1、Operation Manual Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of

2、the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. The information provided in this manual was deemed accurate as of the publication date. However, updates to this information ma

3、y have occurred. To obtain the latest version of this manual, please visit the Crown website at . Trademark Notice: Crown, Crown Audio, IQ, IQ System, BCA, and Amcron are registered trademarks of Crown International. IQwic and TCP/IQ are trademarks of Crown International. HiQnet is a trademark of Ha

4、rman International Industries, Inc. Other trademarks are the property of their respective owners. Some models may be exported under the name Amcron. 2007 by Crown Audio Inc., 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000 I-Tech Series 137289-10 11/07 I-T4000 I-T60

5、00 I-T8000 RadioFans.CN 收音机爱 好者资料库 Operation Manual I-Tech Series Power Amplifiers page 2 1)Read these instructions. 2)Keep these instructions. 3)Heed all warnings. 4)Follow all instructions. 5)Do not use this apparatus near water. 6)Clean only with a dry cloth. 7)Do not block any ventilation openin

6、gs. Install in accordance with the manufacturers instructions. 8)Do not install near any heat sources such as radiators, heat reg- isters, stoves, or other apparatus (including amplifiers) that produce heat. 9)Do not defeat the safety purpose of the polarized or grounding- type plug. A polarized plu

7、g has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10)Prote

8、ct the power cord from being walked on or pinched, par- ticularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11)Only use attachments/accessories specified by the manufac- turer. 12)Use only with a cart, stand, tripod, bracket, or table specified by the manuf

9、acturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13)Unplug this apparatus during lightning storms or when unused for long periods of time. 14)Refer all servicing to qualified service personnel. Servicing i

10、s required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate nor- mally, or has been dropped. 15)Use the mains plug to d

11、isconnect the apparatus from the mains. 16)WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 17)DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, ARE PLACED ON THE EQUIP- MENT. 1

12、8)THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. PRVENIR LE CHOC LECTRIQUE NENLEVEZ PAS LES COUVERCLES. IL NY A PAS DES PARTIES SERV

13、ICEABLE LINTRIEUR. TOUS REPARATIONS DOIT ETRE FAIRE PAR PERSONNEL QUALIFI SEULMENT. PARA PREVENIR UN CHOQUE ELCTRICO, NO RETIRE LAS CUBIERTAS SUPERIOR O INFERIOR. NO EXISTEN PARTES QUE PUEDAN SER REPARADAS POR EL USUARIO AL INTE- RIOR. REMITA EL SERVICICO AL PERSONAL TCHNICAL CALIFICADO. TO COMPLETE

14、LY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE. POUR DMONTER COMPLTEMENT LQUIPEMENT DE LALIMENTATION GNRALE, DMONTER LE CBLE DALI- MENTATION DE SON RCEPTACLE. LA PRISE

15、 DALIMEN- TATION RESTERA AISMENT FONCTIONNELLE. PARA DESCONECTAR COMPLETAMENTE EL EQUIPO DEL SUMINSTRO ELECTRICO, DESCONECTE EL CABLE DE ALI- MENTACION DE LA TOMA DE CA. LAS PATAS DEL CONEC- TOR DEL CABLE DE ALIMENTACIN DEBERAN MANTENERSE EN BUEN ESTADO. WATCH FOR THESE SYMBOLS: The lightning bolt t

16、riangle is used to alert the user to the risk of electric shock. The exclamation point triangle is used to alert the user to important operating or maintenance instructions. REGARDEZ CES SYMBOLES La triangle avec le sigle foudre est employe pour alerter lutilisateur au risque de dcharge lectrique. L

17、e triangle avec un point dexclamation est employe pour alerter lutilisateur dinstruction importantes pour lors oprations de mainte- nance. ATENCION CON ESTOS SMBOLOS El tringulo con el smbolo de rayo elctrico es usado para alertar al usuario de el riesgo de un choque elctrico. El tringulo con el sig

