1、 DCS-E 1kW Series all circuits and/or terminals to be touched must be safety grounded to the chassis. After the unit has been operating for some time, the metal near the rear of the unit may be hot enough to cause injury. Let the unit cool before handling. Qualified service personnel need to be awar
2、e that some heat sinks are not at ground, but at high potential. These operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be followed. Neither Sorensen, San Diego, California
3、, USA, nor any of the subsidiary sales organizations can accept any responsibility for personal, material or consequential injury, loss or damage that results from improper use of the equipment and accessories. i RadioFans.CN 收音机爱 好者资料库 SAFETY SYMBOLS ii SORENSEN FIVEYEAR WARRANTY Sorensen, a divisi
4、on of Elgar Electronics Corporation, warrants its products to be free from defects in material and workmanship. This warranty is effective for five years from the date of shipment of the product to the original purchaser. Liability of Sorensen under this warranty shall exist provided that: the Buyer
5、 exposes the product to normal use and service and provides normal maintenance on the product; Sorensen is promptly notified of defects by the Buyer and that notification occurs within the warranty period; the Buyer receives a Return Material Authorization (RMA) number from Sorensens Repair Departme
6、nt prior to the return of the product to Sorensen for repair, phone 800-458-4258; the Buyer returns the defective product in the original, or equivalent, shipping container; if, upon examination of such product by Sorensen it is disclosed that, in fact, a defect in materials and/or workmanship does
7、exist, that the defect in the product was not caused by improper conditions, misuse, or negligence; and, that Sorensen QA seal and nameplates have not been altered or removed and the equipment has not been repaired or modified by anyone other than Sorensen authorized personnel. This warranty is excl
8、usive and in lieu of all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness of the product to a particular purpose. Sorensen, its agents, or representatives shall in no circumstance be liable for any direct, indirect, special, pen
9、al, or consequential loss or damage of any nature resulting from the malfunction of the product. Remedies under this warranty are expressly limited to repair or replacement of the product. CONDITIONS OF WARRANTY To return a defective product, contact a Sorensen representative or the Sorensen factory
10、 for an RMA number. Unauthorized returns will not be accepted and will be returned at the shippers expense. For Sorensen products found to be defective within thirty days of receipt by the original purchaser, Sorensen will absorb all ground freight charges for the repair. Products found defective wi
11、thin the warranty period, but beyond the initial thirty-day period, should be returned prepaid to Sorensen for repair. Sorensen will repair the unit and return it by ground freight pre-paid. Normal warranty service is performed at Sorensen during the weekday hours of 7:30 am to 4:30 pm Pacific time.
12、 Warranty repair work requested to be accomplished outside of normal working hours will be subject to Sorensen non-warranty service rates. Warranty field service is available on an emergency basis. Travel expenses (travel time, per diem expense, and related air fare) are the responsibility of the Bu
13、yer. A Buyer purchase order is required by Sorensen prior to scheduling. A returned product found, upon inspection by Sorensen, to be in specification is subject to an inspection fee and applicable freight charges. Equipment purchased in the United States carries only a United States warranty for wh
14、ich repair must be accomplished at the Sorensen factory. Committed to Quality.Striving for Excellence iii This page intentionally left blank. iv CONTENTS SECTION 1 FEATURES AND SPECIFICATIONS .1-1 1.1 Description.1-1 1.2 Operating Modes.1-1 1.3 Power Supply Features .1-1 1.4 Specifications.1-3 1.4.1
15、 Electrical Specifications for 1kW Models.1-3 1.4.2 Electrical Specifications for 1.2kW Models.1-4 1.4.3 Physical Specifications.1-5 1.4.4 Mechanical Specifications .1-6 SECTION 2 INSTALLATION AND OPERATION.2-1 2.1 General.2-1 2.2 Initial Inspection.2-1 2.3 Installation.2-1 2.3.1 Input Voltage Selec
16、tion.2-1 2.3.2 Input Line Impedance.2-2 2.3.3 Ventilation Requirements.2-2 2.3.4 Output Voltage Biasing.2-2 2.3.5 Rack Mounting.2-2 2.4 Controls, Connectors, and Indicators .2-4 2.4.1 Front Panel.2-4 2.4.2 Rear Panel.2-4 2.4.3 J3 Program, Sense and Monitor Connector Description .2-5 Operation Manual
17、 v Contents Sorensen DCS Series 1kW and 1.2kW Supplies 2.5 Initial Functional Tests .2-6 2.6 Standard Operation.2-7 2.6.1 Load Conductor Ratings .2-7 2.6.2 Load Connection and Grounding.2-7 2.6.3 Inductive Loads.2-8 2.6.4 Remote Sensing.2-8 2.6.5 Negative Output Operation .2-9 2.7 Single Supply Oper
