KEI 7002 Instruction 电路图.pdf

上传人:cc518 文档编号:202208 上传时间:2025-03-08 格式:PDF 页数:382 大小:4.72MB
下载 相关 举报
KEI 7002 Instruction 电路图.pdf_第1页
第1页 / 共382页
KEI 7002 Instruction 电路图.pdf_第2页
第2页 / 共382页
KEI 7002 Instruction 电路图.pdf_第3页
第3页 / 共382页
亲,该文档总共382页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《KEI 7002 Instruction 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI 7002 Instruction 电路图.pdf(382页珍藏版)》请在收音机爱好者资料库上搜索。

1、Model 7002Switch System Instruction Manual A G R E A T E RM E A S U R E O F C O N F I D E N C E RadioFans.CN 收音机爱 好者资料库 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 year from date of shipment. Keithley Instruments, In

2、c. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, write or call

3、your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs will be made and the product returned, transportation prepaid. Re

4、paired or replaced products are warranted for the balance of the original warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modifi cation without Keithleys express written consent, or misuse of any product or part. This warran

5、ty also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FIT

6、NESS FOR A PARTICULAR USE. THE REMEDIES PRO- VIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE

7、EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIM- ITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PERSON, OR DAMAGE TO PROPERTY. Keithley Instruments, I

8、nc. 28775 Aurora Road Cleveland, Ohio 44139 440-248-0400 Fax: 440-248-6168 1-888-KEITHLEY (534-8453) Sales Offi ces:BELGIUM:Bergensesteenweg 709 B-1600 Sint-Pieters-Leeuw 02-363 00 40 Fax: 02/363 00 64 CHINA:Yuan Chen Xin Building, Room 705 12 Yumin Road, Dewai, Madian Beijing 100029 8610-6202-2886

9、Fax: 8610-6202-2892 FINLAND:Tietjntie 2 02130 Espoo Phone: 09-54 75 08 10 Fax: 09-25 10 51 00 FRANCE:3, alle des Garays 91127 Palaiseau Cdex 01-64 53 20 20 Fax: 01-60 11 77 26 GERMANY:Landsberger Strasse 65 82110 Germering 089/84 93 07-40 Fax: 089/84 93 07-34 GREAT BRITAIN:Unit 2 Commerce Park, Brun

10、el Road Theale Berkshire RG7 4AB 0118 929 7500 Fax: 0118 929 7519 INDIA:Flat 2B, Willocrissa 14, Rest House Crescent Bangalore 560 001 91-80-509-1320/21 Fax: 91-80-509-1322 ITALY:Viale San Gimignano, 38 20146 Milano 02-48 39 16 01 Fax: 02-48 30 22 74 KOREA:FL., URI Building 2-14 Yangjae-Dong Seocho-

11、Gu, Seoul 137-130 82-2-574-7778 Fax: 82-2-574-7838 NETHERLANDS:Postbus 559 4200 AN Gorinchem 0183-635333 Fax: 0183-630821 SWEDEN:c/o Regus Business Centre Frosundaviks All 15, 4tr 169 70 Solna 08-509 04 679 Fax: 08-655 26 10 SWITZERLAND:Kriesbachstrasse 4 8600 Dbendorf 01-821 94 44 Fax: 01-820 30 81

12、 TAIWAN:1FL., 85 Po Ai Street Hsinchu, Taiwan, R.O.C. 886-3-572-9077 Fax: 886-3-572-9031 Copyright 2001 Keithley Instruments, Inc. Printed in the U.S.A. 11/01 RadioFans.CN 收音机爱 好者资料库 Model 7002 Switch System Instruction Manual 1993, Keithley Instruments, Inc. All rights reserved. Cleveland, Ohio, U.

13、S.A. January 2002, Fourth Printing Document Number: 7002-901-01 Rev. D RadioFans.CN 收音机爱 好者资料库 Manual Print History The print history shown below lists the printing dates of all Revisions and Addenda created for this manual. The Revision Level letter increases alphabetically as the manual undergoes

14、subsequent updates. Addenda, which are released between Revisions, contain important change information that the user should incorporate immediately into the manual. Addenda are numbered sequentially. When a new Revision is created, all Addenda associated with the previous Revision of the manual are

15、 incorporated into the new Revision of the manual. Each new Revi- sion includes a revised copy of this print history page. Revision A (Document Number 7002-901-01).March 1993 Addendum A (Document Number 7002-901-02).June 1993 Revision B (Document Number 7002-901-01).June 1993 Addendum B (Document Nu

16、mber 7002-901-02).April 1995 Addendum B (Document Number 7002-901-03).March 1996 Addendum F (Document Number 7001-901-04).September 1996 Revision C (Document Number 7002-901-01) .September 1998 Revision D (Document Number 7002-901-01).January 2002 All Keithley product names are trademarks or registe

17、red trademarks of Keithley Instruments, Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Safety Precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some in- strum

18、ents and accessories would normally be used with non-haz- ardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualifi ed personnel who recog- nize shock hazards and are familiar with the safety precautions re- quired to avoid possible

19、injury. Read and follow all installation, operation, and maintenance information carefully before using the product. Refer to the manual for complete product specifi cations. If the product is used in a manner not specifi ed, the protection pro- vided by the product may be impaired. The types of pro

20、duct users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifi cations and operating limits, and for en- suring that operators are adequately trained. Operators use the product for its i

21、ntended function. They must be trained in electrical safety procedures and proper use of the instru- ment. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating properly, for example,

