《klark teknik DN3601C电路图.pdf》由会员分享,可在线阅读,更多相关《klark teknik DN3601C电路图.pdf(40页珍藏版)》请在收音机爱好者资料库上搜索。
1、Operators & Service Manual DN3601C Version 3.0C TELEX PRO AUDIO GROUP Klark Teknik Building Walter Nash Road, Kidderminster Worcestershire DY11 7HJ England Tel: (01562)741515 Fax: (01562)745371 RadioFans.CN 收音机爱 好者资料库 1 CONTENTS DECLARATION OF CONFORMITY 3 INTRODUCTION 8 INSTALLATION 9 INSTRUMENT FA
2、MILIARISATION 10 MASTER/SLAVE OPERATION 11 REFERENCE SECTION: DETAILS OF OPERATION 13 DEFAULT/START UP 13 FADER ADJUSTMENT 13 GAIN ADJUSTMENT 13 CURVE/FADER 13 MORE EQ 14 A : B : LINK 14 UTILITIES 14 BYPASS AND RESET 14 MORE EQ MENU AND DISPLAY 15 FILTERS 15 A : B 15 IN/OUT 15 EXIT 15 FILTER ADJUST
3、16 NOTCH1/2 16 16 BACK 16 UTILITIES MENU 17 AUTO/Q 17 MEMORY 17 MORE. 17 EXIT 17 AUTO/Q MENU 18 AUTO GAIN 18 AUTO EQ 18 Q TYPE 18 EXIT 18 MEMORY/LOCKOUT MENU 19 RECALL 19 SAVE 19 LOCK 20 FULL 20 RadioFans.CN 收音机爱 好者资料库 2 PARTIAL 20 EXIT 20 MORE. MENU 21 SLAVES 21 STAND ALONE 21 ALL 21 SLAVES 1 TO 64
4、 21 MIDI CHAN 21 INV LCD 21 EXIT 21 TECHNICAL SPECIFICATION 22 MENU STRUCTURE 23 SERVICE INFORMATION: FUSE SPECIFICATION 25 MIDI CONNECTIONS 26 SCHEMATIC DIAGRAMS RadioFans.CN 收音机爱 好者资料库 3 DECLARATION OF CONFORMITY The Directive Covered by this Conformity 89/336/EEC Electromagnetic Compatibility Dir
5、ective, amended by 92/31/EEC & 93/68/EEC. 73/23/EEC Low Voltage Directive, amended by 93/68/EEC. The Products Covered by this Declaration Equipment TypeProduct NameVariants Graphic EqualiserDN300DN360, DN301, DN332 Preset EqualiserDN320DN330 Parametric EqualiserDN405DN410 Dynamics ProcessorDN500DN50
6、4, DN510, DN514 Audio AnalyserDN6000 CrossoverDN800 Delay LineDN7204DN7103 Programmable EqualiserDN3600DN3601 Remote Control SystemDN3698DN3603 CrossoverDN8000 Programmable EqualiserDN4000 The Basis on which Conformity is being Declared The Products named above and hence the Variants thereof listed
7、above comply with the requirements of the above EU directives by meeting the following standards: EN 50081-1 (EN55022 class B) EN 50082-1 (IEC801 Part 2, 4 / ENV 50140 / ENV 50141 EN 60065. Signed:.N. G. Tembe Authority:Head of Engineering, EVI Audio (U.K.) Plc Date:1st January 1997 Attention! The a
8、ttention of the specifier, purchaser, installer or user is drawn to the special limitations to use which must be observed when these products are taken into service to maintain compliance with the above directives. Details of these special measures and limitations to use are available on request, an
9、d are also contained in product manuals. 4 Attention! Cables: This product should only be used with high quality, screened twisted pair audio cables, terminated with metal bodied 3-pin XLR connectors. The cable should be connected to pin 1. Any other cable type or configuration for the audio signals
10、 may result in degraded performance due to electromagnetic interference. Electric Fields: Should this product be used in an electromagnetic field that is amplitude modulated by an audio frequency signal (20Hz to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a freque
11、ncy corresponding to the modulation signal may be experienced under extreme conditions (3V/m, 90% modulation). 5 6 THANK YOU FOR USING THIS KLARK TEKNIK PRODUCT To obtain maximum performance from this precision electronic product, please study these instructions carefully. Installation and operating
12、 the DN3601 is not complicated, but the flexibility provided by its operating features merits familiarisation with its controls and connections. This unit has been prepared to comply with the power requirements that exist in your location. Precautions Before connecting the unit to the mains power, e
13、nsure that the operating voltage is correct for your local supply. Operating voltage is indicated by an adhesive label on the rear panel. Do not install this unit in a location subjected to excessive heat, dust or mechanical vibrations. Power Connection Connection is made by means of an IEC standard
14、 power socket. The unit will operate off any AC voltage between 100 Vac and 240 Vac 50 Hz to 60 Hz. Before connecting this unit to the mains supply, ensure that the fuse fitted is the correct type and rating, as indicated on the rear panel, adjacent to the fuse holder. Safety Warning This unit is fi
15、tted with 3-pin power socket. For safety reasons the earth lead should not be disconnected. If you encounter a problem with earth-loops, remove the ground-lift link located inside the unit to isolate the signal earth from the chassis earth (see Service section for details). This should be carried ou
16、t by a qualified service technician only. To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not remove covers. Dangerous voltages exist inside. Refer servicing to qualified personnel only. 7 After you have unpacked the unit Save all the packin
17、g materials - they will prove valuable should it become necessary to transport or ship this product. Please inspect this unit carefully for any signs of damage incurred during transportation. It has undergone stringent quality control inspection and tests prior to packing and left the factory in per
