MARCONI 6970 SUMMARY CARD 电路图.pdf

上传人:cc518 文档编号:203310 上传时间:2025-03-08 格式:PDF 页数:4 大小:748.28KB
下载 相关 举报
MARCONI 6970 SUMMARY CARD 电路图.pdf_第1页
第1页 / 共4页
MARCONI 6970 SUMMARY CARD 电路图.pdf_第2页
第2页 / 共4页
MARCONI 6970 SUMMARY CARD 电路图.pdf_第3页
第3页 / 共4页
亲,该文档总共4页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《MARCONI 6970 SUMMARY CARD 电路图.pdf》由会员分享,可在线阅读,更多相关《MARCONI 6970 SUMMARY CARD 电路图.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。

1、For the very latest specifications T Th he e w wo or rl ld d s s mmo os st t p po or rt ta ab bl le e R RF F a an nd d MMi ic cr ro ow wa av ve e P Po ow we er r MMe et te er r, , d de es si ig gn ne ed d f fo or r a ac cc cu ur ra at te e p po ow we er r mme ea as su ur re emme en nt ts s i in n t

2、th he e f fi ie el ld d Power Meters 6970 RF Power Meter Hand-held for portability Battery powered for field use Wide frequency range: 30 kHz to 46 GHz Analog bargraph Excellent accuracy traceable to National Standards Power levels from -70 dBm (100 pW) to +44 dBm (25 W) Internal power reference Aud

3、ible Pass/Fail limits alarm Rugged case Four digit display The 6970 RF Power Meter provides precision microwave power measurements in a hand portable battery-powered package. A wide range of user features, including duty cycle, rel- ative power measurements and limit checking make the 6970 Power Met

4、er highly versatile. The same wide range of power sensors used with the IFR 6960 PowerMeters and the 6200B series Microwave Test Set are used by the 6970. Field and Bench Use The 6970 is designed for both field and bench use. For the installa- tion and maintenance engineer the instrument replaces la

5、rge and expensive meters with no loss of measurement performance. Rechargeable batteries mean that there is no need for an AC supply; this greatly eases measurements at remote sites such as an antenna tower. Additional benefits of the 6970 are lower cost and portability. An optional soft carrying po

6、uch with both belt loop and shoulder strap enable the 6970 to be easily carried in field environments For bench operation the instrument takes up little bench space and it can be powered from the AC adapter. Battery operation is ideal for field operation High Accuracy The 6900 series power sensors a

7、ll have an excellent return loss spec- ification to minimise mismatch errors in power measurements. Correction for power sensor frequency response and high power non-linearity is also provided by entry of calibration factor and lin- earity factor values into the 6970. issue 7.qxd 03/12/04 10:58 Page

8、 1 RadioFans.CN 收音机爱 好者资料库 All the power sensors are individually calibrated and supplied with a calibration data chart. The auto ZERO function reduces offset errors on each of the 6970 ranges. This increases measurement accuracy at low power levels and improves the measurement sensitivity. Built-In

9、 Power Reference The built-in power reference provides an accurate 0 dBm (1 mW) 50 MHz calibration signal. Power sensors can be calibrated against this reference for improved measurement accuracy and traceability. The power reference is automatically switched on during a CAL pro- cedure or it can be

10、 enabled at any time to provide a traceable 0 dBm signal for verification. Operation The instrument front panel consists of a keyboard and a four digit LCD with annunciators. Power levels are clearly displayed on a digi- tal readout with an analog bargraph to facilitate peaking and nulling. Power le

11、vels may either be displayed in logarithmic units such as dBm or dBV or in Watts. To save battery life, the unit powers down six minutes after the last key press. 6970 will operate for 7 hours from a full battery charge. When the instrument powers down the last operator set-up is stored and this wil

12、l be the state the 6970 assumes when it is next switched on. Upper and lower power limits can be set. An audio and visual alarm alerts the user of a measurement that is out of limits. This is useful to set a power to a pre-determined level as well as for monitor-ing purposes. The 6970 is fully auto-

