《KEI 7037 Operations 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI 7037 Operations 电路图.pdf(72页珍藏版)》请在收音机爱好者资料库上搜索。
1、Instruction Manual Contains Operating and Servicing Information Model 7037 Single-Pole Relay-Digital I/O Card 7037-901-01 Rev. A / 5-97 RadioFans.CN 收音机爱 好者资料库 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 year from da
2、te of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. T
3、o exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs will be made and the prod
4、uct returned, transportation prepaid. Repaired or replaced products are warranted for the balance of the origi- nal warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modifi cation without Keithleys express written consent, or
5、misuse of any product or part. This warranty also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY
6、IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDI- RECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT O
7、F THE USE OF ITS INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PERSON, OR DAM
8、AGE TO PROPERTY. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, OH 44139 216-248-0400 Fax: 216-248-6168 CHINA:Keithley Instruments China Yuan Chen Xin Building, Room 705 12 Yumin Road, Dewai, Madian Beijing 100029 8610-62022886 Fax: 8610-62022892 FRANCE:Keithley Instruments SARL BP 60 3 All
9、e des Garays 91122 Palaiseau Cdex 33-1-60-11-51-55 Fax: 33-1-60-11-77-26 GERMANY:Keithley Instruments GmbH Landsberger Strasse 65 D-82110 Germering, Munich 49-89-8493070 Fax: 49-89-84930759 GREAT BRITAIN:Keithley Instruments, Ltd. The Minster 58 Portman Road Reading, Berkshire RG30 1EA 44-118-957566
10、6 Fax: 44-118-9596469 ITALY:Keithley Instruments SRL Viale S. Gimignano 38 20146 Milano 39-2-48303008 Fax: 39-2-48302274 NETHERLANDS:Keithley Instruments BV Avelingen West 49 4202 MS Gorinchem 31-(0)183-635333 Fax: 31-(0)183-630821 SWITZERLAND:Keithley Instruments SA Kriesbachstrasse 4 8600 Dbendorf
11、 41-1-8219444 Fax: 41-1-8203081 TAIWAN:Keithley Instruments Taiwan 1FL., 1, Min Yu First Street Hsinchu, Taiwan, R.O.C. 886-35-778462 Fax: 886-35-778455 RadioFans.CN 收音机爱 好者资料库 Model 7037 Single-Pole Relay-Digital I/O Card Instruction Manual 1997, Keithley Instruments, Inc. All rights reserved. Clev
12、eland, Ohio, U.S.A. First Printing, May 1997 Document Number: 7037-901-01 Rev. A RadioFans.CN 收音机爱 好者资料库 Manual Print History The print history shown below lists the printing dates of all Revisions and Addenda created for this manual. The Revision Level letter increases alphabetically as the manual
13、undergoes subsequent updates. Addenda, which are released between Revi- sions, contain important change information that the user should incorporate immediately into the manual. Addenda are num- bered sequentially. When a new Revision is created, all Addenda associated with the previous Revision of
14、the manual are incorporated into the new Revision of the manual. Each new Revision includes a revised copy of this print history page. Revision A (Document Number 7037-901-01). May 1997 All Keithley product names are trademarks or registered trademarks of Keithley Instruments, Inc. Other brand and p
15、roduct names are trademarks or registered trademarks of their respective holders. Safety Precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some in- struments and accessories would normally be used with non-haz- ardo
16、us voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualifi ed personnel who recog- nize shock hazards and are familiar with the safety precautions re- quired to avoid possible injury. Read the operating information carefully before using
17、the product. The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety proced
18、ures and proper use of the instru- ment. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating, for example, setting the line voltage or replac- ing consumable materials. Maintenance p
19、rocedures are described in the manual. The procedures explicitly state if the operator may per- form them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, and perform safe installations and repairs of products. Only properly trai
20、ned ser- vice personnel may perform installation and service procedures. Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fi xtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage
21、levels greater than 30V RMS, 42.4V peak, or 60VDC are present. A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring. Users of this product must be protected from electric shock at all times. The responsible body must ensure that users are prev
22、ented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Product users in these circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 volts,
23、 no conductive part of the circuit may be exposed. As described in the International Electrotechnical Commission (IEC) Standard IEC 664, digital multimeter measuring circuits (e.g., Keithley Models 175A, 199, 2000, 2001, 2002, and 2010) measuring circuits are Installation Category II. All other inst
24、ru- ments signal terminals are Installation Category I and must not be connected to mains. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance limited sources. NEVER connect switching cards directly to AC mains. When con- necting sources t
25、o switching cards, install protective devices to lim- it fault current and voltage to the card. Before operating an instrument, make sure the line cord is connect- ed to a properly grounded power receptacle. Inspect the connecting cables, test leads, and jumpers for possible wear, cracks, or breaks
26、before each use. For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jump- ers, installing or r
27、emoving switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dry, insulated
28、 surface capable of withstanding the voltage being measured. Do not exceed the maximum signal levels of the instruments and ac- cessories, as defi ned in the specifi cations and operating informa- tion, and as shown on the instrument or test fi xture panels, or switching card. When fuses are used in
29、 a product, replace with same type and rating for continued protection against fi re hazard. Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections. If you are using a test fi xture, keep the lid closed while power is ap- plied to t
30、he device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to safety earth ground using the wire recommended in the user documentation. The symbol on an instrument indicates that the user should re- fer to the operating instructions located in the man
31、ual. The symbol on an instrument shows that it can source or mea- sure 1000 volts or more, including the combined effect of normal and common mode voltages. Use standard safety precautions to avoid personal contact with these voltages. The WARNING heading in a manual explains dangers that might resu
32、lt in personal injury or death. Always read the associated infor- mation very carefully before performing the indicated procedure. The CAUTION heading in a manual explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be
33、connected to humans. Before performing any maintenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fi re, replacement components in mains circuits, including the power transformer, test leads, and input jacks, must be purchased from Keithley Instru-
34、ments. Standard fuses, with applicable national safety approvals, may be used if the rating and type are the same. Other components that are not safety related may be purchased from other suppliers as long as they are equivalent to the original component. (Note that se- lected parts should be purcha
35、sed only through Keithley Instruments to maintain accuracy and functionality of the product.) If you are unsure about the applicability of a replacement component, call a Keithley Instruments offi ce for information. To clean the instrument, use a damp cloth or mild, water based cleaner. Clean the e
36、xterior of the instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. ! Table of Contents 1General Information Introduction.1-1 Features. 1-1 Warranty information. 1-2 Manual addenda. 1-2 Safety symbols and terms . 1-2 Specifications. 1
37、-2 Unpacking and inspection. 1-2 Inspection for damage. 1-2 Handling precautions .1-2 Shipping contents. 1-2 Instruction manual. 1-3 Repacking for shipment. 1-3 Optional accessories. 1-3 2Relay Switch Configuration Introduction. 2-1 Basic switch configuration (SPST). 2-1 3Digital I/O Configuration Introduction. 3-1 Digital outputs. 3-1 Controlling pull-up devices. 3-1 Controlling devices using pull-up resistors. 3-2 Digital inputs. 3-2 i 4Card Connections and Installation Introduction . 4-1 Handling precautions. 4-2 Digital I/O connections. 4-2 Voltage source jumper. 4-2 Pull-up resistors.