18、no de admiracin es usado para alertar al usuario de instrucciones importantes de operacin o man- tenimiento. Important Safety Instructions FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause har

19、mful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: Thi

20、s equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate r

21、adio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to r

22、adio or televi- sion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Con

23、nect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IMPORTANT I-Tech Series amplifiers require Class 2 output wiring. Les amplificateurs de srie de I-Tech exigent des cbles de sortie

24、 de classe 2. I-Tech-Reihe-Verstrker verlangen Klasse die 2 Produktionsver- drahtung. Los amplificadores de la Serie I-tech requieren de un cableado de salida Clase 2. MAGNETIC FIELD CAUTION! Do not locate sensitive high-gain equipment such as preamplifiers or tape decks directly above or below the

25、unit. Because this amplifier has a high power density, it has a strong magnetic field which can induce hum into unshielded devices that are located nearby. The field is strongest just above and below the unit. If an equipment rack is used, we recommend locating the ampli- fier(s) in the bottom of th

26、e rack and the preamplifier or other sensi- tive equipment at the top. Instrucciones de Seguridad ImportantesImportantes Instructions de Scurit Wichtige Sicherheitsinstruktionen The I-Tech Series amplifiers are certified only at 120V in Canada. RadioFans.CN 收音机爱 好者资料库 I-Tech Series Power Amplifiers

27、Operation Manualpage 3 DECLARATION of CONFORMITY Crown International, Inc. Sue Whitfield 574-294-8289 European Representatives Name and Address: David Budge 10 Harvest Close Yateley GU46 6YS United Kingdom Equipment Type: Commercial Audio Power Amplifiers Family Name: I-Tech Model Names: I-T4000, I-

28、T6000, I-T8000 EMC Standards: EN 55103-1:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions EN 55103-1:1997 Magnetic Field Emissions-Annex A 10 cm and 20 cm EN 61000-3-2:2001

29、 Limits for Harmonic Current Emissions (equipment input current less than or equal to 16 A per phase) EN 61000-3-3:2002 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current less than or equal to16A EN 55022:2003 Limits and Methods of Measurement of Radio Disturb

30、ance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class A EN 55103-2:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity EN 61000-4-2:2001 Electrostatic Dischar

31、ge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge) EN 61000-4-3:2001 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A) EN 61000-4-4:2001 Electrical Fast Transient/Burst Immunity (Criteria B) EN 61000-4-5:2001 Surge Immunity (Criteria B) EN 61000-

32、4-6:2003 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A) EN 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variation Safety Standard: IEC 60065: 2001 7th Ed. Safety Requirements - Audio Video and Similar Electronic Apparatus I certify that the product

33、 identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC. Signed Title: Senior Vice President of Manufacturing Date of Issue: May 1, 2004 ISSUED BY: Crown International, Inc. 1718 W

34、. Mishawaka Road Elkhart, Indiana 46517 U.S.A. Due to line current harmonics, we recommend that you contact your supply authority before connection. FOR COMPLIANCE QUESTIONS ONLY: RadioFans.CN 收音机爱 好者资料库 Operation Manual I-Tech Series Power Amplifiers page 4 Getting Started With I-Tech Welcome! Oper

35、ating your I-Tech amplifier can be as simple or advanced as you wish. Right out of the box, it works like any other amplifier with stereo loudspeaker loads. For bridge-mono operation, see page 5. If you want to control and monitor the amplifier with Crowns IQ System software, see Section 4.5.4. If y

36、ou are going to use SystemArchitect, please follow the information included with System Architect. If you want to load DSP presets or perform diagnostics using the amplifiers LCD control screen (Figure A.3), see Section 4.2. You can refer to this Quick-Start Guide to get up and running quickly. To l

37、earn about I-Techs many advanced features, please see the rest of this manual. Quick-Start Guide: Stereo Wiring Lets assume that you unpacked and installed your amplifier with the proper cooling. If not, see Section 2 in this manual. Well also assume that you will operate the amplifier in stereo. If

