1、BOGEN A LEAR SIEGLER COMPANY MCP35 MASTER CONTROL PANEL PI-35/SI-35 SYSTEMS INSTALLATION AND SERVICE MANUAL IT IS RECOMMENDED THAT THIS ENTIRE MANUAL BE CAREFULLY READ BEFORE ATTEMPTING TO INSTALL THE MASTER CONTROL PANEL OR ANY OF THE SYSTEMS COVERED HEREIN. PI-35 TABLE OF CONTENTS SECTION ONE: MCP

2、35 MASTER CONTROL PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TECHNICAL SPECIFICATIONS. DESCRIPTION. INSTALLATION. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power and Grounding. Auxiliary Power. Line-Matching Transformers. Input Connections. O

3、utput Connections. ADJUSTMENTS AND MODIFICATIONS. Gain Adjustments. Defeating MIC 1 to CONSOLE MIC Configuration ASSOCIATED EQUIPMENT. Time Tone/Telco Page. External Booster Amplifier. SCHEMATIC DIAGRAMS. MCP35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SBA225. . . . . . .

4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 . 2 .4 . 4 .4 . 4 .4 4 . 4 . 5 5 . 5 . 5 . 5 . 5 6 7 SECTION TWO: Multi-Graphic PI-35 SYSTEM/ SI-35 SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TECHNICAL SPECIFICATIONS DESCRIPTION . . . . . . . . . . . . . .

5、 ASSOCIATED EQUIPMENT . . . . Switchbanks. Switchbank Modules. . . . . . . . . . . . . SCR25 Call-In Module . . . . . . . . TZMA Time Zone Module . . . Staff Station Equipment . . . . . Call/Emergency Switches . . . . APPENDIX. GENERAL WIRING. STATION WIRING. CONTROL CENTER WIRING. MAINTENANCE. Boge

6、n Service. Replacing Components. Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . 8 . . 8 . . . 8 . . . 9 . . 9 . . 9 . . 9 . . . 9 . .a-l . . .a-l . . .a-l . .a-l . .a-l . .a-l . . .a-3 . . .a-3 1986 Lear Siegler Inc. Pri

7、nted in U.S.A.8610 54-5830-01 RadioFans.CN 收音机爱 好者资料库 SECTION ONE: MCP35 Rated Output: Frequency Response: Distortion: Inputs: output: Input Sensitivity (for rated output): Power Requirements (120VAC, 6OHz): Dimensions: Weight: Controls Hi-Z unbalanced AUX input; Hi-Z booster input Balanced 25VCT li

8、ne Microphone-300 V Auxiliary- 1 OOmV 1OOW maximum 19”W x 3-1/2”H x 10”D (48.2 x 8.9 x 25.4cm) Approximately 10 lbs. (4.8 kg) Input Selector Pushbuttons-MIC 1, MIC 2, AUX Level Controls-MONITOR/LISTEN, PROGRAM (Front Panel) Gain: AUX, MIC 1, MIC 2, LISTEN, TALK, EMERGENCY PAGE (Rear Panel, screwdriv

9、er-adjustable) Distribution Switches-ALL ROOMS, EMERGENCY PAGE Indicators-LED LEVEL Indicators Bogen Sand with color-coded guides for PROGRAM, INTERCOM, and EMERGENCY PAGE DESCRIPTION Bogen Model MCP35 Master Control Panel provides facilities for instantaneous two-way communication and distribution

10、of paging, background music, or other program material for up to 75 speaker-equipped stations. A built-in 8-watt intercom ampli- fier features a frequency response shaped for maximum intel- ligibility. A separate 35-watt program amplifier ensures that program material and/or emergency announcements

11、are clear- ly heard and easily understood. The front panel features step- by-step instructions and color-coded indicia which permit even first-time users to easily operate the system: the intercom chan- nel guide indicia color-code is green, the program channel guide indicia color-code is amber, and

12、 the emergency page guide in- dicia color-code is red. Input facilities are provided for external microphones, tuner, cassette player, or other background music source. Level con- trols and audible and visual monitoring of program material are provided. Distribution is accomplished by simple pushbut

13、- ton program selection and by following color-coded indicia. Emergency announcements to all locations take precedence over program distribution and are accomplished with a single pushbutton selection. Provision is included for time signalling, telephone paging, and for connection to a booster ampli

14、fier. The MCP35 Master Control Panel is used in conjunction with Bogen Room Selector and Annunciator Panels to direct inter- com, or program, to selected staff stations. Replies are heard through the front panel speaker of the MCP35. Calls from staff locations are initiated through the use of call-i

15、n switches and are announced by light and tone annunciation. Provision for voice call-in is included. Model MCP35 control panel permits the user to: . . . . 2 establish direct two-way voice communication between the control panel and any speaker-equipped location via a switchbank and the press-to-ta

16、lk/release-to-listen pushbut- ton, while maintaining simultaneous distribution of pro- gram material to any other speaker-equipped location. disseminate voice announcements to any individual, group, or all speaker-equipped locations. disseminate program material to any individual, group, or all spea