18、fect condition. If, however, the unit shows any signs of damage, notify the transportation company without delay. Only you, the consignee, may institute a claim against the carrier for damage during transportation. If necessary, contact your supplier or as a last resort, your Klark Teknik importing
19、agent, who will fully co-operate under such circumstances. 8 INTRODUCTION Designed to meet and exceed the needs of the recording, broadcast, installation and live sound industries, the Klark Teknik DN 3601 Programmable Slave Graphic Equaliser is an extremely high quality, digitally controlled, two-c
20、hannel, third-octave equaliser that offers state-of-the-art audio performance in a remote controlable, tamper-proof, cost effective package. The two channels may either be used independently or linked for stereo use. To further extend the flexibility of the equaliser, the unit also incorporates vari
21、able frequency low and high-pass filters, two notch filters with variable frequency and depth and overall gain adjustment on each channel. Being the slave derivative of the Klark Teknik model DN3600, the DN3601 front panel features only twin signal strength meters, clip LEDs, an LED numerical displa
22、y and a power switch. The unit can be controlled by a master DN3600 unit or by a suitably equipped computer or other MIDI control device. Up to 64 DN3601 units (or mixed DN3600s and DN3601s) may be linked in a single MIDI loop via the Pro MIDI Interface on the rear panel. The DN3601 may store up to
23、66 equaliser programs in its own, internal memory and can then take full advantage of the extensive user interface of the controling device. A 16-pin connector is provided on the DN3600 for use in conjunction with the DN60 Real Time Spectrum Analyser enabling room analysis and equalisation to be acc
24、omplished automatically. An extensive equalisation system can be created with central, user friendly control. Slave units may be addressed individually or globally by the master, and will also respond to standard MIDI program change commands. The proprietary analogue filters are based around the Kla
25、rk Teknik “MELT” hybrid filter circuits which offer far greater headroom and dynamic range than is possible using 18-bit linear, digital systems. Benefiting from revised circuitry, these filters are exceptionally reliable and offer greater stability than discrete designs. They are also relatively im
26、mune to electromagnetic interference, unlike coil-based filters. Separate supply rails are used for the digital and analogue circuitry which, in combination with rigorous internal screening, ensures the cleanest possible audio signal path. In order to provide maximum operational flexibility, the sys
27、tem includes a switchable Q mode. The Low Q setting (Q:360) provides an accurate emulation of the industry-standard DN360 equaliser. In High Q mode (Q:27), the performance emulates the DN27. To maintain the optimum signal to noise ratio and headroom at all equaliser settings, the gain control acts o
28、n the equaliser sections themselves rather than being a simple pre or post-equalisation gain stage. Additionally, an Auto gain mode is included in the system which automatically scales the gain of the individual equaliser bands as cut or boost is applied to reduce the risk of accidental clipping and
29、 to maintain a safe working headroom. Both the input and output circuitry is electronically balanced with a nominal operating level of +4dBu. The output circuitry is based on the Midas XL3 output stage, giving exceptionally high drive capability. A transformer option is available for both inputs and
30、 outputs. 9 Installation The inputs and outputs are fully balanced on XLR connectors and are wired conventionally with pin 1 as ground. Because the system is fully floating, either pin 2 or pin 3 can be designated as hot so long as the same protocol is adhered to for both the input and the output co
31、nnectors. The DN3601 is designed for use in both fixed and mobile installations where it can be mounted in a conventional 19 inch rack occupying just 2U of height. In mobile situations where rough handling is a possibility, it is advisable to support the rear of the unit to prevent undue stress bein
32、g placed on the front panel. Ensure that the unit has sufficient ventilation and that it is not placed directly over any device which runs hot such as a power amplifier or console power supply. 10 Instrument Familiarisation Front panel functions NUMERIC WINDOW: Displays the address number of the Sla
33、ve and flashes on and off when the unit is being addressed by an external controler, such as a DN3600. METERS: Separate 10-segment bargraph level meters monitor the signal level in channels A and B over the range -12dB to +15dB. The Clip warning LED monitors seven different points within the circuit
