《5021_Test_Spec 电路图.pdf》由会员分享,可在线阅读,更多相关《5021_Test_Spec 电路图.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、c - cC - c :- wi: . - . TEST SPECIFICATION: TL Audio IVORY 5021 COMPRESSOR Ref. Number: TS5021 Issue 1. Page 1 of 4 Tolerance on inputs +/- 0.3 dBu, outputs +/- 1 dBu, unless othem;se stated. Tests must be perfonned in sequence, with controls changed as indicated. 1. HISTORY SHEET. Each unit must be
2、 accompanied by an INSTRUMENT HISTORY SHEET. Ensure the History Sheet has been completed satisfactorily. 2. MAINS VOLTAGE. Check the Mains Switch setting on the rear panel. It must be 230V. 3. EARTH CONTINUITY. Check the earth connection from the IEC connector to the rear panel. Check the tightness
3、of the Rear Panel Earth connection. It must be tight. Check that an Earth Symbol has been placed adjacent to the Earth Terminal. 4. VISUAL INSPECTION. Inspect the unit, paying particular attention to the following: 4.1 PSU Capacitors and Diodes. Value and orientation. 4.2 Intergrated circuits. Type
4、and orientation. 4.3 Transformer Wiring. . Wired as per PCB silk screen. Check insulation of wires. 4.4 Soldered Joints. Check for solder shorts, dry or unsolderedjoints. 4.5 Internal Fuses. Check fuses are seated correctly. Check values as Stated on the PCB Silk Screen. 4.6 External Finish. Check f
5、ront and rear panel silk screening for legilbility. Check all external surfaces for marks and blemishes. Check that all screw heads are undamaged, check screws are tight. 4.7 Knobs and Switches. Check that Knobs and Switches move freely. Check they are correctly aligned with their legends. Check the
6、y are uniformly spaced from the front panel. 4.8 .,.ED Alignment. Check that all LEDs are equally spaced from the front panel. . 5. FIT VALVES Check the valve bases for splayed pins. Perform corrective action as necessary. All valves are ECC83/l2AX7 A unless otherwise Stated. - Plug valve in each so
7、cket, ensure valve isa tight fit. Do not wiggle valve in socket 6. SWITCH ON. Check Mains Switch moves freely. Leave in OFF position. Set DVM to DC Voltage and connect between Ground & + 15 volt point on PCB. Connect the IEC Mains Cord to the Mains Inlet. Switch unit On. Check each supply in turn as
8、 quickly as possible. Switch OFF if a supply is not present. 6.1 + 15 volt rail. + 15.00 volts +/- 0.25v. 6.2 -15 volt rail. -15.00 volts +/- 0.25v. 6.3 lIT voltage 150 volts +/- 8.Ov. 6.4 Heater voltages +6.3 volts & -6.3 volts +/- 1.Ov. 7. LED CHECK. Using the appropriate controls check all LEDs i
9、lluminate together. The DRIVE and PEAK LEDs may be excluded from this test. From Serial Number: 58()()01 To Serial Number: RadioFans.CN 收音机爱 好者资料库 -.- . TEST SPECIFICATION: TL Audio IVORY 5021 COMPRESSOR Ref. Number: TS5021 Issue 1. Page 2 of 4 Toleral!ce 011 inputs +1- 0.3 dBu, outputs +1- 1 dBu, u
10、nless otherwise stated. Tests must be perfOffi!ed in sequet!.:e, wid! controls cl!anged as indicated. 8. INITIAL SETTINGS. Set all Front and Rear panel switches to the OUT position. Set all Centre Detent pots to mid-position. Set all other Pots fully anti-clockwise. Set all Rotary Switches fully ant
11、i-clockwise. 9. TEST EQUIPMENT. To perform the tests to this procedure use: A calibrated Signal Generator.(Sinewave) 0.0 dBu 1 kHz unless stated. A calibrated Signal Analyser.(dBumID+N%) With 22-22k Filter set to On. An Oscilloscope. A Digital Voltmeter. 9.1 REFERENCES All unit settings are on the F
12、ront Panel unless stated otherwise. . All Settings(RVnn) and Test Points(TPnn) are on the Main PCB unless stated otherwise. 9.2 mSTORY SHEET. All faults/rework must be logged on the History Sheet. Where pratical show the operator/assembler the nature of the problem. Serious/Repetitive faults must be
13、 reported to the Production Manager. After the unit has been succesfully tested Sign & Date the History Sheet. The History Sheet must remain with the unit at all times. After the unit is dispatched the History Sheet must be filed for analysis. .: : Re.ision Histo From Serial Number: 580001 To Serial
14、 Number: RadioFans.CN 收音机爱 好者资料库 - ,- TEST SPECIFICATION: TL Audio IVORY 5021 COMPRESSOR Ref. Number: TS5021 Issue 1, Page 3 of 4 Tolerance on inputs +/- 0.3 dBu, outputs +/- 1 dBu, unless ot1le1ise stated. Tests must be perromled ill sequence, with controls chwIged as indicated. 10. INITIAL TESTS.
