《SORENSEN DCR-B Series 1800-Watt Instruction Rev D 电路图.pdf》由会员分享,可在线阅读,更多相关《SORENSEN DCR-B Series 1800-Watt Instruction Rev D 电路图.pdf(67页珍藏版)》请在收音机爱好者资料库上搜索。
1、Sorensen Company Tel 603 666 4500 676 Island Pond Road Telex 943459 Manchester NH 03103 1509 TWX 710 220 1339 Sorensen A R-on Company Instruction Manual for DCR-B Series 1800-Watt Power Supplies Manual covers DCR-B models: 1011208 80-208 20-808 150-128 40-408 300-88 80-308 800-38 Document Number 165
2、041 Rev D (9165) RadioFans.CN 收音机爱 好者资料库 FIVE-YEAR WARRANTY Sorensen Company warrants all part8 of equipment of its mJnufJCture, except Jpeciai purpose tubeJ and Seml- conductor devices which carry their own mJnufacturerJ warranty, to be bee from defects caused by faulty material or poor workmanship
3、. Sorensen Compsny warrants Its products to conform to appllcabtecommercial or military specifications when confirmedon the Order Acknowledgment form to be free from defects caused by faulty material or poor workmanship. Sorensen Companys obligation is llmlted under the warranty to repair or replace
4、ment of products in kind, or at its option to issuance of a credit of orlglnal purchase prtce.Returns must be accompanied by a Sorensen Company Return Material Authorization form and conlorm to standard conditions for adjustment. The aforesaid warranty shall expire five (5) years following the last
5、day 01 the month of shipment from Sorensen Companys plant. The foregoing states the entlre warranty extended by Sorensen Company. No other warranty, expressed or implied, is made and, specifically, Sorensen Company makes no warranty of merchantability or fitness for any purpose. In no case shall Sor
6、ensen Company be liable lor any special or consequential damages. Authorization must be obtained prior to return of defective items. SORENSEN COMPANY RadioFans.CN 收音机爱 好者资料库 SECTION 1 1.1 1.2 - .- 1.3 1.4 SECTION 2 2.1 2.2 2.3 2.4 2.5 SECTION 3 3.1 3.2 TABLE OF CONTENTS INTRODUCTION INTRODUCTION . D
7、ESCRIPTION . 1.2.1 General . 1.2.2 Automatic Crossover . 1.2.3 Remote Sensing . 1.2.4 Series Operation . 1.2.5 Parallel Operation . 1.2.6 Remote Programming . 1.2.7 Unit Shutdown Circuit . 1.2.8 Protection Features . OPTIONAL MODIFICATIONS . SPECIFICATIONS . INSTALLATION GENERAL . INITIAL INSPECTION
8、 . ELECTRICAL INSTALLATION . MECHANICAL INSTALLATION . ELECTRICAL CHECK . 2.5.1 Voltage Mode . 2.5.2 Current Mode . OPERATION GENERAL . VOLTAGE MODE OPERATION . 3.2.1 Local Sensing . 3.2.2 Remote Sensing . 3.2.3 Resistance Programming . 3.2.4 Signal Programming . i Page l-l l-l l-l l-l 1-2 l-2 l-2 1
9、-2 l-2 l-2 1-3 l-3 2-l 2-l 2-l 2-l 2-2 2-2 2-2 3-l 3-4 3-4 3-4 3-6 3-8 . - . “._“.-1_-. _-. - RadioFans.CN 收音机爱 好者资料库 SECTION 3 3.3 3.4 3.5 3.6 3.7 SECTION 4 4.1 4.2 4.3 4.4 TABLE OF CONTENTS (Contd) OPERATION CURRENT MODE OPERATION . 3.3.1 Resistance Programming . 3.3.2 Signal Programming . 3.3.3 A
10、lternate Current Programming Method . PARALLEL OPERATION . 3.4.1 Direct Paralleling . 3.4.2 Master/ Slave Paralleling. . SERIES OPERATION . 3.5.1 Direct Series connections . 3.5.2 Master/ Slave Connections . UNIT SHUTDOWN CIRCUIT . OVP . 3.7.1 OVP Adjustment . THEORY OF OPERATION INTRODUCTION . PHAS
11、E CONTROL PRINCIPLE . BLOCK DIAGRAM ANALYSIS . DETAILED CIRCUIT DESCRIPTION . 4.4.1 Reference and Bias Supplies . 4.4.2 Voltage Mode Section . 4.4.3 Current Mode Section. . 4.4.4 Ramp Generator, Reset Circuit and Comparator 4.4.5 Blocking Oscillator $2 . 4.4.6 Turn-On and Shut-Down Circuits . 4.4.7
12、Power Section . 4.4.8 Overvoltage Protector . 4.4.9 Indicator Lamps . ii Page 3-8 3-9 3-10 3-10 3-12 3-12 3-13 3-14 3-14 3-16 3-18 3-18 3-18 4-l 4-l 4-3 4-3 4-3 4-4 4-5 4-5 4-6 4-6 4-6 4-7 4-7 - TABLE OF CONTENTS (Contd) SECTION 5 5.1 5.2 5.3 5.4 5.5 5.6 SECTION 6 6.1 6.2 MAINTENANCE GENERAL . PERIO
13、DIC SERVICING . TROUBLESHOOTING . CALIBRATION . 5.4.1 Current Mode Section, Limit Settings . PERFORMANCE TESTING . 5.5.1 Voltage Mode Regulation and Ripple . 5.5.2 Current Mode Regulation . 5.5.3 Transient Response . HI-POT TEST PROCEDURE . Page 5-l 5-l 5-l 5-l 5-2 5-3 5-3 5-4 5-4 5-5 DRAWINGS AND P
14、ARTS LISTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-l PARTS LIST COLUMN HEADINGS DEFINED. . . . . . . . . . . . . 6-l . . . 111 LIST OF ILLUSTRATIONS Figure Title Page 3-l DCR-B Controls and Indicators . 3-2 3-2 Control PCB Barrier Strip
