1、1 SoundcraftSoundcraft D DPSPS-3 3 P Powerower S Supplyupply USER GUIDE and TECHNICAL MANUAL RadioFans.CN 收音机爱 好者资料库 2 Harman International Industries Ltd. 2004 All rights reserved Parts of the design of this product may be protected by worldwide patents. Part No. ZM0317-01 Soundcraft is a trading d
2、ivision of Harman International Industries Ltd. Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor. Soundcraft shall not be liable for loss or dam- age whatsoever arising from the use of information or any error contained in t
3、his manual. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, electrical, mechanical, optical, chemical, including photocopying and recording, for any purpose without the express written permission of Soundcraft. Harman I
4、nternational Industries Limited. Cranborne House, Cranborne Road, Potters Bar, Hertfordshire, EN6 3JN UK. Tel: +44 (0) 1707 665000 Fax: +44 (0) 1707 660742 Email: IMPORTANT Please read this manual carefully before connecting your DPS-3 Power Supply Unit to the mains for the first time. Part No. ZM03
5、17-02 RadioFans.CN 收音机爱 好者资料库 3 Contents Safety Symbol Guide.4 Important Safety Instructions .5 Fitting The Feet Or Rackmounting .7 Connecting Up.8 Pin-outs Of DC Output Connector .8 Circuit Diagram .9 PCB Layout.10 Parts List.11 Dimensions .14 Warranty.15 RadioFans.CN 收音机爱 好者资料库 4 CAUTIONS Must be
6、followed carefully to avoid bodily injury. WARNINGS Must be observed to avoid damage to your equipment. NOTES Contains important information and useful tips on the operation of your equipment. SAFETYSAFETY S SYMBOLYMBOL G GUIDEUIDE For your own safety and to avoid invalidation of the warranty all te
7、xt marked with these Symbols should be read carefully. 5 IMPORTANTIMPORTANT S SAFETYAFETY I INSTRUCTIONSNSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventil
8、ation openings. Ventilation should not be impeded by covering the ventilation openings with items such as newspapers, table cloths, curtains etc. Install in accordance with the manufacturers instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other appara
9、tus (including amplifiers) that produce heat. Do not defeat the safety purpose of a polarised or grounding type plug. A polarised plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for yo
10、ur safety. If the provided plug does not fit into your outlet, consult an electri- cian for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs, conve- nience receptacles and the point where they exit from the apparatus. Only use attachment
11、s/accessories specified by the manufacturer. Use only with the cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. Unplug this apparatus during ligh
12、tning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. It is recommended that all mainte- nance and service on the product should be carried out by Soundcraft or its autho- rised agents. Soundcraft cannot accept any liability whatsoever for any loss
13、 or damage caused by service, maintenance or repair by unauthorised personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects fallen into the apparatus, the apparatus has been exposed to rain or m
