne ad-justment, with the setting range from 0.09 to 1.1 (approx 0.045 to 1.1 in 10 MHz- range) overlapping the ranges selected with FREQUENCY (2 pushbuttons) Frequency range selection from 50 mHz to 10 MHz in 8 de- cade steps. (LED s) Indic
29、ation of selected function. FUNCTION (pushbutton) Mode selection: Triangle, Sine, Square, Pulse and Off. TRIGGER OUTPUT (BNC connector) This short-circuit-proof output supplies a square signal in synchronism with the output signal. It is TTL compatible and has a duty-factor of approx. 50%. OFFSET (a
30、djustment knob) Adjustment of the positive or negative offset voltage. This DC voltage can be super-imposed on the output signal. The max. offset voltage is 5V (o.c.) or 2.5V respectively when terminated into 50. The offset voltage is available to all functions except for pulse and activated by . In
31、 operation mode OFF (no function activated) it can be used separatey. In pulse mode the pulse width is set with this control from 10% to 90%. ON (pushbutton) Activates the offset function except in pulse mode. If the ON-button is pushed in pulse mode, pulse width is set with the control from 10% to
32、90%. In OFF-position the fi xed pulse width amounts to 50%. 50 OUTPUT (BNC connector) Short-circuit proof signal output of the generator. The output impedance is 50 and the max. output amplitude is 20 Vpp (o.c.) or 10 Vpp respectively when terminated into 50. 20dB, 20bB (pushbutton) Two fi xed atten
33、uators, 20dB each. They can be used se- parately. When both pushbuttons are activated, a total at- tenuation of 40dB results. Including the amplitude control , the max. attenuation amounts to 60dB (factor 1000). AMPLITUDE (adjustment knob) Continuous adjustment of the output ampli-tude from 0 to 20d
34、B terminated into 50. 7 Subject to change without notice Adjustment Adjustment Please observe the correct sequence of steps! Measuring equipment required: Digital Multimeter ( HM8012 or similar) Frequency counter (HM8021 or similar) Distortion meter (HM8027 or similar) Oscilloscope (HM1507 or simila
35、r) 1) Turning service mode on a) For activating service mode push both buttons 50mHz“ and 10MHz“ simultaneously and switch on the HM8030. b) If the EPROM is empty or if the HM8030 is new, the dis- play will show E“, otherwise F 3.1“. Push button FUNC- TION“. c) If the display shows XXX3“ (X = any fi
36、 gure, fi gure 3 blinking), turn off the instrument. 2) Switches and controls These settings must be kept constant during the whole ad- justment procedure! a) Open the top cover of the instrument. b) Set OFFSET control to center position. c) Button OFFSET deactivated. d) Set AMPLITUDE control the ri
37、ght stop. e) Buttons ATTENUATOR deactivated. f) Push button SWEEP as often as needed to extinguish the START, STOP and TIME LEDs. 3) Internal triangle generator a) Set HM8030 to triangle function with f = 5250 Hz. b) Connect HM8012 (measuring range: 500 mVDC) with a probe (with the low pass fi lter
38、shown) at PT100. c) Adjust 0 mV 1 mV with VR103. d) Connect HM8012 (measuring range: 500 mVAC) with a probe (without low pass fi lter) at PT100. e) Adjust 577,3 mV 1 mV with VR102. f) As the settings are interacting, repeat steps b) to e) as often as is necessary for an optimum result. 4) Duty cycle
39、 1 a) Connect HM8021 (function: pulse) to OUT. b) Set HM8030 to square function with f = 52,50 kHz. c) Adjust VR101 so that the positive pulse width is equal to the negative pulse width. d) Set HM8030 to square function with f = 4,75 kHz . e) Adjust VR104 so that the positive pulse width is equal to
40、 the negative pulse width. f) As the settings are interacting, repeat steps b) to e) as often as is necessary for an optimum result. 5) Duty cycle 2 a) Connect HM8021 (function: pulse) to OUT. b) Set HM8030 to square function with f = 475 Hz. c) Adjust VR106 so that the positive pulse width is equal
41、 to the negative pulse width. 6) OUTPUT Offset a) Connect HM8012 (measuring range: 500 mVDC) with low pass fi lter to OUT. b) Set HM8030 to triangle function with f = 5250 Hz. c) Adjust 0 mV 1 mV with VR111. 7) Distortion a) Connect HM8027 (20k Frequency Range) to OUT. b) Set HM8030 to sine function
42、 with f = 5250 Hz. c) Set HM8027 (settings: 100% CAL) with the blue control to 100, than switch to 10%. d) Adjust the distortion factor to less than 0.3% by alterna- tely adjusting VR108 and VR109. e) If this adjustment is not possible, return to step 4) be- cause the duty cycle was not correctly ad
43、justed. 8) Square 1 a) Connect oscilloscope HM1507 (settings: 1V/div, 100s/ div) with 50 to OUT. b) Set HM8030 to triangle function with f = 5250 Hz. c) Adjust VAR on the oscilloscope so that the amplitude of the signal equals to 6 div. d) Set HM8030 to square function with f = 5250 Hz. e) Adjust VR
44、105, VR107 and VR110 so that the amplitude of the square signal amounts to 6 div. f) Repeat step e) with f = 52,5 kHz. 9) Square 2 a) Connect oscilloscope HM1507 (settings: 1V/div, 50ns/div) with a 50 load at OUT. b) Set HM8030 to square function with f = 5250kHz. c) Adjust VC102 and VC104 so that t
45、he amplitude of the square signal equals to 6 div. 10) Triangle a) Connect oscilloscope HM1507 (settings: 1V/div, 50ns/div) with a 50 load at OUT. b) Set HM8030 to triangle function with f = 7000 kHz. c) Adjust VC101 so that the amplitude of the triangle signal equals to 6 div. 11) Duty cycle of pul
46、se a) Connect HM8021 (function: pulse) to OUT. b) Set HM8030 to pulse function with f = 5250 Hz. c) Adjust VR1 so that the positive pulse width is equal to the negative pulse width. 8 Subject to change without notice Adjustment Adjustment HM8030-6 30. November 2004 . VR103 3) Internal triangle gener
47、ator a)HM8030 - triangle function - f = 5250Hz. b)HM 8012 (500mVDC) with a probe (with low- pass filter) at PT100. c) Adjust 0mV? 1mV with VR103. d)Connect HM8012 (500mVAC) with a probe (without lowpass filter) at PT100. e)Adjust 577,3mV? 1mV with VR102. f)As settings are interacting, repeat steps b
48、) - e) as often as is necessary for an optimum result. VR102 2) Switches and controls - These settings must be kept constant during the whole adjustment! a)Open the top cover of the instrument. b)Set OFFSET control to center position. c)Button OFFSET deactivated. d)Set AMPLITUDE control to the right
49、 stop. e)Buttons ATTENUATOR deactivated. f)Push button SWEEP as often as is needed to extinguish the START, STOP and TIME LEDs. 1)Turning service mode on a)For activating service mode push both buttons 50mHz“ and 10MHz“ simultaneously and switch on the HM8030. a)If the EPROM is empty or if the HM8030 is new, the display will show E“, otherwise F 3.1“. Push button FUNC- TION“. If the display shows XXX3“ (X = any figure, figure 3 blinking), turn off the instrument. 4) Duty