1、3 RadioFans.CN 收音机爱 好者资料库 23 Unrelenting quality standards Within a decade, Lab.gruppen had expanded to become a major supplier of power amplifiers throughout Europe, and started making significant inroads into the world market. Demand often threatened to outstrip supply, but quality control standar

2、ds never were compromised in order to increase production levels. With every new product, and at every stage of expansion, Lab.gruppen took pride in maintaining the highest levels of traditional Swedish craftsmanship. Only after a larger and highly efficient manufacturing facility still in Kungsback

3、a came online was product distribution fully expanded worldwide. Lab.gruppen continued to build on its foundation in touring sound applications with the pristine sound and bulletproof reliability of the fP Series. With introduction of the FP+ Series Lab.gruppen dramatically boosted power density and

4、 added compatibility with NomadLink network control. Responding to increasing demand from the systems integration market, Lab.gruppen introduced the C Series, a range of multi-channel units designed and fitted for installation applications also featuring NomadLink control. Lab.gruppen + Lake: The ul

5、timate in power and control In 2006, Dolby Laboratories and Lab.gruppen announced an agreement to incorporate Lake Processing into the forthcoming PLMTM Series of Powered Loudspeaker ManagementTM systems. The first Lab.gruppen product to incorporate Lake processing, the PLM 10000Q, was introduced in

6、 2007. When Dolby decided to exit the live sound market, Lab.gruppen acquired both the Lake trademarks and exclusive rights for use of Dolby Lake Processor technology for the touring and permanent sound reinforcement markets. Both divisions are now headquartered in Kungsbacka. First drawing of Class

7、 TD circuit by Kenneth Andersson Lab.gruppen co-founder Kenneth Andersson Lab.gruppen co-founder Dan Bavholm Passion, innovation and Swedish craftsmanship In 1979, Kenneth Andersson and Dan Bavholm established Lab.gruppen while working out of a cramped electronics repair shop in Kungsbacka, Sweden.

8、With a knack for creative circuit design and a passion for better sound, they set about developing new audio products beginning with guitar amplifiers that soon evolved into highly regarded professional power amplifiers. Within a remarkably short time, Lab.gruppen had built a loyal customer base amo

9、ng leading Swedish sound rental companies. Not content with merely refining existing designs, the founders continually pushed the envelope of audio amplifier design. New technologies boosted output power while at the same time reducing weight and improving reliability under stress. Noteworthy among

10、these developments were the patented Class TD output stage, Regulated Switch Mode Power Supply (R.SMPS), the Intercooler heat dispersion system, and innovative limiter circuits that tailor amplifier output parameters for optimum performance with the connected load. RadioFans.CN 收音机爱 好者资料库 54 Cutting

11、 edge amplifier development Lab.gruppen power amplifiers and PLM Series Powered Loudspeaker Management systems have earned worldwide recognition for outstanding sound quality and remarkable durability in both touring and installed applications. At the core of this enviable reputation is Lab.gruppens

12、 commitment to innovation, firmly established by the company founders and continuing with todays extensive R the amplifiers simply use the dynamic behavior of the input signal and “recharge” between the peaks. Lowering the “electricity penalty” With already high energy costs moving higher in nearly

13、every part of the world, the total amount of electricity required to power an amplifier must be factored in to the total cost of ownership and operation. When electricity costs are factored into the equation, Lab.gruppen E Series amplifiers quickly recoup any marginally higher initial costs within t

14、he first few years of operation, when compared to several popular installation amplifiers using conventional technologies. Depending on the specific application and on/off cycle periods, conventional amplifiers may impose an “electricity penalty” up to three times that of the E Series. Many of them

15、will cost more in electricity over 6 years of use than they initially cost to purchase! Lab.gruppens amplifier platforms, often in combination with Lake technology, can be found the world over and across a multitude of applications ranging from arena or night club installations to touring concert so

