《SORENSEN DCR-B Series 1800-Watt Instruction Rev C 电路图.pdf》由会员分享,可在线阅读,更多相关《SORENSEN DCR-B Series 1800-Watt Instruction Rev C 电路图.pdf(67页珍藏版)》请在收音机爱好者资料库上搜索。
1、INSTRUCTION MANUAL FOR DCR-B SERIES 1800-WATT POWER SUPPLIES MANUAL COVERS DCR-B MODELS: 1 O-l 208 80-208 20-808 150-128 40-408 300-68 60- 308 600-38 Sorensen Company 0 676 Island Pond Road, Manchester, N.H. 03103 0 Tel 603-668-4500 0 TWX 710-220-i 339 Document Number 165041 Rev C (l/85) -,- 11-. -.
2、,-.- . - ._- “- -. ._ RadioFans.CN 收音机爱 好者资料库 C FIVE-YEAR WARRANTY Sorensen Company warrants ail parts of equipment of its manufacture, except special purpose tubes and semi- conductor devices which carry their own manufacturers warranty, to be free from defects caused by faulty material or poor wor
3、kmanship. Sorensen Company warrants its products to conform to applicable commercial or military specifications when confirmedon the Order Acknowledgment form to be free from defects caused by faulty material or poor workmanship. Sorensen Companys obligation is limited under the warranty to repair o
4、r replacement of products in kind, or at its option to issuance of a credit of original purchase price.Returns must be accompanied by a Sorensen Company Return Material Authorization lorm and conform to standard conditions for adjustment. The aforesaid warranty shall expire five (5) years lollowing
5、the last day of the month of shipment from Sorensen Companys plant. The foregoing states the entire warranty extended by Sorensen Company. No other warranty, expressed or implied, is made and, specifically, Sorensen Company makes no warranty of merchantability or fitness for any purpose. in no case
6、shall Sorensen Company be liable for any special or consequential damages. Authorization must be obtained prior to return 01 defective items. SORENSEN COMPANY RadioFans.CN 收音机爱 好者资料库 TABLE OF CONTENTS SECTION 1 1.1 1.2 1.3 1.4 SECTION 2 2.1 2.2 2.3 2.4 2.5 SECTION 3 3.1 3.2 INTRODUCTION INTRODUCTION
7、 . DESCRIPTION . 1.2.1 General . 1.2.2 Automatic Crossover . 1.2.3 Remote Sensing . 1.2.4 Series Operation . 1.2.5 Parallel Operation . 1.2.6 Remote Programming . 1.2.7 Unit Shutdown Circuit . 1.2.8 Protection Features . OPTIONAL MODIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8、. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSTALLATION GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INITIAL INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
9、LECTRICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . MECHANICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRICAL CHECK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5.1 Voltage Mode . 2.5.2 Current Mode . OPERATION GE
10、NERAL . VOLTAGE MODE OPERATION . 3.2.1 Local Sensing . 3.2.2 Remote Sensing . 3.2.3 Resistance Programming . 3.2.4 Signal Programming . Page l-l l-l l-l l-l l-2 l-2 l-2 1-2 1-2 l-2 l-3 l-3 2-l 2-l 2-l 2-l 2-2 2-2 2-2 3-l 3-4 3-4 3-4 3-6 3-8 i RadioFans.CN 收音机爱 好者资料库 SECTION 3 3.3 3.4 3.5 3.6 3.7 SEC
11、TION 4 4.1 4.2 4.3 4.4 TABLE OF CONTENTS (Contd) OPERATION CURRENT MODE OPERATION . 3.3.1 Resistance Programming . 3.3.2 Signal Programming . 3,3.3 Alternate Current Programming Method . PARALLEL OPERATION . 3.4.1 Direct Paralleling . 3.4.2 Master/ Slave Paralleling . SERIES OPERATION . 3.5.1 Direct
12、 Series connections . 3.5.2 Master/ Slave Connections . UNIT SHUTDOWN CIRCUIT . OVP . 3.7.1 OVP Adjustment . THEORY OF OPERATION INTRODUCTION . PHASE CONTROL PRINCIPLE . BLOCK DIAGRAM ANALYSIS . DETAILED CIRCUIT DESCRIPTION . 4.4.1 Reference and Bias Supplies . 4.4.2 Voltage Mode Section . 4.4.3 Cur
13、rent Mode Section . 4.4.4 Ramp Generator, Reset Circuit and Comparator 4.4.5 Blocking Oscillator Q2 . 4.4.6 Turn-On and Shut-Down Circuits . 4.4.7 Power Section . 4.4.8 Overvoltage Protector . 4.4.9 Indicator Lamps . ii Page 3-8 3-9 3-10 3-10 3-12 3-12 3-13 3-14 3-14 3-16 3-18 3-18 3-18 4-l 4-l 4-3
14、4-3 4-3 4-4 4-5 4-5 4-6 4-6 4-6 4-7 4-7 SECTION 5 5.1 5.2 5.3 5.4 5.5 5.6 SECTION 6 6.1 6.2 TABLE OF CONTENTS (Contd) MAINTENANCE Pane GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PERIODIC SERVICING . TROUBLESHOOTING . CALIBRATION . 5.4.1 Curren
15、t Mode Section, Limit Settings . PERFORMANCE TESTING . 5.5.1 Voltage Mode Regulation and Ripple. . 5.5.2 Current Mode Regulation . 5.5.3 Transient Response . HI-POT TEST PROCEDURE . 5-1 5-l 5-l 5-l 5-2 5-3 5-3 5-4 5-4 5-5 DRAWINGS AND PARTS LISTS GENERAL . . . . . . . . . . . . . . . . . . . . . . .
