《ramsa_wrda7 电路图.pdf》由会员分享,可在线阅读,更多相关《ramsa_wrda7 电路图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、Users Guide Upgrade Utility for Audio Mixer WR-DA7 Version 2.0 The meter bridge shown in photo is one of the optional accessories. Before attempting to connect or operate this product, please read these instructions completely. Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 TRAD
2、EMARKS All trademarks are the property of their respective copyright holder for use in this document, including but not limited to; ProTools is a registered trademark of DigiDesign ADAT is a registered trademark of ALESIS Corp. CS-10 is a registered trade mark of JL Cooper Electronics Macintosh is a
3、 registered trademark of Apple Computer, Inc. Windows is either a trademark or a registered trademark of Microsoft Corporation Copyright 2000 Limit of Liability/Disclaimer of Warranty: The author, Audio Video Systems Division of Matsushita Communication Industrial Co., LTD and Professional Audio Div
4、ision of Panasonic Broadcast and Digital Systems Company have used their best efforts in preparing this book. However, Audio/Video Systems Division of Matsushita Communication Industrial Co., LTD and Professional Audio Division of Panasonic Broadcast and Digital Systems Company make no representatio
5、n or warranties with respect to the accuracy or completeness of the contents of this book and hereby specifically disclaims any implied warranties or merchantability or fitness for any particular purpose and shall in no event be liable for any loss of profit or any other commercial damage, including
6、 but not limited to special, incidental, consequential, or other damages. 2 Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 Panasonic DA7 Upgrade Utility License Agreement Matsushita Communication Industrial Co., Ltd. (“MCI”) permits you to use the Panasonic DA7 Upgrade Utility s
7、oftware (“Software”) on condition of your acceptance of the following terms. As use of the Software shall be deemed that you have accepted the following terms, please read the following terms carefully before you use the Software. 1. Copyright and License for use MCI grants you an individual and a n
8、on-exclusive right to use the Software on only single computer. You own the magnetic media on which the Software is originally or subsequently recorded or fixed, but MCI retains title to and ownership in the Software. The Software and the accompanying documentation are copyrighted by MCI. 2. Prohibi
9、tion and Restrictions You may not modify, adapt, translate, decompile, disassemble, reverse-engineer, or create derivative works based on the Software, nor may you allow another person to do so. The Software may not be duplicated, corrected, modified, lent, leased, sold, distributed, licensed or dis
10、posed of in any other way in part or in whole. The Software may not be transmitted over a network to another computer without written authorization from MCI. You may transfer the Software and accompanying documentation on a permanent basis to transferee provided it is for non-commercial purposes and
11、 you retain no copies and recipient agrees to the terms of this Agreement. 3. Limited Responsibility MCI shall not be liable for any direct, indirect, consequential, or incidental damages (including damages from but not limited to data loss, loss of business profit, business interruption, or loss of
12、 business information) arising out of the use of or inability to use the Software even, if MCI has been advised of the possibility of such damages. 3 Downloaded from www.M manuals search engine RadioFans.CN 收音机爱 好者资料库 4 (This page left blank intentionally.) Downloaded from www.M manuals search engin
13、e 5 The DA7 Upgrade Utility Users Guide Introduction Welcome to New Version 2.0 Operating System for the DA7. We hope you are enjoying your DA7, and that you will find that the 64 enhancements we have included in the Version 2.0 operating system will increase your enjoyment of our product. Please no
14、te that there are changes in the default settings of the DA7, some of which will affect how you operate your mixer. Please take a few moments to review the changes. This document covers ALL upgraded features to the original DA7 Operating System (Version 1.01/1.02). Therefore, we strongly recommend t
15、hat you review this document before you upgrade your console so that you are familiar with all the new features. We also recommend that you print and keep this document as a supplement to the DA7 operation manual that came with your DA7. If you would like to have an electronic copy of the DA7 user g