16、und. Integration is at the heart of the product range. Realizing the performance advantages of Lab.gruppen products is hassle-free, whatever the system configuration and irrespective of the other components. In touring sound, the seamless integration of Lake Processing and Lab.gruppen amplification

17、powered the excitement of U2s globe-spanning 360 tour, with more than 150 PLM Series Powered Loudspeaker Management systems driving Clair loudspeaker arrays. In the installation market, the PLM Series brought the same advantages to BC Place in Vancouver, Canada, where the former Olympic venue employ

18、s 160 PLM Series units. The advantages of Lake Processing and Lab.gruppen amplification are often realized when coupled to loudspeakers from sister company Tannoy. A recent example is at Englands famed Ascot Racecourse, where PLM Series units drive a loudspeaker system comprising of Tannoy V Series,

19、 VQ Series and QFlex. Here, the combination of Lab.gruppen and Tannoy delivered measurable performance, reliability and cost advantages that simply couldnt be achieved by alternative configurations. This approach is echoed in smaller installations, such as retail outlets, bars, clubs and restaurants

20、. At Californias Cannery Row Brewing Company, the combination of Lab.gruppen C Series amplifiers along with Tannoy surface-mount and ceiling speakers contribute to a festive atmosphere that builds repeat business. Regardless of the product configuration Powered Loudspeaker Management systems, discre

21、te amplifiers with separate Lake processors , or Lab.gruppen amplifiers integrated into Tannoy VXP powered loudspeakers Lab.gruppens “power to integrate” brings performance and cost-saving advantages to any audio system. Lake, NomadLink, Class TD and Intercooler are national and/or international reg

22、istered trademarks of Lab.gruppen AB. R.SMPS, VPL, ISVPL, PLM, Powered Loudspeaker Management, LoadSmart, LoadLibrary, SpeakerSafe, IDEEA and RSL are trademarks of Lab.gruppen AB. Dante and Zen are trademarks of Audinate Pty Ltd. Dolby is a registered trademark of Dolby Laboratories. Raised Cosine E

23、qualization, Iso-Float, Contour Pro 26, Mesa Quad EQ, and LimiterMax are trademarks of Dolby Laboratories. All other trademarks remain the property of their respective owners. Copyright 2011 Lab.gruppen AB. All rights reserved. Power to integrate 20 Item no. FLC-2011 L A B .G R U P P E N A B S W E D

24、 E N I N T E R N AT I O N A L C O N TAC T I N F O L A B G R U P P E N .C O M U S Power Average Limiter (PAL)2); Power on NomadLink Network; Power Average Limiter (PAL)2); Power on Signal present / High-impedance; -10 dB and -4 dB output signal;Voltage Peak Limiter (VPL); Current Peak Limiter (CPL):

25、Very High Frequency (VHF); High temperature; Fault; Mute Signal present / High-impedance; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute 130-265 V / 65 -135 V 6)Universal power supply 65-265 V 171 V / 85 V80 V YesYes No Yes Yes / max.

26、 5 AYes / max. 5 A 230 V CE: 16 A, CEE7; 115 V ETL: 20 A / NEMA 5-20P; C16:4: 15A/NEMA 5-15PIEC Inlet W: 483 mm (19”), H: 88 mm (2 U), D: 343 mm (13.5”)W: 483 mm (19”), H: 88 mm (2 U), D: 343 mm (13.5”) 12 kg (26.4 lbs.)8.5 kg (18.75 lbs.) Black painted steel chassis with gray painted steel frontBla

27、ck painted steel chassis with gray painted steel front CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCCCE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC Specifi cations C Series Model Number of channels Peak total output all channels driven Peak output voltage per channel Max. output current per ch

28、annel Max. Output Power 16 ohms per ch. (all ch.s driven) 8 ohms per ch. (all ch.s driven) 4 ohms per ch. (all ch.s driven) 2 ohms per ch. (all ch.s driven) 16 ohms Bridged per ch. 8 ohms Bridged per ch. 4 ohms Bridged per ch. 2 ohms Bridged per ch. Performance with Gain: THD 20 Hz - 20 kHz for 1 W0