14、oisture, does not operate normally, or has been dropped. No naked flame sources, such as lighted candles, should be placed on the apparatus. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Do not expose the apparatus to dripping or splashing a
15、nd do not place objects filled with liquids, such as vases, on the apparatus. 6 THIS APPARATUS MUST BE EARTHED. Under no circumstances should the safety earth be disconnected from the mains lead. The mains supply disconnect device is the mains plug. It must remain accessible so as to be readily oper
16、able when the apparatus is in use. If any part of the mains cord set is damaged, the complete cord set should be replaced. The following information is for reference only. The wires in the mains lead are coloured in accordance with the following code: Earth (Ground):Green and Yellow (US - Green/Yell
17、ow) Neutral:Blue (US - White) Live (Hot):Brown (US - Black) As the colours of the wires in the mains lead may not correspond with the coloured mark- ings identifying the terminals in your plug, proceed as follows: The wire which is coloured Green and Yellow must be connected to the terminal in the p
18、lug which is marked with the letter E or by the earth symbol. The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L Ensure that t
19、hese colour codes are followed carefully in the event of the plug being changed This unit is capable of operating over a range of mains voltages as marked on the rear panel. It is important to ensure that the correct mains fuse is fitted before switching on the unit. 7 FITTINGFITTING T THEHE F FEETE
20、ET O OR R R RACKMOUNTINGACKMOUNTING 8 CONNECTINGCONNECTING U UP P Before you start Ensure the DPS-3 power supply is NOT connected to the Mains and is turned OFF. The Power supply can be positioned anywhere within reach of the console and an available power socket, but is best rack- mounted in a posi
21、tion where airflow through the vents is not obstructed and where the power switch or cables cannot be accidentally knocked. Connect the multi-way power cable between the DPS-3 External Power Supply and the consoles con- nector. Screw the connector locking ring clockwise on both units to secure the c
22、able. The locking ring should be firm, but not tight. Connect an IEC type mains cable with the plug fused at 3 AMPS, to the mains input socket on the DPS-3. Connect the other end to the nearest plug socket and switch on the power to the DPS-3. PINPIN-O OUTSUTS O OF F D DC C O OUTPUTUTPUT C CONNECTOR
23、ONNECTOR 9 Circuit Diagram 10 PCB Layout 11 PARTS LIST GB4 PSU ASSYR0050A-04-AF IdentDescriptionPart Number GB4 PCB PSU BOARDS0050A-04 HEATSINK THERMALOY 7121D XV05-PN10004 POWER STN MIXER PSU HEATSINKPN1240 DRIVER MOUNTING CLIPZC0231 (Safety Critical Part)! FUSE 5X20MM T 2A 250VZD8002 BR1BDG RECT K
24、BU6K SIL 6A 800VBC0222 C1CAP ELEC VERT 1000UF 25V ESR 1CE0512 C2CAP ELEC VERT 1000UF 25V ESR 1CE0512 C3CAP ELEC VERT 1000UF 25V ESR 1CE0512 C4CAP ELEC VERT 1000UF 25V ESR 1CE0512 C5CAP ELEC VERT 1000UF 25V ESR 1CE0512 C6CAP CER 1NF 1KV 5MM PITCHCA0055 C7CAP CER 1NF 1KV 5MM PITCHCA0055 C8CAP CER 1NF
25、1KV 5MM PITCHCA0055 C9CAP ELEC VERT 100UF 100VCE10046 C10CAP CER 220PF 1KV DISC CA-CPCA10018 C11CAP CER 220PF 1KV DISC CA-CPCA10018 C12CAP CER ML 0.1UF 50V 5MMCA0026 C13CAP CER ML 0.1UF 50V 5MMCA0026 C14CAP CER ML 0.1UF 50V 5MMCA0026 C15CAP CER ML 0.1UF 50V 5MMCA0026 C16CAP ELEC VERT 47UF 63V SKP 0.