38、 you want to operate your amplifier in bridge-mono, skip to page 5. 1. IMPORTANT: Turn off the amplifier. Unplug its power cord from the AC outlet. The amplifier must be grounded when plugged into AC power. 2. See Figure A.1. Connect two cables from your mixer output to the amplifiers XLR input con-

39、 nectors. 3. Using Class 2 wiring, connect speaker cables either to the amplifiers Speakon connectors (as in Figure A.2) or to the binding posts (as in Figure A.1.) 4. Turn down your mixer master faders. Plug the power cord into the amplifier and then into an AC outlet. Turn on the front-panel power

40、 switch. The LCD Control Screen will light up (Figure A.3). 5. Using both Encoder knobs (Level controls), set Attenuation to 0 dB. Press the Menu/Exit button, then the Next button, to access CH1 Sensitivity. Turn an Encoder knob fully down (CCW) until the minimum dB gain is displayed. Then press Nex

41、t and repeat for CH2 Sensitivity. See Appendix B for details. 6. Play a program through your mixer. Set its level to peak at 0 dB or 0 VU maximum on the mixer meters. Gradually turn up (CW) the amplifier Encoder knobs (Level controls) to the desired volume for CH2. Press Prev and repeat for CH1. Pre

42、ss Exit when done. Note: If the SPL is too high at the beginning of Step 6, press Menu/Exit, then press Next until you see ADVANCED MENU. Push an Encoder knob. Press Next until you see MAXIMUM ANA- LOG INPUT. Press an Encoder knob so the display reads 21 dBu. Press Menu/Exit twice. Press Next. CH1 S

43、ensitivity will be displayed. Gradually turn up (CW) the left Encoder knob to the desired volume for CH1. Press Next and repeat for CH2. Press Exit when done. Channel 1 Loudspeaker Channel 2 Loudspeaker Top Speakon (Channel 1) Bottom Speakon (Channel 2) Figure A.2 Wiring Two Speakers to Two Speakon

44、Con- nectors for Stereo Operation Figure A.3 The LCD Control Screen CAUTION SHOCK HAZARD: Potentially lethal voltages exist at the output connec- tors when the amplifier is turned on and is passing a signal. Figure A.1 Rear-panel Connections for Stereo Wiring I-Tech Series Power Amplifiers Operation

45、 Manualpage 5 Quick-Start Guide: Bridge-Mono Wiring Lets assume that you unpacked and installed your amplifier with the proper cooling. If not, see Section 2 in this manual. Well also assume that you will operate the amplifier in Bridge- Mono. Basically you will turn on the amp, enable Bridge-Mono m

46、ode with the LCD Control Screen, turn off the amp, wire it, and turn it back on. 1. Be sure that no cables are connected to the amplifier. Plug the amplifier power cord into the amplifier, then into an AC outlet. 2. Turn on the amplifier power switch on the front panel. The LCD Control Screen will l

47、ight up (Figure A.4). 3. Under the LCD Control Screen, press the Menu/Exit button. Press the Next button until you see Output Mode on the screen. 4. Press either Encoder knob to select BRIDGE MONO. Press and hold the knob to confirm your choice. Press the Menu/Exit button. 5. IMPORTANT: Turn off the

48、 amplifier. Unplug its power cord from the AC out- let. The amplifier must be grounded when plugged into AC power. 6. See Figure A.5. Connect a cable from your mixer output to the amplifiers Channel-1 XLR input connector. 7. Using Class 2 wiring, connect the speaker cable either to the amplifiers to

49、p Speakon connector (terminals 1+ and 2+, Figure A.6) or across the red binding posts of both channels (Figure A.5). Do not use the black binding posts in bridge-mono mode. 8. Turn down your mixer master faders. Plug the power cord into the amplifier and then into an AC outlet. Turn on the front-panel power switch. The LCD Control Screen will light up (Figure A.3). 9. Using both Encoder knobs (Level controls), set Attenuation to 0 dB. Press the Menu/ Exit button, then the Next button, to access CH1 Sensi