29、.1% THD at 1 kHz and 1 dB below clipping112 dB Channel separation (Crosstalk) at 1 kHz70 dB Frequency response (1 W into 8 ohms) +0/-3 dB Input Impedance20 kOhm Common Mode Rejection (CMR)54 dB, 20 Hz to 20 kHz Output impedance 100 Hz Voltage Peak Limiter (VPL), max. peak output VPL, selectable per

30、ch. (V) VPL, selectable when bridged (V) 1) Voltage Peak Limiter mode (per ch.)Hard / Soft Gain and Level Amplif er gain selectable (all channels) 1) rear-panel switches 23, 26, 29, 32, 35, 38, 41, 44 dB Default gain Level adjustment (per ch.)Front-panel potentiometer, 31 position detented from -inf

31、 to 0 dB Connectors and switches Input connectors (per ch.)3-pin XLR, electronically balanced Output connectors (per ch.)Neutrik speakON or Binding Posts (must be specified upon order). BP only on FP 14000, FP 9000. Output bridge mode per two ch.sA+B - Ch. A is signal input source. A+B, C+D - Ch.s A

32、 and C are input source NomadLink network2 x RJ45 etherCON connectors, IN and OUT Intelligent fans (on/off)Yes, depending on presence of output signal Power on/off and Remote enable on/offIndividual switches on front-panel CoolingTwo fans, front-to-rear airf ow, temperature controlled speed Front-pa

33、nel indicators CommonNomadLink network; Power Average Limiter (PAL) 2); Power on Per channelSignal present / High-impedance; -20 dB, -15 dB, -10 dB and -4 dB output signal; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute Power Operatin

34、g voltage, 230 V / 115 V nominal 4)130-265 V / 65-135 V Minimum power-up voltage, 230 V / 115 V171 V / 85 V Power Average Limiter (PAL) 2)Yes Soft start / Inrush Current DrawYes / max. 5 A Mains connector230 V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock | FP 4000: 230 V CE: 16 A, CEE7; 115 V ETL: 20

35、A / NEMA 5-20P DimensionsW: 483 mm (19”), H: 88 mm (2 U), Overall D: 396 mm (15.6”), Mounting D: 358 mm (14.1”) Weight12 kg (26.4 lbs.) FinishBlack painted steel chassis with black painted steel / aluminum front ApprovalsCE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC Note 1): Automatic -6 dB gain

36、 compensation when bridging channels. Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker. Refer to the FP+ Operation Manual section 7 .5.8 Power Average Limiter (PAL) for more information. No

37、te 3): The amplifier will be fully operational at bridge-mode 2 ohm loads, but due to physical constraints in the construction, the max. output power will not be significantly higher than running individual channels and therefore not stated here. Note 4): Separate 230 V or 115 V versions available.

38、Not selectable on the amplifier. All specifications are subject to change without notice. FP 14000FP 9000FP 7000FP 4000FP 10000QFP 6000Q 222244 14000 W9000 W7000 W4000 W10000 W6000 W 195 V170 V155 V121 V150 V101 V 90 A peak70 A peak59 A peak50 A peak50 A peak38 A peak 1200 W800 W730 W400 W660 W320 W

39、 2350 W1600 W1450 W800 W1300 W625 W 4400 W3000 W2800 W1600 W2100 W1250 W 7000 W4500 W3500 W2000 W2500 W1500 W 4700 W3200 W2900 W1600 W2600 W1250 W 8800 W6000 W5600 W3200 W4200 W2500 W 14000 W9000 W7000 W4000 W5000 W3000 W 3) 3) 3) 3) 3) 3) 35 dB and VPL: 195 V35 dB and VPL: 170 V35 dB and VPL: 155 V

