1、Fully Featured TIA/EIA-136 (TDMA) Test Solution The IFR-1900 CSA provides you with the industry?s only accepted test solution for TIA/EIA-136 analysis, including critical adjacent power measurements and power measurements down to -40 dBm, which allows the user to test the base station without taking
2、 it off-line. It is capable of performing the critical dual-mode analog/digital authentication and protocol compliance tests for TIA/EIA-136 dual mode mobiles. As for flexibility, the IFR-1900 CSA provides the capability to perform both mobile and base station conformance testing. And with the VSELP
3、 and ACELP vocoder technology as standard features, the IFR-1900 CSA can handle today?s latest technology. The IFR-1900 CSA comes with a wide array of application software options. The AC1036 Protocol Conformance Test Software provides an excellent way to verify software conformance of TIA/EIA-136 m
4、obiles. Other applications software supports automated tests for the most widely used base station applications. AMPS Solutions Engineered to be a true dual-mode test solution, the IFR-1900 CSA also incorporates AMPS and NAMPS mobile and base station compliance test features. Full AMPS testing modes
5、 are available with the IFR-1900 CSA Automatic test routines and user defined print outs enhance manual mode testing for both mobiles and base stations. Open control channel simulations, voice channel signaling, home/roam condition, home SID, SAT, DSAT, DST, DCC, SINAD reference points, RF power win
6、dows, and other AMPS/NAMPS functions and signaling routines allow complete AMPS and NAMPS system testing. A Full Complement of Service Monitor Functions to 2 GHz. The IFR-1900 CSA gives you full frequency domain analysis to 2 GHz with a fully featured spectrum analyzer and tracking generator built-i
7、n. The IFR-1900 CSA also offers a full complement of standard service monitor features including a full span digitized oscilloscope to 1 MHz, DVM and SINAD functions, frequency and channel tables, selectable IF filters, and a wide variety of displays. The IFR-1900 CSA gives you full featured service
8、 monitor functions IFR-1900 CSA UWC-136 Digital PCS Radio Test Set Engineered for maximum performance, the IFR-1900 CSA is an all in one PCS solution for today?s dual band/dual mode mobile and base station equipment Wireless - Radio Test Sets The industry accepted simulator for TIA/EIA-136 conforman
9、ce testing Tri-Band, 400/800 MHz and 1900 MHz PCS test capable Comprehensive TIA/EIA-136 conformance testing Analog and digital authentication compliance testing option TIA/EIA-136 hyperband handoff Fully automated remote testing ability with RS-232 or IEEE-488 (GPIB) interfaces Intuitive test set u
10、p screens for easy ?Guided? user testing VSELP and ACELP vocoder functions allow verification of voice quality Full featured 2 GHz service monitor with spectrum analyzer and tracking generator Standard constellation IQ display for quick assessment of digital mobile or base station transmitter modula
11、tion IFR-1900 CSA1 RadioFans.CN 收音机爱 好者资料库 In addition to the 2 GHz RF generator, the IFR-1900 CSA also provides full audio/data generator capabilities, full level control and measurement facilities and precision power control features for enhanced sensitivity and high accuracy testing needs. Analog
12、 paging encoding/decoding, DTMF, tone coded squelch, digital squelch, AM modulation/demodulation along with two separate AF generators and cross band duplex gives added test versatility in a variety of wireless systems. Software Options Make Complex Testing Simple As with every IFR test set, you get