15、10.1 SIGNAL BALANCE. Connect input to Channel 2 XLR. 0.0 dBu. Alternately scope pins 2 & 3 of Channel 2 OUTPUT XLR while adjusting R V2. Adjustment is complete when the signals at pins 2 & 3 are equal. Repeat Test with input to Channell XLR using RVI. Conduct the Tests on Channell and then repeat al
16、l the Tests on Channel 2. Where applicable Channel 2 test references are shown in brackets. 10.2 COMPRESSOR OFFSET. Connect DVM to Test Point on LHS(RHS) Front Panel PCB. . Adjust RV28(RV27) for a reading of -400 mVolts DC. 10.3 GATE LEVEL. Remove input signal. Connect DVM to TP2(IPl). Adjust RV9(RV
17、6) for a reading of +80 mVolts DC Note: Value will fluctuate slightly. If +80 mVolts cannot be achieved shunt a 10 Meg resistor across R93(R48) 11.0 CALffiRATION. Signal In = 0.0 dBu to LINE XLR. Signal Out from Output XLR. Set Analyser Filter to ON. 11.1 LINE INPUT GAIN. SetRV8(RVI0)forO.OdBu. ,. I
18、NPUf GAIN pot variation = +/- 20 dBu. . : 11.2 COMPRESSOR GAIN. Select COMP IN. Set RVll(RV7) for 0.0 dBu. 11.3 HUM & NOISE. MUTE the Output of the Signal Generator. The output value should read -80 dBu or better. 11.4 INSTRUMENT INPUT. Signal In = -20 dBu to Front Panel Jack Socket.(Single Pole) Se
19、t INPUT GAIN to mid-position. Check for -7.0 dBu +/- 1.0 dBu. 11.5 UNBAL IN/OUT. Signal In = -20 dButo Rear Panel Unbal Input.(Singie Pole) Signal Out from Rear Panel Unbal Output.(Double Pole) Set INPUT Switch to LINE position. Check for -20 dBu +/- 1.0 dBu. 11.6 DISTORTION Set Signal Into 1kHz. Se
20、t Analyser to read THD+N(%). Check for a value better than 0.2%. Set Signal In to 100 Hz. Set THRESHOLD & RATIO controls Clockwise. Check for a value better than 2.0%. Set THRESHOLD & RATIO controls Anti-clockwise. Return Analyser to read dBu. Reision Histo From Serial Number: 580001 To Serial Numbe
21、r: RadioFans.CN 收音机爱 好者资料库 - . TEST SPECIFICATION: TL Audio IVORY 5021 COMPRESSOR Ref. Number: TS5021 Issue 1. Page 4 of 4 Tolerallce 011 inputs +/- 0.3 dBu, outputs +/- 1 dBu, unless otherwise Tests must be perfonned itl sequellce, witll controls changed as itIdicated. 11.7 NOMINAL GAIN. Set Rear P
22、anel INPUT GAIN switch to IN. Check for a reading of -14 dBu. Set Rear Panel INPUT GAIN switch to OUT. Set Rear Panel OUTPUT GAIN switch to IN. Check for a reading of + 14 dBu. Set Rear Panel OUTPUT GAIN switch to OUT. 11.8 DRIVE / PEAK LEDs. Set Signal In to +2.0 dBu. Check that DRIVE LED is Off. S
23、et Signal In to +6.0 dBu. Check that DRIVE LED is just ON. Set Signal In to + 16 dBu. Check that DRIVE LED is fully ON. Set Signal In to +25 dBu. Check that PEAK LED is ON. Set Signal In to +15 dBu. Check that PEAK LED is OFF. Increase OUTPUT GAIN control PEAK LED comes ON. . The reading should be +
24、20 dBu +/- 1.0 dBu. Set Signal In to 0.0 dBu. Vary OUTPUT GAIN control so the reading is 0.0 dBu. 11.9 COMPRESSOR THRESHOLD. Set ATTACK and RELEASE switches clockwise. Signal In = +4.0 dBu. Set THRESHOLD & RATIO controls clockwise. Set RV3O(RV29) on LHS(RHS) Front Panel PCB for -9.0 dBu. 11.10 METER
25、 CALffiRATION. Set THRESHOLD control anti-clockwise. ,. Set RV5(RVI4) for Zero dBu on Meter. Set GAIN REDUCTION to ON. : Settings are interactive. Set RV4(RVI3) for Zero dBu on Meter. Set THRESHOLD control clockwise. Set RATIO until reading is -2.0 dBu. Set RV3(RVI2) for -6 dBu on Meter. Set THRESHO
26、LD control anti-clockwise and check Meter reads Zero Repeat settings until correct readings are achieved. 11.11 GAIN MAKE-UP. Set THRESHOLD anti-clockwise and GMU clockwise. Check reading is 24.0 dBu +/- 2.0 dBu. Set all Compressor pots fully anti-clockwise. Set COMP IN to Off. 12.0 GATE TEST. Set t
27、he GATE/EXPANDER control to the -40 dBu position. Set Signal In to -40 dBu. Check GATE LED is OFF. Check for a reading of -40 dBu +/- 2.0 dBu. Set Signal In to -44 dBu. Check GATE LED is ON. Check for a reading less than -80 dBu. Set Signal In to -20 dBu. Check GAlE LED is OFF. Set tIle G_A.TE/EXPAN
28、DER control clockwise until the GATE LED comes ON. Check the control position is -20 dBu +/- 5.0 dBu. Remove Input XLR lead from LINE XLR Set the GATE/EXPANDER control to OFF. Check GAlE LED is OFF. Set the G.A.TE /EXPANDER control clockwise until the GATE LED comes ON. Check the control position is between OFF and -40 dBu. Revision History From Serial Nunlber: 580001 To Serial Number: