LECROY WS Series Remote Control 电路图.pdf

上传人:cc518 文档编号:202519 上传时间:2025-03-08 格式:PDF 页数:2 大小:239.93KB
下载 相关 举报
LECROY WS Series Remote Control 电路图.pdf_第1页
第1页 / 共2页
LECROY WS Series Remote Control 电路图.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

《LECROY WS Series Remote Control 电路图.pdf》由会员分享,可在线阅读,更多相关《LECROY WS Series Remote Control 电路图.pdf(2页珍藏版)》请在收音机爱好者资料库上搜索。

1、 1 WAVESURFER OSCILLOSCOPE Errata Sheet for Remote Control Manual Most of the commands contained in the Remote Control Manual for the WaveMaster DSO and other X-Stream instruments apply also to the WaveSurfer oscilloscope. There are also two new WaveSurfer scope commands that are not in the manual.

2、The Remote Control Manual can be found in the Technical Library at LeCroys Web site . Please refer to the following table for additions, exclusions, and modifications. Command Status Notes COMBINE_CHANNELS Not Applicable CURSOR_MEASURE Modified Allowed modes: CUST ,STAT, FAIL, HREL ,ABS, DELTA, SLOP

3、E, OFF, PASS, VREL ,ABS, DELTA CURSOR_SET Modified Allowed traces: F1, F5, F6, F7, F8, TA, C1, C2, C3, C4, M1, M2, M3, M4 F5 to F8 correspond to Z1 to Z4, respectively. CURSOR_VALUE? Modified Allowed traces: F1, F5, F6, F7, F8, TA, C1, C2, C3, C4 CURSORS Not Applicable DEFINE Modified Allowed functi

4、on is F1 only. Not all function parameters are allowed. FUNCTION_RESET Modified Allowed functions: F1 or TA. GRID Modified Allowed arguments: SINGLE, XYONLY, XYSINGLE HOR_MAGNIFY Modified Allowed prefixes: TA or F1 for the Math trace Z1 to Z4 for F5 to F8 F2 to F4, TB to TD are not valid HOR_POSITIO

5、N Modified Allowed prefixes: TA or F1 for the Math trace Z1 to Z4 for F5 to F8 F2 to F4, TB to TD are not valid IMPEDANCE New This command sets the input impedance. Syntax: :IMPEDANCDE := A1M, D1M, D50, GND, 0VL For external trigger: D50, D1M, GND INSP? Modified Allowed prefixes: C1 to C4 for channe

6、l traces M1 to M4 for memory traces TA or F1 for the Math trace Z1 to Z4 for F5 to F8 RadioFans.CN 收音机爱 好者资料库 WAVESURFER OSCILLOSCOPE 2 F2 to F4, TB to TD are not valid MEMORY_SIZE Not Applicable PARAMETER Modified Allowed parameter types: CUST, OFF Allowed parameter readout: STAT, OFF PARAMETER_CLR

7、 Modified Pass/Fail is not applicable. PARAMETER_CUSTOM Modified Only parameter columns 1 to 6 allowed. PARAMETER_DELETE Modified Pass/Fail is not applicable. Only parameter columns 1 to 6 allowed. PARAMETER_STATISTICS Modified Allowed parameter type: CUST Allowed parameters: P1 to P6 PARAMETER_VALU

8、E? Modified Allowed traces: F1, F5, F6, F7, F8, TA, C1, C2, C3, C4 Not allowed: CUST7, CUST8 PASS_FAIL Modified argument is not valid. settings allowed: AllTrue, AllFalse PER_CURSOR_SET Modified Allowed traces: F1, F5, F6, F7, F8, TA, C1, C2, C3, C4, M1, M2, M3, M4 PERSIST_SAT Modified Trace selecti

9、on is not allowed. PERSIST_SETUP Modified Allowed mode: ALL SAMPLE_CLOCK Modified Allowed states: INTERNAL, ECL, TTL, 0V SEQUENCE Not Applicable STORE_SETUP Modified F2 to F4, TB to TD are not valid TRACE Modified F2 to F4, TB to TD are not valid TRIG_COUPLING Modified ETM10 is not valid New values:

10、 AC, DC, HF, HFREJ, LFREJ TRIG_LEVEL Modified ETM10 is not valid TRIG_SELECT Modified New types: TV, RUNT, SLEW TRIG_SLOPE Modified ETM10 is not valid TRIG_WINDOW New The TRIG_WINDOW command sets the window amplitude in volts on the current Edge trigger source. The window is centered around the Edge trigger level. Syntax: TRIG_WINDOW := 0 to 25 V VERT_MAGNIFY Modified F2 to F4, TB to TD are not valid VERT_POSITION Modified F2 to F4, TB to TD are not valid WAVEFORM Modified F2 to F4, TB to TD are not valid RadioFans.CN 收音机爱 好者资料库

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 仪器仪表 > LeCroy

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号