40、35 dB and VPL: 121 V35 dB and VPL: 150 V35 dB and VPL: 101 V 2 Hz - 34.2 kHz2 Hz - 34.2 kHz6.8 Hz - 34 kHz2 Hz - 34.2 kHz6.8 Hz - 34 kHz6.8 Hz - 34 kHz 19 mOhm 19 mOhm19 mOhm32 mOhm32 mOhm32 mOhm 195, 170, 140, 116, 100, 80, 66, 54 V 170, 140, 116, 100, 80, 66, 54 V 155, 121, 101, 83, 70, 56, 47, 38

41、 V 121, 101, 83, 70, 56, 47, 38 V 150, 121, 101, 83, 70, 56, 47, 38 V 101, 83, 70, 56, 47, 38 V 390, 340, 280, 232, 200, 160, 132, 108 V 340, 280, 232, 200, 160, 132, 108 V 310, 242, 202, 166, 140, 112, 94, 76 V 242, 202, 166, 140, 112, 94, 76 V 300, 242, 202, 166, 140, 112, 94, 76 V 202, 166, 140,

42、112, 94, 76 V 38 dB38 dB35 dB35 dB35 dB35 dB Specifi cations FP+ Series Specifi cations PLM Series Model Number of input channels Number of output channels Peak total output all channels driven Max. Peak output voltage per channel Max. output current per channel Max. Output Power 16 ohms per ch. (al

43、l ch.s driven) 8 ohms per ch. (all ch.s driven) 4 ohms per ch. (all ch.s driven) 1) 2 ohms per ch. (all ch.s driven) 1) All channels driven into optimal impedance interval 8 ohms bridged per ch. 4 ohms bridged per ch. Bridged into optimal impedance interval Audio Performance THD + N 20 Hz - 20 kHz f

44、or 1 W0.05% THD + N at 1 kHz and 1 dB below clipping74 dB, 20 Hz to 20 kHz Internal sample rate96 kHz Internal data path32 bit f oating point Product propagation delay, best case (96 kHz AES)1.61 ms Product propagation delay, analog input1.68 ms Sample Rate Converters THD + Noise0.00003 %, 20 Hz - 2

45、0 kHz, unweighted Analog to Digital inputs Inputs2 inputs x 2 link Input sensitivity settings+12 or +26 dBu THD + Noise0.00022 %, typical at 1 kHz unweighted at +26 dBu headroom setting 0.00033 %, typical at 20 Hz and 20 kHz unweighted at +26 dBu headroom setting AES / EBU inputs Inputs2 inputs x 2

46、link Supported resolutions 24 bit Supported sample rates44.1, 48, 88.2, 96, 176.4, 192 kHz Dante Audio Network Inputs and outputs2 inputs, 2 outputs Supported sample rates48, 96 kHz Supports redundant pathsYes Flexible topologyYes Network latency0.8, 1.3 and 4 ms Device presets Local memory location

47、s for the settings of the product100 Limiters Adjustable Inter-Sample Voltage Peak Limiter (ISVPL) Current Peak Limiter 300 ms LimiterMax (rms and peak limiters) MaxRMS (rms voltage limiter)Yes MaxPeak (peak voltage limiter)Yes Gain Amplif er gain22 - 44 dB, step size 0.1 dB Output attenuator-Inf to

48、 0 dB, step size 0.25 dB Rear-panel interface AES / EBU / I/O (input + link)2 x 3-pin XLR Analog, 2-channel I/O (input + link)4 x 3-pin XLR, electronically balanced Output connectors Auto 10/100, Auto Uplink2 x RJ45 etherCON Control and monitoring interfaceVia Ethernet for Lake Controller software,

49、or DLM (the 3rd Party Protocol) Detachable mains cordNeutrik powerCON 32 A Cooling Front-panel user interface Display2.5 inch, daylight readable LCD Fault/Warning/Limit/Clip indicatorsRGB LEDs and detailed fault description on display Mute and soft function buttons8 provided Standby Power buttonOn/Standby Mute Enable buttonEnables muting of outputs and inputs via soft-button keypad Meter buttonToggles through meter views Menu buttonProvides a menu driven interface for full function front panel control Rotary EncoderY