18、ation (Local Mode) .2-9 2.8 Multiple Supplies.2-10 2.8.1 Series Operation.2-10 2.8.2 Parallel Operation .2-10 2.8.3 Split Supply Operation .2-11 2.9 Over Voltage Protection (OVP).2-11 2.9.1 Front Panel OVP Operation .2-11 2.9.2 Remote Programming of OVP With External Voltage Sources.2-12 2.9.3 Remot
19、e Programming of OVP with an External Resistance.2-13 2.9.4 Remote Programming of OVP with External Current Sources.2-14 2.9.5 Remote OVP Sensing.2-15 2.10 Remote ON/OFF.2-15 2.10.1 Remote ON/OFF by Contact Closure.2-16 2.11 Remote Programming of Output Voltage and Current Limit .2-16 2.11.1 Program
20、ming With External Voltage Sources.2-17 2.11.2 Programming With an External Resistance .2-18 2.11.3 Programming With an External Current Source.2-19 2.12 Remote Monitoring and Status Indicators.2-21 SECTION 3 THEORY OF OPERATION 3.1 Power Circuit (A2 Assembly) .3-1 3.1.1 Basic Off-Line Switching Reg
21、ulator Theory .3-1 3.1.2 Simplified Full Bridge Converter Theory .3-3 3.1.3 Detailed Circuit Description.3-3 3.2 Meter Circuit (A1 Assembly) .3-9 3.2.1 Voltmeter.3-10 3.2.2 Current Meter.3-10 vi Operation Manual Sorensen DCS Series 1kW and 1.2kW Supplies Contents SECTION 4 MAINTENANCE, TROUBLESHOOTI
22、NG, AND CALIBRATION 4.1 General.4-1 4.2 Periodic Service.4-1 4.3 Troubleshooting.4-1 4.3.1 Preliminary Checks.4-2 4.3.2 Troubleshooting at the Operation Level.4-2 4.4 Calibration.4-3 SECTION 5 PARTS LISTS 5.1 General.5-1 5.2 Parts Ordering .5-1 5.3 Parts Lists.5-2 SECTION 6 DRAWINGS AND SCHEMATICS O
23、peration Manual vii Contents Sorensen DCS Series 1kW and 1.2kW Supplies LIST OF FIGURES Figure 2-1 DCS Series Power Supply. 2-3 Figure 3-1 Simplified Full Bridge Converter. 3-2 Figure 4-1 Trimpot Locations. 4-4 LIST OF TABLES Table 21 Wire Size and Length. 2-7 Table 41 Troubleshooting Guide. 4-2 Tab
24、le 51 DCS 1kW and 1.2kW Fuse Ratings. 5-2 Table 52 DCS 1kW Parts Lists by Model Number. 5-2 Table 53 DCS 1kW Parts Lists . 5-3 Table 54 DCS 1.2kW Parts Lists by Model Number. 5-4 Table 55 DCS 1.2kW Parts Lists . 5-5 viii Operation Manual SECTION 1 1.1 Description 1.2 1.3 FEATURES AND SPECIFICATIONS
25、DCS Series power supplies are 1000W and 1200W supplies designed to provide highly stable, continuously variable output voltage and current for a broad range of development, system, and burn-in applications. The DCS Series employs high frequency switching regulator technology to achieve high power de
26、nsity and small package size. The series consists of twelve 1000W models and twelve 1200W models. The model numbers are designated by the DCS prefix, followed by the output voltage and current ratings. For example, the model number DCS 60-18E indicates that the unit is rated at 0-60 Vdc and 0-18 Amp
27、s while a model DCS 20-50E is rated at 0-20 Vdc and 0-50 Amps. Operating Modes The DCS Series supply has two basic operating modes: Constant Voltage and Constant Current. In constant voltage mode the output voltage is regulated at the selected value while the output current varies with the load requ
28、irements. In constant current mode the output current is regulated at the selected value while output the voltage varies with the load requirements. An automatic crossover system enables the unit to switch operating modes in response to varying load requirements. If, for example, the unit is operati
29、ng in voltage mode and the load current attempts to increase above the setting of the current control, the unit will switch automatically from voltage mode to current mode. If the load current is subsequently reduced below the setting of the current control the unit will return to voltage mode autom
30、atically. Power Supply Features Twelve 1kW models with voltage ranges from 0-8 Vdc to 0-600 Vdc and current outputs from 1.7A to 125A. Twelve 1.2kW models with voltage ranges from 0-8 Vdc to 0-600 Vdc and current outputs from 2A to 140A. 115/230 Vac selectable input voltage, 50-60 Hz single phase, I
31、nstallation Category II. For Indoor Use. Simultaneous digital display of both voltage and current. Operation Manual 1-1 Features and Specifications Sorensen DCS Series 1kW and 1.2kW Supplies Automatic mode crossover into current or voltage mode. Ten turn potentiometer voltage and current controls pe
32、rmit high resolution setting of the output voltage and current from zero to the rated output. Flexible output configuration: multiple units can be connected in parallel or series to provide increased current or voltage. High frequency switching technology allows high power density, providing increased power output in a small, light package. Remote sensing to compensate for losses in power leads. Adjustable Over-Voltage Protection (OVP) External TTL, AC or