34、ry of the DN3601 and flashes if the level at any point comes within 2dB of clipping. POWER SWITCH: Switches the unit on and off. When the unit is off, there is a hard relay bypass which connects the input signal directly to the output. Rear Panel Functions Balanced Input XLR Sockets Balanced Output
35、XLR Sockets Pro MIDI XLR Connectors: These follow the same wiring convention as conventional MIDI DIN sockets. These are used for performing system exclusive data transfer and for linking multiple units in a master/slave configuration. See service section for wiring convention. Voltage Selector Swit
36、ch: selects between 120V and 240V operation. IEC Mains Socket. 11 MASTER/SLAVE OPERATION The Klark Teknik Pro MIDI Master/Slave system allows up to 65 DN3601 and DN3600 units to be operated, either individually or together, from the front panel of a single DN3600 or a siutably equiped computer. The
37、system is simple to connect, simple to operate and protects itself from the dangers of unreliable power supply and damaged connections. Once programmed, the equaliser program memories resident in the DN3601 Slaves may be selected via ordinary MIDI program change commands without the need for a DN360
38、0 master unit. This provides an economical way of managing a large installation as the slave system is both cost effective and secure from inadvertent tampering. Connections. For remote control of all parameters, any DN3601, DN3600 and computer devices must be linked in a closed loop via their Pro M
39、IDI interfaces - MIDI OUT to MIDI IN. Master/Slave configuration is automatic when two or more DN3600 and/or DN3601 units linked in this way. Remote control is via system exclusive messages. Note: The loop must be closed. Each MIDI OUT must be connected to the next MIDI IN. If MIDI program change me
40、ssages from some other device are to be injected onto the Klark Teknik loop, this must be done via a MIDI MERGE unit. Master SlaveSlave Slaves Optional MIDI Merge 12 Any DN3600 in the loop can be designated as the Master by entering the Slaves sub menu (press Utilities, More., Slaves on the DN3600).
41、 The other DN3601 and DN3600 units in the loop will automatically configure themselves as slaves, with the first being number 1, the second being number 2 and so on. Each slave will display its number on its own front panel LED display. A maximum of 64 units may be connected in this way (65 includin
42、g the Master). To address an individual DN3601 Slave, enter the Slaves sub-menu of the Master DN3600 unit. The slave address number can now be changed using the FREQ or LEVEL rotary controls. Press the Slaves soft key a second time to initiate control of the selected device. All the controls and dis
43、play modes now affect only the selected DN3601 Slave unit. The number of the selected Slave is displayed as highlighted text at the top of the LCD screen. The address number on the front panel LED of the DN3601 will flash on and off. Only the Slaves and Lock sub menus relate to the Master unit. To a
44、ddress another slave, enter the Slaves sub menu and select a new slave number. To address all the Slaves in the loop, enter the Slaves sub menu and select SELECT ALL. All functions and controls now affect all units including the Master. For example, performing an Auto EQ function now will adjust all
45、 the units in the loop to equalise the spectrum of a DN60 connected to the master. To return to normal operation, ie adjustment of the Master itself, the Slaves selection must be returned to “STAND ALONE”. The slave units will retain their current settings until changed. All controls and display mod
46、es now affect only the Master unit. Note: A MIDI loop can only have one Master. Initiation of another master by entering its Slaves menu will cancel the original master and renumber the loop. Program Changes. DN3601 Slaves (and DN3600s) will respond to standard MIDI program change messages without t
47、he need for a DN3600 master unit or a closed loop. Just feed the MIDI signals into the MIDI IN socket. All MIDI messages will be copied through to the MIDI OUT socket. A system such as this offers benefits of reduced cost and inherent tamper proof security. As well as real time operation from a cent
48、ral control position, a network of equalisers may be loaded with the memories necessary for various tasks and then, with the master unit removed, will respond only to program changes. 13 DETAILS OF OPERATION Being a description of the features and functions accessible via a DN3600 master unit with v
49、ersion 2.0 software. Initial, Default Display Soft key options: More EQ A : B : Link Utilities Bypass Fader adjustment The Virtual Graphic Equaliser faders are selected either by pressing the appropriate frequency key or by rotation of the FREQ rotary control. There are several ways to select a range of adjacent faders. 1.Hold a single Frequency key until it starts to flash. This sets one end of the range. Define the other end of the range by pressing a second Frequency key, or by