13、ranging but manual range hold is also possible. Manual range selection is used when measuring modulated or unsta- ble signals. The display indicates either AUTO or MAN as appropri- ate and will also provide information of over/under-range conditions. Wide Range of Power Sensors The 6970 uses the sam

14、e rugged IFR power sensors that have been developed for the 6960 Power Meter and 6200B series Microwave Test Set. A wide range of 17 sensors is available covering the frequencies from 30 kHz to 46 GHz. Power level measured depends on sensor type, sensors cover from -70 dBm (0.1 nW) to +44 dBm (25 W)

15、. To cater for the different frequency ranges connector types include N type, PC 3.5 mm, 2.92 mm and N type (75 W). S SP PE EC CI IF FI IC CA AT TI IO ON N Frequency Range 30 kHz to 46 GHz Depending on sensor used Power Range -70 dBm (0.1 nW) to +44 dBm (25 W) Depending on sensor used Power Sensors

16、Supported 6910 series (-30 dBm to +20 dBm) 6920 series (-70 dBm to -20 dBm) 6930 series (-15 dBm to +35 dBm) 6930 series opt 2 (-5 dBm to +44 dBm) Instrumentation Accuracy Including Carryover 1%range 0, 1, 2 5%range 3 Power Accuracy After calibration using 0 dBm, 50 MHz power reference: 0.2 dB Measu

17、ring a 50 MHz signal in the centre of the power sensor dynamic range, from a source with a return loss better than 14 dB DISPLAY Resolution 4 digits for positive readings 3 digits for negative readings Units dBm, nW, mW, mW, W, mV, V, dBV Annunciators Analog bargraph, Battery low indicator, Indicati

18、on of auto-ranging or manual range, Upper and lower limits CORRECTION Linearity Factor Ability to enter in range 0.01 to 15 with 0.01 resolution Defaults to standard setting Calibration Factor Ability to enter in range 0.01% to 200% Resolution:0.01 to 99.99% 0.1 100% and above Auto-Calibration Abili

19、ty to calibrate against a 0 dBm (1 mW), 50 MHz power reference Auto-Zero Removes DC offset from gain stages and power sensor Set 400 nW (6910 series) 100 pW (6920) 200 pW (6923/6924) 7 hours from full charge when new Operating Time 7 hours from full charge when new Time to Recharge 14 hour Power Con

20、sumption 250 mW DC Input Requirement 9 V to 21 V, 120 mA via a 2.1 mm power connector GENERAL Operating Temperature Range 0 to +55C Storage Temperature Range -40 to +55C Storage Humidity Range Up to 85% RH at +40C Storage Altitude Range Up to 4600 m (15000 ft) DIMENSIONS AND WEIGHT HeightWidthDepthW

21、eight 50 mm88 mm190 mm550 g 1.9 in3.5 in7.5 in ELECTROMAGNETIC COMPATIBILITY Conforms with the protection requirements of the EEC Council Directive 89/336/EEC. Conforms with the limits specified in the following stan- dards: IEC/EN61326-1 : 1997, RF Emission Class B, Immunity Table 1, Performance Cr

22、iteria B SAFETY Conforms with the requirements of EEC Council Directive 73/23/EEC (as amended) and the product safety standard IEC / EN 61010-1 : 2001 + C1 : 2002 + C2 : 2003 for class 3 portable equipment, for use in a Pollution Degree 2 environment. The instrument is designed to be operated from a

23、n Installation Category 1 supply. POWER REFERENCE Frequency 50 MHz 0.05 MHz Power level 0 dBm (1 mW) Uncertainty 0.7% traceable to National Standards Accuracy 1.2% worst case for one year Output Connector N (female), 50. Adapters are supplied with 75 , 3.5 mm and 2.92 mm power sensors. issue 7.qxd 0

24、3/12/04 10:58 Page 3 RadioFans.CN 收音机爱 好者资料库 V VE ER RS SI IO ON NS S A AN ND D A AC CC CE ES SS SO OR RI IE ES S When ordering please quote the full ordering number information. Ordering Numbers Versions 6970RF Power Meter with built-in power reference 6970 RF Power Meter must be used with one of t