22、setting the line voltage or replacing consumable materials. Maintenance procedures are de- scribed in the manual. The procedures explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, a

23、nd perform safe installations and repairs of products. Only properly trained ser- vice personnel may perform installation and service procedures. Keithley products are designed for use with electrical signals that are rated Installation Category I and Installation Category II, as de- scribed in the

24、International Electrotechnical Commission (IEC) Standard IEC 60664. Most measurement, control, and data I/O sig- nals are Installation Category I and must not be directly connected to mains voltage or to voltage sources with high transient over-volt- ages. Installation Category II connections requir

25、e protection for high transient over-voltages often associated with local AC mains connections. Assume all measurement, control, and data I/O con- nections are for connection to Category I sources unless otherwise marked or described in the Manual. Exercise extreme caution when a shock hazard is pre

26、sent. Lethal voltage may be present on cable connector jacks or test fi xtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS, 42.4V peak, or 60VDC are present. A good safety practice is to expect that hazardous voltage is

27、 present in any unknown circuit before measuring. Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operators are pre- vented access and/or insulated from every connection point. In some cases, connections must be exposed to potential

28、 human con- tact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 volts, no conductive part of the circuit may be exposed. For rack mount equipment in which the power cord is not a

29、ccessi- ble, in the event of fi re or other catastrophic failure, the user must provide a separate power disconnect switch. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance limited sources. NEVER connect switching cards directly to AC m

30、ains. When con- necting sources to switching cards, install protective devices to lim- it fault current and voltage to the card. Before operating an instrument, make sure the line cord is connect- ed to a properly grounded power receptacle. Inspect the connecting cables, test leads, and jumpers for

31、possible wear, cracks, or breaks before each use. When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power dis- connect device must be provided, in close proximity to the equip- ment and within easy reach of the operator. For max

32、imum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jump- ers, installing or removing switching cards,

33、 or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the com- mon side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of wi

34、thstanding the voltage being measured. The instrument and accessories must be used in accordance with its specifi cations and operating instructions or the safety of the equip- ment may be impaired. Do not exceed the maximum signal levels of the instruments and ac- cessories, as defi ned in the spec

35、ifi cations and operating informa- tion, and as shown on the instrument or test fi xture panels, or switching card. When fuses are used in a product, replace with same type and rating for continued protection against fi re hazard. Chassis connections must only be used as shield connections for measu

36、ring circuits, NOT as safety earth ground connections. If you are using a test fi xture, keep the lid closed while power is ap- plied to the device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to safety earth ground using the wire recommended in t

37、he user documentation. The symbol on an instrument indicates that the user should re- fer to the operating instructions located in the manual. The symbol on an instrument shows that it can source or mea- sure 1000 volts or more, including the combined effect of normal and common mode voltages. Use s

38、tandard safety precautions to avoid personal contact with these voltages. The WARNING heading in a manual explains dangers that might result in personal injury or death. Always read the associated infor- mation very carefully before performing the indicated procedure. The CAUTION heading in a manual

39、 explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be connected to humans. Before performing any maintenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fi re, replac

40、ement components in mains circuits, including the power transformer, test leads, and input jacks, must be purchased from Keithley Instru- ments. Standard fuses, with applicable national safety approvals, may be used if the rating and type are the same. Other components that are not safety related ma

41、y be purchased from other suppliers as long as they are equivalent to the original component. (Note that se- lected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product.) If you are unsure about the applicability of a replacement component

42、, call a Keithley Instruments offi ce for information. To clean an instrument, use a damp cloth or mild, water based cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a ci

43、rcuit board with no case or chassis (e.g., data acquisition board for installation into a computer) should never require cleaning if handled according to in- structions. If the board becomes contaminated and operation is af- fected, the board should be returned to the factory for proper cleaning/ser

44、vicing. ! 11/01 HW 9/12/01 Rev. C SYSTEM CAPACITY: 10 plug-in cards per mainframe. MEMORY:Battery backed-up storage for 500 switch patterns. SWITCH SETTLING TIME: Automatically selected by the mainframe. For different switchcards, 7002 will be set to the slowest relay settling time. Additional time

45、from 0 to 99999.999 seconds can be added in 1ms increments. TRIGGER SOURCES: External Trigger (TTL-compatible, 600ns minimum pulse, rear panel BNC). IEEE-488 bus (GET, *TRG) Trigger Link Manual (front panel) Internal Timer, programmable from 1.0ms to 99999.999 seconds in 1.0ms increments. STATUS OUT

46、PUT: Channel Ready (TTL-compatible signal, rear panel BNC). Low going pulse (10s typical) issued after relay settling time. SWITCHING SEQUENCE: Break-before-make (programmable). MAINFRAME DIGITAL I/O: 4 open collector outputs (30V maximum, 100mA maximum sink current, 10 output impedance), 1 TTL comp

47、atible input, 1 common, 1+5V. RELAY DRIVE: 3.5A maximum for all 10 card slots. CARD SIZE: 32mm high 114mm wide 272mm long (1 in 4 in 10 in). CARD COMPATIBILITY: Fully compatible with all 7001 cards. ANALOG BACKPLANE SIGNALS: Four 3-pole rows (Hi, Lo, Guard). These signals provide matrix and multiplexer expansion between cards within one mainframe. MAXIMUM VOLTAGE: 250V DC, 250V RMS, 350V AC peak, signal path to signal path or signal path to chassis. MAXIMUM CURRE

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 仪器仪表 > Keithley

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号