16、uide, it can be downloaded from Once you have entered this site, go to the download section and select DA7 User Guide. Downloaded from www.M manuals search engine 6 Important Notes: Due to the fact that there are many new default settings in the Version 2.0 upgrade, we are recommending that you do a
17、 Master Reset of the console after the upgrade. Therefore you should backup any settings in the Libraries, Scene Memories, Mixes, etc. BEFORE you begin the upgrade process. Instruction for this process can be found in Section 1. After the upgrade, make certain that you look at the MIDI REMOTE and IN
18、PUT MTX windows on the LCD to see if they are properly assigned. If they are not, please reset them to your desired settings or, do a master reset to the console to return the DA7 to the new factory default settings. There are several updates to the default settings that may have an affect on the se
19、ttings in your console. This will protect you from accidental erasure of any of your presets. After the upgrade, simply restore the data you have saved following the instructions in Section 1. If you are planning to use our optional automation software package (MAX), please be aware that you must be
20、 running at least O.S. Version 1.10 for it to operate properly, and we recommend that you upgrade your DA7 to Version 2.0 for optimum performance. Some of the features documented here are from intermediate upgrade versions. If you are upgrading your console from Version 1.01 or 1.02, all of the feat
21、ures in this document will apply to you. If you have previously upgraded your console to Version 1.10-1.20-1.21 or 1.22, you have already been using some of the features documented here in Section 2. If you are upgrading from version 1.21 or 1.22, you should follow all the instructions in Section 1,
22、 and then you may proceed directly to Section 3. Contents: Section 1 - Upgrade Utility instructions Section 2 - Upgrade from Version 1.01/1.02/1.10/1.20 Section 3 - Upgrade from Version 1.21 or 1.22 Section 4 - APPENDIX - New Default Settings Downloaded from www.M manuals search engine 1-1 Section 1
23、 Upgrade Utility Instructions Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Cables and Connections. . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Setting up
24、the DA7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Operating the DA7 Upgrade Utility. . . . . . . . . . . . . . . . . 1-7 SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 BACKUP
25、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 UPGRADE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 RESTORE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 EXIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
26、8 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 Downloaded from www.M manuals search engine 1-2 Preface The DA7 Upgrade Utility is a multifunction software manager program specifically designed to allow you to perform operating system upgrades, as well as backup a
27、nd restore functions for the library, scene memory, automation data, as well as setup data for the DA7. Using the serial ports on the DA7 and your computer, data can be sent to or from a DA7 and then saved to your computer hard disk for backup and retrieval. The memories and programs can be retrieve
28、d individually, or in groups. The retrieved memory and program titles can be edited using the computers keyboard. The data, including edited titles, can be transmitted between the computer and the DA7. Installation It is recommended that you perform a backup of your current data BEFORE you perform a
29、n upgrade to your DA7s operating system. Macintosh Version 1. Copy the files for installation file (DA7UPINS) to a folder on to your hard drive. 2. Once you have loaded the file, you need to open the folder to gain access to the following files: DA7UPG - Executable file of the Upgrade Utility V200R2
30、3.mot - Upgrade file for the DA7 CNV - Data Conversion folder for old backup versions BKUP - Backup Data folder 3. Open the file “DA7UPG”. 4. Test the communication path between the computer and your DA7 by clicking on the VERSION button on your computer in the open window. If it is properly connect
31、ed, you will see the version of software that is currently in your DA7 displayed, and the “BACKUP” and “RESTORE” buttons will become active. (You need to set up DA7 and Upgrade Utility Configuration before test. To set up Configuration, read the following chapter “Cables and Connections”, “Setting u
32、p the DA7”, and “Setup” in “Operating the DA7 Upgrade Utility”.) Downloaded from www.M manuals search engine 1-3 Windows Version 1. Copy the files for installation file (DA7UPINS.EXE) to folder on to your hard drive. 2. Doubleclick on “DA7IPINS.exe”, If you are unzipping the file, you can unzip it.