13、 the advantage of IFR applications engineering support. Our comprehensive portfolio of application software options are designed to automate and expand the functionality of your instrument. Plus, on-going software support means that you can easily upgrade your IFR-1900 CSA when test and service requ
14、irements change. AC1009W - EasySpanTMis a Windows- based software utility which extracts spectrum analyzer and tracking generator traces from the IFR-1900 CSA. AC1017 - AutoCell-Series II is a comprehensive program for FCC compliance testing of Lucent Series II cell sites. AC1019 - EasySweepTMis a s
15、wept measurement utility designed to test antennas and transmission lines. AC1020D - AutoCell NTD provides automated testing of Northern Telecom cell sites. AC1021 - CellScanTMcellular utility software simplifies combiner alignment, monitoring RF levels and base stations on DAMPS, NT400 or PCS cellu
16、lar channel sets. AC1027 - AutoCell-882/884 is an autotest program for performing acceptance tests on Ericsson 884/882/882D/882M/882DM base stations. EasySpan Software Dynamic IQ Constellation Display Simplifies Analysis The IFR-1900 CSA provides you with a dynamic constellation display for precise
17、RF modulation analysis of DQPSK digitally modulated waveforms from 10 MHz to 2010 MHz. This unique IFR-1900 CSA feature gives a near real time display for testing and troubleshooting, an ability that points out the cause of the trouble in digital radios. IQ Constellation display allows for comprehen
18、sive digital modulation testing Complex Functionality Made Easy Even with its elaborate capabilities, the IFR-1900 CSA was developed to execute complex tests simply and with minimal operator training. Using field-proven front panel and user man-machine interfaces, the IFR-1900 CSA gives you the perf
19、ormance and ease-of-use features that reduces your testing and training time. Its test macro command programming language (TMAC) can be easily configured to perform automatic base station testing and remote terminal, single and multi- mode, single and multiband equipment. This powerful capability al
20、lows you to create and save simple ?one button? test routines for future use. This flexibility means you can create and execute complex and repeatable routines no matter what your level of expertise. A new color VGA display gives IFR-1900 CSA users vivid screen clarity. Extensive use of softkeys red
21、uces your complex cellular / PCS parametric and protocol tests to fast, simple and manageable routines. Specification (T/R) AND DUPLEX CONNECTOR Frequency Range 10 MHz to 2010 MHz Resolution 100 Hz Accuracy Same as Master Oscillator Range -127 dBm to + 10 dBm into 50 (T/R Connector: -30 dBm maximum
22、with reverse power present) Resolution 0.1 dB Accuracy 1.5 dB (-110 dBm) Duplex Connector Input Protection Alarm sounds when level exceeds +20 dBm. EXTERNAL Generator IF Output Frequency Range 88 MHz to 90 MHz Level Range -30 dBm to +25 dBm into 50 Residual FM 10 Hz RMS SSB Phase Noise -94 dBc/Hz (2
23、0 kHz Offset) Residual AM 0.3% RMS (50 Hz to 15 kHz BW) Non-Harmonics 20 kHz Dev, 1 kHz rate) Resolution 100 Hz Modulation Rate 1 kHz to 10 kHz - 5% accuracy Waveforms Sine, Square, Triangle INTERNAL PHASE/QUADRATURE (IQ) RF Ranges 10 MHz to 2010 MHz IQ Error Vector Magnitude 5% from ideal DQPSK wav
