1、 EC N E D I FN OC F O E RUSA E M R E TA E R G A m o c . ye lh t ie k . ww w E C N E D I F N O C F O E R U S A E M R E T A E R G A Model 2002 Multimeter Users Manual 2002-900-01 Rev. E / February 2009 Model 2002 Multimeter Users Manual 2002-900-01 Rev. E / February 2009 RadioFans.CN 收音机爱 好者资料库 Model

2、2002 Multimeter Users Manual 2009, Keithley Instruments, Inc. Cleveland, Ohio, U.S.A. All rights reserved. Any unauthorized reproduction, photocopy, or use of the information herein, in whole or in part, without the prior written approval of Keithley Instruments, Inc. is strictly prohibited. TSP, TS

3、P-Link, and TSP-Net are trademarks of Keithley Instruments, Inc. All Keithley Instruments product names are trademarks or registered trademarks of Keithley Instruments, Inc. Other brand names are trademarks or registered trademarks of their respective holders. Document Number: 2002-900-01 Rev. E/ Fe

4、bruary 2009 RadioFans.CN 收音机爱 好者资料库 Safety Precautions 11/07 The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with non-hazardous voltages, there are situations where haza

5、rdous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using the pro

6、duct. Refer to the user documentation for complete product specifications. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. The types of product users are: Responsible body is the individual or group responsible for the use and mainte

7、nance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the inst

8、rument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating properly, for example, setting the line voltage or replacing consumable materials. Maintenance procedures are described in

9、 the user documentation. The procedures explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, perform safe installations, and repair products. Only properly trained service personnel m

10、ay perform installation and service procedures. Keithley Instruments products are designed for use with electrical signals that are rated Measurement Category I and Measurement Category II, as described in the International Electrotechnical Commission (IEC) Standard IEC 60664. Most measurement, cont

11、rol, and data I/O signals are Measurement Category I and must not be directly connected to mains voltage or to voltage sources with high transient over-voltages. Measurement Category II connections require protection for high transient over-voltages often associated with local AC mains connections.

12、Assume all measurement, control, and data I/O connections are for connection to Category I sources unless otherwise marked or described in the user documentation. Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The Ame

13、rican National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS, 42.4V peak, or 60VDC are present. A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring. Operators of this product must be pro

14、tected from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Product operators in these circumstances must be trained to protect thems

15、elves from the risk of electric shock. If the circuit is capable of operating at or above 1000V, no conductive part of the circuit may be exposed. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance-limited sources. NEVER connect switching

16、 cards directly to AC mains. When connecting sources to switching cards, install protective devices to limit fault current and voltage to the card. Before operating an instrument, ensure that the line cord is connected to a properly-grounded power receptacle. Inspect the connecting cables, test lead

17、s, and jumpers for possible wear, cracks, or breaks before each use. RadioFans.CN 收音机爱 好者资料库 When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power disconnect device must be provided in close proximity to the equipment and with

18、in easy reach of the operator. For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, ins

19、talling or removing switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dr

20、y, insulated surface capable of withstanding the voltage being measured. The instrument and accessories must be used in accordance with its specifications and operating instructions, or the safety of the equipment may be impaired. Do not exceed the maximum signal levels of the instruments and access

21、ories, as defined in the specifications and operating information, and as shown on the instrument or test fixture panels, or switching card. When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. Chassis connections must only be used as

22、shield connections for measuring circuits, NOT as safety earth ground connections. If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to safety earth ground using

23、the wire recommended in the user documentation. The symbol on an instrument indicates that the user should refer to the operating instructions located in the user documentation. The symbol on an instrument shows that it can source or measure 1000V or more, including the combined effect of normal and

24、 common mode voltages. Use standard safety precautions to avoid personal contact with these voltages. The symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. The symbol indicates a connection terminal to the equipment frame. If this symbol is on a prod

25、uct, it indicates that mercury is present in the display lamp. Please note that the lamp must be properly disposed of according to federal, state, and local laws. The WARNING heading in the user documentation explains dangers that might result in personal injury or death. Always read the associated

26、information very carefully before performing the indicated procedure. The CAUTION heading in the user documentation explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be connected to humans. Before performing any main

27、tenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fire, replacement components in mains circuits - including the power transformer, test leads, and input jacks - must be purchased from Keithley Instruments. Standard fuses with applicable national s

28、afety approvals may be used if the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through Keithley Instruments to maintain acc

29、uracy and functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley Instruments office for information. To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner di

30、rectly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled according to instructions. If the board becomes c

31、ontaminated and operation is affected, the board should be returned to the factory for proper cleaning/servicing. ! Table of Contents 1General Information 1.1Introduction . 1-1 1.2Features . 1-1 1.3Warranty information . 1-2 1.4Manual addenda . 1-2 1.5Safety symbols and terms . 1-2 1.6Specifications

32、 . 1-2 1.7Inspection . 1-2 1.8Options and accessories . 1-2 2Front Panel Operation 2.1Introduction . 2-1 2.2Power-up . 2-1 2.2.1Line power connections . 2-1 2.2.2Line fuse replacement . 2-2 2.2.3Power-up sequence . 2-2 2.2.4High energy circuit safety precautions . 2-4 2.2.5Power-on default condition

33、s . 2-4 2.2.6Warm-up period . 2-4 2.2.7IEEE-488 primary address . 2-4 2.3Display . 2-4 2.3.1Multiple displays . 2-4 2.3.2Information messages . 2-7 2.3.3Status and error messages . 2-7 2.3.4Navigating menus . 2-9 2.4Functions . 2-9 2.4.1DC and AC voltage . 2-9 2.4.2DC and AC current . 2-23 2.4.3Two and four-wire resistance . 2-28 2.4.4Frequency . 2-32 2.4.5Temperature . 2-33 2.5Range . 2-40 2.5.1Display resolution . 2-40 2.5.2Maximum readings . 2-40 2.5.3Manual ranging . 2-40 2.5.4Autoranging . 2-40 2.6Relative . 2-40 2.6.1Configuring rel . 2-41 2.6.2Enabling rel .