25、he AC Adapters listed below. One Adapter must therefore be ordered with each instrument 54441/016AC Adapter - UK Style 54441/017AC Adapter - European Style 54441/018AC Adapter - USA Style Supplied with 43138/6631.5 m Power Sensor Cable 46882/182Operating Manual 46882/183Summary Card 23421/6412.1 mm

26、Power Connector Plug Accessories 54112/159Carrying Pouch 54311/171DC Supply Lead 46882/207Service Manual 54417/002Waveguide 22 to 2.92 mm Transformer POWER SENSORS - STANDARD 56910/90010 MHz to 20 GHz (-30 dBm to +20 dBm) Type N. 56911/90010 MHz to 20 GHz (-30 dBm to +20 dBm) APC 7. 56912/90030 kHz

27、to 4.2 GHz (-30 dBm to +20 dBm) Type N. 56913/90010 MHz to 26.5 GHz (-30 dBm to +20 dBm) MPC 3.5. 56914/00110 MHz to 40 GHz (-30 dBm to +20 dBm) 2.92 mm. 56914/00210 MHz to 40 GHz (-30 dBm to +20 dBm) 2.92 mm plus waveguide 22 coax transition and calibration table. 56914/00310 MHz to 46 GHz (-30 dBm

28、 to +20 dBm) 2.92 mm. 56919/90075 30 kHz to 3 GHz (-30 dBm to +20 dBm) Type N POWER SENSORS - LOW POWER 56920/90010 MHz to 20 GHz (-70 dBm to -20 dBm) Type N. 56923/90010 MHz to 26.5 GHz (-65 dBm to -20 dBm) MPC 3.5 56924/00110 MHz to 40 GHz (-65 dBm to -20 dBm) 2.92 mm. 56924/00210 MHz to 40 GHz (-

29、65 dBm to -20 dBm) 2.92 mm plus waveguide 22 coax transition and calibration table 56924/00310 MHz to 46 GHz. (-65 dBm to -20 dBm) 2.92 mm. Power Sensors - High power 56930/90010 MHz to 18 GHz (-15 dBm to +35 dBm) Type N. 56932/90030 kHz to 4.2 GHz (-15 dBm to +35 dBm) Type N. 56934/00110 MHz to 40

30、GHz (-15 dBm to +30 dBm) 2.92 mm 56934/00210 MHz to 40 GHz (-15 dBm to +30 dBm) 2.92 mm plus waveguide 22 coax transition and calibration table 56934/00310 MHz to 46 GHz (-15 dBm to +30 dBm) 2.92 mm 56930/00210 MHz to 18 GHz (-5 dBm to +44 dBm) Type N 56932/00230 kHz to 4.2 GHz (-5 dBm to +44 dBm) T

31、ype N Part No. 46891/066, Issue 7, 02/04 CHINA Tel: +86 (21) 6282 8001 Fax: +86 (21) 6282 8002 EUROPE Tel: +44 (0) 1438 742200 Fax: +44 (0) 1438 727601 FRANCE Tel: +33 1 60 79 96 00 Fax: +33 1 60 77 69 22 HONG KONG Tel: +852 2832 7988 Fax: +852 2834 5364 SCANDINAVIA Tel: +45 9614 0045 Fax: +45 9614

32、0047 SPAIN Tel: +34 (91) 640 11 34 Fax: +34 (91) 640 06 40 UNITED KINGDOM Tel: +44 (0) 1438 742200 Toll Free: +44 (0800) 282 388 (UK only) Fax: +44 (0) 1438 727601 USA Tel: +1 (316) 522 4981 Toll Free: +1 (800) 835 2352 (US only) Fax: +1 (316) 522 1360 w w w . a e r o f l e x . c o m i n f o - t e s

33、 t a e r o f l e x . c o m As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any con- tract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent company Aeroflex, Inc. Aeroflex 2003. issue 7.qxd 03/12/04 10:58 Page 4