24、eform (TIA/EIA-136) IQ Origin Offset 2 kHz Accuracy 0.1% Waveshapes Sinewave, Square, Triangle, Ramp, Pulse Frequency Range 10 Hz to 200 kHz (in 4 decade ranges) Accuracy Same as Master Oscillator Resolution 0.1 Hz (10 Hz to 2 kHz) 1 Hz (2 kHz to 20 kHz) 10 Hz (20 kHz to 40 kHz) Input Waveform Sine
25、or Square External Level 0.5 VRMS to 30 VRMS (SINAD/BER input) 0.1 VRMS to 3.5 VRMS (EXT MOD input) Audio Frequency Counter AF Signal Generators Modulation RF Signal Generator IFR-1900 CSA IFR-1900 CSA2 RadioFans.CN 收音机爱 好者资料库 Frequency Range 10 MHz to 2010 MHz Accuracy Same as Master Oscillator Res
26、olution 1 Hz (fc 20 MHz) Minimum Level -60 dBm (ANT connector) Frequency Digital Meter Range 0 Hz to 150 kHz Bar Graph Meter Range 0 to 100 kHz (in 4 decade ranges) Accuracy Same as Master Oscillator LSD Resolution 1 Hz (1 Hz to 10 kHz) 10 Hz (10 kHz to 150 kHz) Minimum Level -60 dBm (ANT Input Port
27、) Frequency Range 100 MHz to 2010 MHz Input Level 0.05 mW to 50 W RMS (900 MHz, 1?2?5 sequence, 4 decade) Resolution 1 % Accuracy 6% (5 W and 50 W, at Typical Operational Ambient Temperature) LOW LEVEL POWER METER Frequency Range Same as standard RF power meter Input level -40 dBm to -10 dBm Accurac
28、y 12% typical Frequency Range 10 MHz to 2010 MHz Sensitivity 20 kHz ranges) Accuracy 5 % 2 counts + source residual FM (300 kHz IF, 5 Rad) Carrier Range 100 MHz to 2010 MHz Minimum Carrier Level -60 dBm (ANT Input Port) Modulation Range 1 % to 90 % Resolution 1 % Accuracy 5 % of full scale 1 count +
29、 source residual AM (30 % to 90 %) Carrier Range 100 MHz to 2010 MHz Minimum Carrier Level -60 dBm (ANT Input Port) Distortion Range 0.1 % to 20 % Resolution 0.1 % Accuracy 0.5 % distortion 1 count (1 % to 10 %) 2 % distortion 1 count (10 %) Signal Frequency 700 Hz to 1.4 kHz Signal Level 0.1 VRMS t
30、o 30 VRMS (SINAD/BER input) Input Range NT 400 Channels Cellular 800 MHz Channels PCS 1900 MHz Channels Minimum Carrier Level -60 dBm (ANT connector) EVM Range 0 to 100 % EVM Resolution 0.01 % Meter Residual EVM 2 % indication Accuracy 3.0% indication, 1 LSD + meter residual EVM Range 3 dB to 30 dB
31、Resolution 0.1 dB Accuracy 1 dB 1 count (at 12 dB SINAD) Signal Frequency 700 Hz to 1.4 kHz Signal Level 0.1 VRMS to 30 VRMS (SINAD/BER input) VOLTMETER (DC/AC) Ranges 200 mV to 200 V (full scale, decade sequence, 150 , 600 , 1 M selectable) Maximum Input 1000 VDC 500 VAC Resolution 3.5 digit (maxim
32、um resolution 0.1 mV on 200 mV range) Accuracy 5% of full scale 1 count (AC, where ACV*kHz 140) 1% of full scale 1 count (DC) Frequency DC, 50 Hz to 20 kHz Input Impedance 1 M (5%) 150 (5%) 600 (5%) OHMMETER Ranges 200 to 20 M (full scale, decade sequence) Resolution 3.5 digit (maximum resolution 0.
33、1 on 200 range) Accuracy 5% or 0.1 (1 count) CURRENT METER (DC/AC) Ranges 20 mA to 2 A (full scale, decade sequence, 20 A maximum when using external shunt) Resolution 3.5 digit (maximum resolution 0.01 mA on 20 mA range) Accuracy 5 % or 0.1 mA 1 count Vertical BW 1 MHz (-3 dB) Input Ranges 1 mV / D
34、iv to 50 V / Div (1-2-5 sequence, 8 divisions) Max Input Vertical 200 V Peak Accuracy Vertical 5% of full scale 10% of full scale (1 mV and 2 mV ranges) Resolution Vertical Full Scale / 256 Coupling Vertical AC, DC, GND Horizontal Sweep Rate 1 ?Sec / Div to 100 msec / Div (1-2-5 sequence, 10 divisio
35、ns) Accuracy Horizontal 1 % of Full Scale Resolution Horizontal Full Scale / 400 External Input Impedance Horizontal 1 M (shunted by 27 pF nominal) Internal Signal Routing 425 kHz IF Demod Audio Function Generator SINAD/BER RF Power EXT MOD Range 10 MHz to 2010 MHz Frequency Span Range 1 kHz/Div to