15、 Connections . 3-3 3-3 Remote Sensing Connections . 3-5 3-4 Illustration of Load Lead Resistance (Remote Sensing). . 3-6 3-5 Voltage Mode Programming Connections . 3-7 3-6 Current Mode Programming Connections . 3-9 3-7 DCR-B Interconnections (Current Programming). . 3-11 3-8 Direct Parallel Connecti
16、ons . 3-13 3-9 Master/ Slave Connections, Parallel Operation. . 3-14 3-10 Direct Series Connections (Remote Sensing). . 3-15 3-11 Master/ Slave Connections, Series Operation . 3-16 4-l Phase Control Firing Angles . 4-l 4-2 DCR-B Functional Block Diagram . 4-2 4-3 Passing Stage Principle . 4-4 5-l Pe
17、rformance Test Setup . 5-3 6-l DCR-B PCB Schematic Diagram . 6-2 6-2 PCB Component Location Diagram . 6-4 6-3 Component Layout, Typical Assembly . 6-5 6-4 DCR lo-120B Schematic Diagram . 6-6 6-5 DCR 20-80B Schematic Diagram . 6-7 6-6 DCR 40-40B Schematic Diagram . 6-8 6-7 DCR 60-30B Schematic Diagra
18、m . 6-9 6-8 DCR 80-20B Schematic Diagram . 6-10 6-9 DCR 150-12B Schematic Diagram . 6-11 6-10 DCR 300-6B Schematic Diagram . 6-12 6-11 DCR 600-3B Schematic Diagram . 6-13 6-12 OVP PCB Schematic and Component Location . 6-19 6-13 D CR-B Outline Drawing . 6-21 iv LIST OF TABLES Table l-l Specification
19、s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-4 3-l Front Panel Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-2 RA/RB Values-Two Identical DCR-B Units Series Connected. 3-17 3-3 Recommended Rectifiers, Series O
20、peration. . . . . . . . . . . . . . . . . . . . 3-17 5-l DCR-B Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5-2 Sensing Resistor Values (Current Mode Regulation Check). . . . 5-5 5-3 Unit Calibration Specifications . . . . . . . . . . . . . . . . .
21、. . . . . . . . . . . . . . . 5-5 6-1 Replaceable Parts List, DCR-B PCB Assembly. . . . . . . . . . . . . . . 6-3 6-2 Replaceable Parts List, DCR-B Main Assembly 1800 Watt Series 6-14 6-3 Replaceable Parts List, DCR-B OVP l .*.*.*.*.*. 6-20 Title Page “L I , I V SECTION 1 INTRODUCTION .ma - , *- - -
22、 I , - - 1.1 INTRODUCTION This manual contains operation and maintenance data on the 1800 watt units of the DCR-B series Sorensen Power Supplies. It is intended to familiarize the user with the functioning of the unit, to introduce the varied applications to which the unit may be adapted, and to fur
23、nish sufficient maintenance data to assure long operating life. Six major sections form the manual divisions. Section 1 contains a brief functional description of the DCR-B series power supplies. Initial inspection and checkout procedures are outlined in section 2. Operating instructions, including
24、methods for adapting units to various applications, comprise section 3. Sections 4 and 5 provide the principles of operation and maintenance procedures respectively. System drawings and the replacement parts list are provided in section 6. 1.2 DESCRIPTION 1.2.1 General Designed for either bench or r
25、ack use, the typical DCR-B power supply pro- vides a highly regulated, precise dc output, adjustable over a wide range. It operates from a nominal 115 Vat (208/220/230 Vat inputs are available as op- tions) and exhibits a rapid response to transients, both load and line. DCR-B series supplies are ph
26、ase controlled type with SCRs (Silicon Controlled Rectifiers) or Triacs at the input to the transformer, followed by a passive LC filter. This design allows for a wide range of output voltages, simplicity of design, and offers large amounts of regulated power at relatively high efficiencies compared
27、 to linear regulators. Silicon type semiconductors are used extensively in DCR-B circuitry, and con- tribute significantly, to the units wide ambient temperature range characteristic. Low dissipation transistors and diodes are located on a single printed circuit board while high dissipation devices
28、are heat sinked to aluminum brackets and heatsinks. All controls used during normal operation, except the OVP control, are mounted on the front panel. These include a power circuit breaker, FINE and COARSE VOLTAGE adjust potentiometers, and FINE and COARSE CURRENT adjust poten- tiometers. The system
29、 output is taken across a terminal pair at rear terminal strip TB2. A variety of Sorensen power supply application notes are available through your Sorensen Service Representative. These notes detail many hook-up configurations and special usages available to meet most power supply applications. 1.2.2 Automatic Crossover There are two basic operating modes, voltage and current. In the voltage mode, the voltage is held constant while the current varies with the load. In the cur- c* = Introduction l-l Rev C (l/85)