26、2CE0402 C17CAP ELEC VERT 47UF 63V WGP ESRCE0466 C19MICRO-BOX 5MM 5% 100V 220NCC0251 C20CAP ELEC VERT 100UF 100VCE10046 C21CAP 100N 250V POLY DIP 10MMCC10026 C22CAP ELEC 10UF 100V VERT 105DEGCE0535 C23CAP ELEC 330UF 25V VERT 105DEGCE0536 C24(Safety Critical Part)! CAP CER 4N7 250V Y1 RATEDCC10088 C29
27、MICRO-BOX 5MM 5% 63V 1NCC0238 C30CAP CER ML 1000PF 100V 5% 5MMCA0015 C34CAP ELEC RAD 560UF 400V 35X35CE10049 C37CAP ELEC VERT 1UF 63V SSP 4D 7CE0485 C38CAP CER ML 0.1UF 50V 5MMCA0026 C40CAP CER 150PF 100V TPD 0.2CA0045R C41(Safety Critical Part)! CAP 1UF 275VAC RFI CLASS X2CX10000 C44MICRO-BOX 5MM 5
28、% 470NF 63/100VCC0267 C45CAP ELEC VERT 1UF 63V SSP 4D 7CE0485 C46MICRO-BOX 5MM 5% 63V 2N2CC0240 C51CAP CER ML 0.1UF 50V 5MMCA0026 CN1(Safety Critical Part)! IEC FILTER 3A PCB MTG.FJ8046 CN220WY G80 VERT ML HDR LATCHFA0085 D1RECTIFIER MUR1640CT TO-220BC10003 D2RECTIFIER MUR1640CT TO-220BC10003 D3RECT
29、IFIER MUR1640CT TO-220BC10003 D4DIODE RECTIFIER 8ETX06 600V 8ABC0226 D5DIODE FAST TYPE EGP10G 400V 1ABA10014 D6DIODE SF1600 1A FAST SOD-57BA10008 D7DIODE 1N5402 200V 3A PRFMD .6BA0009 D8DIODE RECTIFIER 8ETX06 600V 8ABC0226 D10DIODE FAST TYPE EGP10G 400V 1ABA10014 12 D11DIODE FAST TYPE EGP10G 400V 1A
30、BA10014 D14TL431 SHUNT REGULATOR TO92BE0503 F1(Safety Critical Part)! FUSE HOLDER 6.3A PCB MTGZD8023 IC3VOLTAGE MODE PWM DIP-14BE10032 L1INDUCTOR-OUTPUT -GB4/RENOP0009-01 L2FERRITE BEAD AX 5X3.5MM TAPEDHC0021 L4INDUCTOR 10UH TOKO A823LY-100KHC0028 L5INDUCTOR 10UH TOKO A823LY-100KHC0028 L6INDUCTOR 10
31、UH TOKO A823LY-100KHC0028 L8DIGI 328 LINE FILTER CHOKEHC0037 OPT1(Safety Critical Part)! OPTO TRANSISTR H11AV1AVMBD0396 R1MF 1W RES 5% 4R7 PRO1AE0047 R2MF 1W RES 5% 4R7 PRO1AE0047 R3MF 1W RES 5% 4R7 PRO1AE0047 R4MF 1W RES 5% 4R7 PRO1AE0047 R5MF 1W RES 5% 4R7 PRO1AE0047 R6AP 0.25W RES 1% 1K BLAP1349
32、R7AP 0.25W RES 1% 1K BLAP1349 R8RES 22K 5% 5W WW TYP.SQM5AG10015 R9RES 22K 5% 5W WW TYP.SQM5AG10015 R10AP 0.25W RES 1% 1K BLAP1349 R11RES 4K7 5% 1W MF PRO1AE10021 R12AP 0.25W RES 1% 1K BLAP1349 R13AP 0.25W RES 1% 1K BLAP1349 R14MF 0.25W RES 1% 20K BLAP1380 R15RES 0R47 5% 2W MF PF02AE10036 R22RES 0R4
33、7 5% 2W MF PF02AE10036 R24MF 2W RES 5% 150K PRO2AE2154 R28MF 1W RES 5% 10R PRO1AE0100 R29MF 0.25W RES 1% 3K6 BLAP1362 R30MF 1W RES 5% 10R PRO1AE0100 R31RES 4K7 5% 1W MF PRO1AE10021 R32MF 0.25W RES 1% 680K BLAP1417 R33MF 0.25W RES 1% 1M BLAP1421 R34AP 0.25W RES 1% 1K BLAP1349 R35MF 0.25W RES 1% 470K
34、BLAP1413 R36MF 0.25W RES 1% 10K BLAP1373 R39MF 0.25W RES 1% 22K BLAP1381 R40AP 0.25W RES 1% 1K BLAP1349 R44MF 0.25W RES 1% 12K BLAP1375 R46AP 0.25W RES 1% 1K BLAP1349 R47AP 0.25W RES 1% 1K BLAP1349 R48MF 0.25W RES 1% 6K8 BLAP1369 R49MF 0.25W RES 1% 220R BLAP1333 R52MF 0.25W RES 1% 1K1 BLAP1350 R53MF
35、 0.25W RES 1% 10K BLAP1373 SP1SPADE TAB VERT PC 0.125CFF10022 SP2SPADE TAB VERT PC 0.125CFF10022 SP3SPADE TAB VERT PC 0.125CFF10022 SP4SPADE TAB VERT PC 0.125CFF10022 SP51/4 PC MNTNG BLADE VERTFF0676 SP61/4 PC MNTNG BLADE VERTFF0676 SP71/4 PC MNTNG BLADE VERTFF0676 SP81/4 PC MNTNG BLADE VERTFF0676 S