36、100 MHz/Div plus Zero Scan (10 divisions in a 1-2-5 sequence) Accuracy 5% of Span Width Reference Accuracy See Master Oscillator Display Log, 10 dB/Div and 2 dB/Div Vertical Resolution Full Scale/256 Displayed Range (Dynamic) 60 dB (0 dB Attenuation, Span 1 MHz/Div) Bandwidth Switching Error 2 dB (5
37、 kHz/Div thru 1 MHz/Div) 3 dB (1 MHz/Div) Spectrum Analyzer Oscilloscope Digital Multimeter SINAD Meter Error Vector Magnitude (EVM) Meter Distortion Meter AM Modulation Meter PM Deviation Meter FM Deviation Meter Receiver RF Power Meter RF Frequency Error Meter RF Counter IFR-1900 CSA Wireless - Ra
38、dio test Sets IFR-1900 CSA3 RadioFans.CN 收音机爱 好者资料库 Overall Accuracy 4 dB (10 MHz to 400 MHz) (normalized) 5 dB (400 MHz to 2010 MHz) (normalized) 2 dB Log Linearity Input Attenuator 0 dB, 20 dB, 40 dB (User selectable, ANT Input Port) 40 dB, 60 dB, 80 dB, (User selectable Pwr 2 W, T/R Port) Range 1
39、x10-1to 1x10-5 Data Rates 75, 150, 300, 600, 1200, 2400, 4800 bps & 16 kbps Data Pattern Size 100 to 100,000 bits Data Pattern Type Random, Fixed and User Defined IEEE 488.1-1987 Internally Assigned GPIB Addresses System Control Processor (GPIB Address=4) TDMA Control Processor (GPIB Address=5) RS-2
40、32 (Asynchronous) SCSI-1 External Video Port Operation Mode VGA Compliant Frequency Reference Ports BNC Input for External 10 MHz Sync BNC Output of Internal 10 MHz Sync Dedicated Printer Port 25-Pin D-Sub, Centronics Compatible IQ Output Interface BNC Connector TDMA Timeslot Sync BNC Connector Freq
41、uency Standard 10 MHz (Nominal) Temp Stability 0.01 ppm (0 to 50?C) Dimensions 188 mm (7.4 in) H, 478 mm (18.8 in) W, 635 mm (25 in) D (with bail handle and front panel cover in place) Weight Less than 21.8 kg (48 lb) Operating Temperature Range 0 to 50?C POWER REQUIREMENTS Line 105 - 130 to 210 - 2
42、60 VAC 50 to 60 Hz 200 W Maximum DISPLAY Type Color, Active Matrix LCD Size 96 mm (3.8 in) wide, 86 mm (3.4 in) high Resolution 640 pixel x 480 pixels. When ordering please quote the full ordering number information. Ordering NumbersVersions 1900IFR-1900 CSA Service Monitor 1900-CIFR-1900 CSA Servic
43、e Monitor with Certificate of Calibration Accessories AC510Paging Encoder for Flex, GSC and NEC D3 AC1009WEasySpan for Windows (Waveform Transfer) AC1017AutoCell-Series II (Lucent Series II) AC1019EasySweep (Swept Antenna Measurements) AC1020DAutoCell-NTD (Northern Telecom Cell Sites) AC1021CellScan
44、 AC1027AutoCell-882/884 (Ericsson) AC1036TIA/EIA-136 Conformance Software AC1048SSD Update & Authentication Test AC1201Telescoping Antenna AC3403TMAC Users Manual AC4103Return Loss Bridge Kit(5 MHz to 2 GHz) (Includes AC1019) AC8645Microphone AC9153Soft Padded Carrying Case EasySpan, EasySweep, Auto
45、Cell and CellScan are copyrighted by IFR Systems, Inc. Versions & Accessories General Characteristics Master Oscillator Input/Output (I/O) Bit Error Meter (BER) IFR Ltd, Longacres House, Norton Green Road, Stevenage, Herts SG1 2BA, United Kingdom. E-mail: infoifrinternational.co.uk Tel: +44 (0) 1438
46、 742200 Freephone UK: 0800 282 388 Fax: +44 (0) 1438 727601 IFR Americas, Inc., 10200 West York Street, Wichita, Kansas 67215-8999, USA. E-mail: Tel: +1 316 522 4981 Toll Free USA: 1 800 835 2352 Fax: +1 316 522 1360 As we are always seeking to improve our products, the information in this document
47、gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent Company IFR Systems, Inc. IFR Ltd. 1999. IFR-1900 CSA Part no. 46891-028 Revision AIFR-1900 CSA4