1、 Document type: Created: Page: SERVICE BULLETIN (2009-04-08) Page 1 of 4 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1, S-434 44 KUNGSBACKA, SWEDEN |. Technical Service Bulletin No. 13

2、THIS BULLETIN REPLACES BULLETIN NO. 3 AND NO. 7 Pot FP Plus Created by: Lab.gruppen AB Service Department Date: 090408 Reference no: Pot FP Plus Affected models Following models are affected by this technical service bulletin: FP 6000Q FP 7000 FP 10000Q FP 13000 Affected boards/modules UI12Lx203, PO

3、T2B, UI12Lx403, POT4C. Symptom Distortion or dead channel due to bad potentiometers. Potentiometer VR10KLIN31HSBF replaces potentiometer VR10KLIN21H since the 21-step potentiometer has bad quality. When doing service on a FP+ Series amplifier the potentiometers shall be exchanged if a POT-board with

4、 the old type of potentiometers is mounted. See picture below on how to identify the old type of potentiometer. Solution UI12Lx203 and POT2B needs to be changed to UI12Lx205 and POT2B04 to get the new potentiometers to fit. UI12Lx403 and POT4C needs to be changed to UI12Lx405 and POT4C03 to get the

5、new potentiometers to fit. RadioFans.CN 收音机爱 好者资料库 Document type: Created: Page: SERVICE BULLETIN (2009-04-08) Page 2 of 4 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1, S-434 44 KUNGSB

6、ACKA, SWEDEN |. Note Old potentiometers (see picture 1 below) have plastic axis (black) and the new potentiometer have a steel axis. Both POT-board and UI-board needs to be exchanged since the new POT- board does not fit with the old UI-board. If the potentiometer VR10KLIN31_TOK (see picture 2 below

7、) is mounted those does not need to be replaced, only potentiometers with plastic axis needs to be replaced. Difference between VR10KLIN31_TOK and VR10KLIN31HSBF is the supports on the sides. Picture below shows difference between old and new potentiometers. Picture 1: Old type of potentiometers. Pi

8、cture 2: The VR10KLIN31_TOK potentiometer. RadioFans.CN 收音机爱 好者资料库 Document type: Created: Page: SERVICE BULLETIN (2009-04-08) Page 3 of 4 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1,

9、 S-434 44 KUNGSBACKA, SWEDEN |. Picture 3: The VR10KLIN31HSBF potentiometer. Picture 4: The VR10KLIN31HSBF potentiometer, solder side. RadioFans.CN 收音机爱 好者资料库 Document type: Created: Page: SERVICE BULLETIN (2009-04-08) Page 4 of 4 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE W

10、RITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1, S-434 44 KUNGSBACKA, SWEDEN |. Part numbers Model Part number to be ordered FP 6000Q VR10KLIN31HSBF, UI12Lx405, POT4C03, MH2x81ML, SUI12Lx4FP6KQ02, BUI, 2pcs SSDS5x72 FP 7000 VR10KLIN31HSBF, UI12Lx205, POT2B

11、04, MH2x81ML, SUI12Lx2FP7K02, BUI, 2pcs SSDS5x72 FP 10000Q VR10KLIN31HSBF, UI12Lx405, POT4C03, MH2x81ML, SUI12Lx4FP10KQ04, BUI, 2pcs SSDS5x72 FP 13000 VR10KLIN31HSBF, UI12Lx205, POT2B04, MH2x81ML, SUI12Lx2FP13K04, BUI, 2pcs SSDS5x72 History Date Created By Status Bulletin no. Comment 080930 JF DISCONTINUED 7 REPLACED BY BULLETIN NO. 13 090408 PB SHARP 13