36、P91/4 PC MNTNG BLADE VERTFF0676 SP101/4 PC MNTNG BLADE VERTFF0676 SP111/4 PC MNTNG BLADE VERTFF0676 SP121/4 PC MNTNG BLADE VERTFF0676 13 SP13SPADE TAB VERT PC 0.125CFF10022 SP14SPADE TAB VERT PC 0.125CFF10022 SP15SPADE TAB VERT PC 0.125CFF10022 SP16SPADE TAB VERT PC 0.125CFF10022 SW1(Safety Critical
37、 Part)! PANASONIC DPST HOR MAINS SWTDJ8002 TX1TRANSFORMER SMPS.GB4/RENOP0008-01 TH1(Safety Critical Part)! THERMISTER 3A INRUSH LIMITERAZ2279 TR1TRANS TIP122 TO220 XE01-BD10026 TR2MOSFET PWR.STP13NK60Z/FPBD10051 TR4TRANS TIP122 TO220 XE01-BD10026 ZD1ZENER DIODE 1.3W 51VBB0131 ZD3ZENER DIODE 250MW 13
38、VBB10025 DPS3 LED PCB ASSY. AFR0105A-01-AF IdentDescriptionPart Number LED1LED 3MM ULTRA RED ROUNDJA10025 R1SM0805 RES 2K4 1% 0.1W T200AS0242R-0805F DPS3 SRC PCB ASSY AFR0099A-02-AF IdentDescriptionPart Number PCB DPS3 SRC BOARDS0099-02 C1CAP CER 100NF 10% 50V X7RCS7104R-0805K C2CAP CER 100NF 10% 50
39、V X7RCS7104R-0805K C3CAP CER 100NF 10% 50V X7RCS7104R-0805K C4CAP CER 100NF 10% 50V X7RCS7104R-0805K C5CAP CER 100NF 10% 50V X7RCS7104R-0805K C6CAP CER 15NF 10% 100VCS7153R-0805K1 14 DIMENSIONSDIMENSIONS 15 WARRANTYWARRANTY 1Soundcraft is a trading division of Harman International Industries Ltd . E
40、nd User means the person who first puts the equipment into regular operation. Dealer means the person other than Soundcraft (if any) from whom the End User purchased the Equipment, provided such a person is authorised for this purpose by Soundcraft or its accredited Distributor. Equipment means the
41、equipment supplied with this manual. 2If within the period of twelve months from the date of delivery of the Equipment to the End User it shall prove defective by reason only of faulty materials and/or workmanship to such an extent that the effectiveness and/or usability thereof is materially affect
42、ed the Equipment or the defec- tive component should be returned to the Dealer or to Soundcraft and subject to the following conditions the Dealer or Soundcraft will repair or replace the defective components. Any components replaced will become the property of Soundcraft. 3Any Equipment or componen
43、t returned will be at the risk of the End User whilst in transit (both to and from the Dealer or Soundcraft) and postage must be prepaid. 4This warranty shall only be valid if: a) the Equipment has been properly installed in accordance with instruc- tions contained in Soundcrafts manual; and b) the
44、End User has notified Soundcraft or the Dealer within 14 days of the defect appearing; and c) no persons other than authorised representatives of Soundcraft or the Dealer have effected any replacement of parts maintenance adjustments or repairs to the Equipment; and d) the End User has used the Equi
45、pment only for such purposes as Soundcraft recommends, with only such operating supplies as meet Soundcrafts specifications and otherwise in all respects in accordance Soundcrafts recommendations. 5Defects arising as a result of the following are not covered by this Warranty: faulty or negligent han
46、dling, chemical or electro-chemical or electrical influences, accidental damage, Acts of God, neglect, deficiency in electrical power, air-conditioning or humidity control. 6The benefit of this Warranty may not be assigned by the End User. 7End Users who are consumers should note their rights under this Warranty are in addition to and do not affect any other right