33、The installation file installs the upgrade utility in “C:UpgradeDA7”. 3. Once you have loaded the file, you need to open the folder to gain access to the following files: DA7UPG.exe - Executable file of the Upgrade Utility V200R23.mot - Upgrade file for the DA7 CNV - Data Conversion folder for old b
34、ackup versions BKUP - Backup Data folder 4. Click on DA7UPG.exe to open the utility. 5. Test the communication path between the computer and your DA7 by clicking on the VERSION button on your computer in the open window. If it is properly connected, you will see the version of software that is curre
35、ntly in your DA7 displayed, and the BACKUP and RESTORE buttons will become active. (You need to set up DA7 and Upgrade Utility Configuration before test. To set up Configuration, read the following chapter “Cables and Connections”, “Setting up the DA7”, and “Setup” in “Operating the DA7 Upgrade Util
36、ity”.) Downloaded from www.M manuals search engine 1-4 Cables and Connections For Macintosh Computer Use ONLY the recommended serial cable (cross cable) with a wiring pattern as described below. This cable is the same cable used for the ImageWriter II printer. Do NOT use a standard Macintosh Serial
37、cable. Use this to connect between the modem port or printer port of the computer and the TO PC port of the DA7. For Windows/95 or PC compatible computer Use ONLY a serial cable with a wiring pattern as described below. This cable is available from Panasonic Pro Audio in the United States, part numb
38、er DA/DB-DIN. Do NOT use a standard serial cable. Use this cable to connect between the serial port (COM1, COM2, COM3 or COM4) of your PC and the TO PC port of the DA7. When using a Windows computer, use the following cable: Pinout configuration of the cable. When building this cable, connect the pi
39、ns in the following manner: DA7 port (Mini DIN 8p) pin #PC port (D-sub 9p) pin # 1 . . . . . .8 2 . . . . . .7 3 . . . . . .2 4 . . . . . .5 5 . . . . . .3 7 8 3 5 2 1 2 3 4 5 Pin #Pin # 1 2 3 4 5 6 7 8 Frame 1 2 3 4 5 6 7 8 Frame Shield wire Pin #Pin # Mini DIN 8 (Male)DB9 (Female) Windows Computer
40、 TO PC of the DA7 Mini DIN 8 (Male) Mini DIN 8 (Male) TO PC of the DA7 MODEM or Printer port of Mac Computer Downloaded from www.M manuals search engine 1-5 Setting up the DA7 Set up the DA7 for transmitting and receiving data with your PC. 1. Select the MIDI button in the SETUP section on the TopPa
41、nel of the DA7 to display the MIDISETUP Window of the LCD display. This is so you can set up the transmit and receive data parameters. 2. Select TO PC in the PORT SELECT area in the SERIAL I/O SETUP area. 3. Cursor to BAUD RATE within the SERIAL I/O SETUP area of the MIDISETUP window. Use the parame
42、ter dial to select 38.4K. 4. Cursor to PORT, and select TO PC in both the Gen RX and Gen TX fields in MIDISETUP window. 5. Cursor to the CH area. Be sure to select the same MIDI CH numbers that are used on the Upgrade Utilitys SET UP window in the Gen RX and Gen TX fields. Remember that all MIDI cha
43、nnel #s must be the same. 6. Cursor to the SYSTEM EX field. Select TX and press ENTER. Select RX and press ENTER. MIDI SETUP Window Downloaded from www.M manuals search engine 1-6 7. Select the MIDI button so as to display the MIDI BULK window on the LCD display. Cursor to the RX field. Select RX an
44、d press ENTER. The RX field appears in inverse video. MIDI BULK Window Downloaded from www.M manuals search engine 1-7 Operating the DA7 Upgrade Utility Menu window Start by displaying the Menu window -DA7 Upgrade Utility -on your computer. Select the function that you want to perform by pressing: S
45、et Up, Version, Backup, Upgrade, Restore or Exit. SetupThis button accesses the Setup window. This is where you select the Serial Ports and the MIDI Channels to be used for transmitting and receiving data with the DA7. VersionThis button accesses the information about the software version that curre
46、ntly resides within your DA7. BackupThis button accesses the area where you begin the process of backing up the data from the DA7, and where you select the types of data (such as Mixes, Scene Memories, etc) to be backed up. UpgradeThis button accesses the area where you begin the process of upgradin
47、g the software in the DA7 (An upgrade takes approximately 20 minutes). The upgrade procedure begins by restarting the DA7. You will then receive messages that display both on the computer monitor and the LCD panel of the DA7 with instructions for upgrading the console. RestoreThis button accesses th
48、e area where you begin the process of restoring the user data that was saved in the backup operation. ExitThis button closes the DA7s Upgrade Utility. Downloaded from www.M manuals search engine 1-8 SETUP Clicking on the Setup button displays the Setup window. This is where you select the Serial Por
49、ts and the MIDI Channels to be used for transmitting and receiving data with the DA7. Selecting the serial port For Macintosh: Select either the Modem Port or Printer Port For Windows/95: Select from COM1, COM2, COM3 or COM4 Port Selecting the MIDI channels (for transmitting and receiving) Any MIDI Channel 1 through 16 can be selected for Receiving and Transmitting data. Once you have selected a channel in the upgrade utility window, you must also check that it is selected to the same channel that has been set in the Gen RX and Gen TX fields of th