16、 . . . . . . . . . . . . . . . . . . . . . . . . 6-l PARTS LIST COLUMN HEADINGS DEFINED. . . . . . . . . . . . . 6-l . . . ill LIST OF ILLUSTRATIONS Figure Title Page 3-l DCR-B Controls and Indicators . 3-2 3-2 Control PCB Barrier Strip Connections . 3-3 3-3 Remote Sensing Connections . 3-5 3-4 Illu
17、stration of Load Lead Resistance (Remote Sensing). . 3-6 3-5 Voltage Mode Programming Connections . 3-7 3-6 Current Mode Programming Connections . 3-9 3-7 DCR-B Interconnections (Current Programming). . 3-11 3-8 Direct Parallel Connections . 3-13 3-9 Master/ Slave Connections, Parallel Operation. .
18、3-14 3-10 Direct Series Connections (Remote Sensing). . 3-15 3-11 Master/ Slave Connections, Series Operation. . 3-16 4-l Phase Control Firing Angles . 4-l 4-2 DCR-B Functional Block Diagram . 4-2 4-3 Passing Stage Principle . 4-4 5-l Performance Test Setup . 5-3 6-l DCR-B PCB Schematic Diagram . 6-
19、2 6-2 PCB Component Location Diagram . 6-4 6-3 Component Layout, Typical Assembly . 6-5 6-4 DCR lo-120B Schematic Diagram . 6-6 6-5 DCR 20-80B Schematic Diagram . 6-7 6-6 DCR 40-40B Schematic Diagram . 6-8 6-7 DCR 60-30B Schematic Diagram . 6-9 6-8 DCR 80-20B Schematic Diagram . 6-10 6-9 DCR 150-12B
20、 Schematic Diagram . 6-11 6-10 DCR 300-6B Schematic Diagram . 6-12 6-11 DCR 600-3B Schematic Diagram . 6-13 6-12 OVP PCB Schematic and Component Location . 6-19 6-13 D CR-B Outline Drawing . 6-21 LIST OF TABLES Table l-l 3-l 3-2 3-3 5-l 5-2 5-3 6-l 6-2 6-3 Title Page Specifications . . . . . . . . .
21、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-4 Front Panel Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 RA/RB Values-Two Identical DCR-B Units Series Connected. 3-17 Recommended Rectifiers, Series Operation. . . . . . . . . . . .
22、 . . . . . . . 3-17 DCR-B Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Sensing Resistor Values (Current Mode Regulation Check). . . . 5-5 Unit Calibration Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 Replaceable
23、 Parts List, DCR-B PCB Assembly. . . . . . . . . . . . . . . 6-3 Replaceable Parts List, DCR-B Main Assembly 1800 Watt Series 6-14 Replaceable Parts List, DCR-B OVP . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 V ._I.- SECTION 1 INTRODUCTION 1.1 INTRODUCTION This manual contains operati
24、on and maintenance data on the 1800 watt units of the DCR-B series Sorensen Power Supplies. It is intended to familiarize the user with the functioning of the unit, to introduce the varied applications to which the unit may be adapted, and to furnish sufficient maintenance data to assure long operat
25、ing life. Six major sections form the manual divisions. Section 1 contains a brief functional description of the DCR-B series power supplies. Initial inspection and checkout procedures are outlined in section 2. Operating instructions, including methods for adapting units to various applications, co
26、mprise section 3. Sections 4 and 5 provide the principles of operation and maintenance procedures respectively. System drawings and the replacement parts list are provided in section 6. 1.2 DESCRIPTION 1.2.1 General Designed for either bench or rack use, the typical DCR-B power supply pro- vides a h
27、ighly regulated, precise dc output, adjustable over a wide range. It operates from a nominal 115 Vat (208/220/230 Vat inputs are available as op- tions) and exhibits a rapid response to transients, both load and line. DCR-B series supplies are phase controlled type with SCRs (Silicon Controlled Rect
28、ifiers) or Triacs at the input to the transformer, followed by a passive LC filter. This design allows for a wide range of output voltages, simplicity of design, and offers large amounts of regulated power at relatively high efficiencies compared to linear regulators. Silicon type semiconductors are
29、 used extensively in DCR-B circuitry, and con- tribute significantly to the units wide ambient temperature range characteristic. Low dissipation transistors and diodes are located on a single printed circuit board while high dissipation devices are heat sinked to aluminum brackets and heat sinks. Al
30、l controls used during normal operation, except the OVP control, are mounted on the front panel. These include a power circuit breaker, FINE and COARSE VOLTAGE adjust potentiometers, and FINE and COARSE CURRENT adjust poten- tiometers. The system output is taken across a terminal pair at rear termin
31、al strip TB2. A variety of Sorensen power supply application notes are available through your Sorensen Service Representative. These notes detail many hook-up configurations and special usages available to meet most power supply applications. 1.2.2 Automatic Crossover There are two basic operating modes, voltage and current. In the voltage mode, the voltage is held constant while the current varies with the load. In the cur- Introduction l-l Rev C (l/85)