17、ker-equipped locations. easily make program source selection by pressing the appro- priately labelled pushbutton corresponding to input from RadioFans.CN 收音机爱 好者资料库 INSTALLATION LINE-MATCHING TRANSFORMERS NOTE Refer to Appendix for wiring information. UNPACKING Your unit was carefully checked before

18、 leaving the factory; in- spect the shipping container and the unit closely for improper handling. If the unit has been damaged, make an immediate claim to the distributor from whom it was purchased. If the unit was shipped directly to you, save all shipping material, notify the carrier immediately

19、and place your claim. POWER AND GROUNDING The MCP35 Master Control Panel operates from a 12OVAC, 60Hz source and consumes no more than 100 watts. An AC line cord, terminated in a three-prong plug, is provided. The line cord should be plugged into a three-wire grounded outlet pro- viding a nominal 12

20、OVAC, 6OHz power source. It is important to ground the unit; therefore, if a three-wire outlet is not available, an adapter such as Leviton No. 5017 should be used to convert a standard two-wire outlet for use with three-wire plugs. The adapter is provided with a grounding pigtail which should be co

21、nnected to the screw holding the wall plate to the receptacle. In some areas, the wall plate screw is not grounded. In this case it is necessary to connect a grounding wire from the EARTH GND terminal on the rear chassis of the MCP35 to a water or steam pipe. AUXILIARY POWER An 840-watt, three-wire

22、grounded outlet is provided on the rear panel to supply power to accessory equipment. Auxiliary equipment connected to this outlet will be grounded, provided the Master Control Panel line cord has been properly grounded. 8 OHMS I SECONDARY L-J 25 VOLTS PRIMARY COM 4 2 I 1 7 2 $, WATTS The MCP35 Mast

23、er Control Panel is designed for 25-volt con- stant voltage distribution systems. All system loudspeakers must be provided with line-matching transformers. CAUTION Speakers and transformers must be properly matched with respect to power requirements. INPUT CONNECTIONS MICROPHONE INPUTS-terminal stri

24、ps on the rear of the MCP35 provide for two low-impedance balanced or unbalanc- ed microphone inputs. Two-conductor shielded microphone cable should be used. TUNER/PHONO/TAPE INPUTS-two AUX jacks accept single-conductor shielded cable. TAPE RECORDER/BOOSTER AMP INPUT-accepts a two-conductor shielded

25、 cable. INTERCOM CALL-IN LINE-connect parallel lines from station call-in switches with two-conductor shielded cable. SWITCHBANK CONNECTION-nine-pin plug connects three pairs plus three control wires from a switchbank. TIME CLOCK INPUT-terminal strip provides single-circuit time capability. TELCO PA

26、GE INPUT-jack accepts telephone paging input from Bogen Model WMT-1 accessory transformer. OUTPUT CONNECTIONS A 25VCT external booster output is provided. Figure 2-Model T725, Line-Matching Transformer Figure 3-Model MCP35, Rear Panel 4 ADJUSTMENTS AND MODIFICATIONS GAIN ADJUSTMENTS (For Qualified S

27、ervice Personnel Only) Gain adjustments are made with a screwdriver at the rear chassis; set the INPUT GAIN controls so that signal clipping cannot occur. Proceed as follows: 1. Apply input(s) to the desired channel(s). 2. Set the corresponding front panel control(s) to maximum. 3. Adjust each appro

28、priate INPUT GAIN control (looking at rear panel, turn clockwise to increase or counterclockwise to decrease gain) so that the red “0” (overload) LED lights; then, turn counterclockwise only until the LED is extinguished. MODIFICATIONS Defeating MIC 1 to CONSOLE MIC configuration: Locate and loosen

29、the two screws securing the jumper link on the rear chassis terminal strip connecting the MIC 1 HI terminal to the CONSOLE MIC terminal. (Refer to Figure 3-Rear Panel illustration.) Move the link down, away from the MIC 1 HI terminal. Tighten the screw securing the link to the CONSOLE MIC terminal.

30、4. Remove the l-ohm resistor (or, on some printed circuit boards, the wire jumper) behind the “S38” designation on the pc board. ASSOCIATED EQUIPMENT TIME TONE/TELCO PAGE A time tone can be put through all speakers when the CLOCK terminals are joined together through a closure, as with a Bogen CLK-6

31、A Master Program Clock. Telco Page is accomplished through a telephone audio pair plus closure. The audio pair connects to a WMT-1 transformer which is plugged into the TELCO PAGE jack. A 24-ohm resistor is connected in series with the closure across the CLOCK terminals. When both are included, the

32、time tone change option has precedence over Telco Page. EXTERNAL BOOSTER AMPLIFIER Model BPA-60 or BPA-125 (60 or 125 watts, respectively) pro- vides increased power output. To install, simply connect a cable, terminated with male phono plugs, from the MCP35 HI- Z BST INPUT jack to the HI-Z INPUT ja

33、ck on the rear panel of the amplifier. Connect the 25V OUTPUT from the amplifier to the l/4 phone jack (25V BST OUTPUT). SECTION TWO: Multi-Graphic PI-35 SYSTEM/SI-35 SYSTEM Capacity: TECHNICAL SPECIFICATIONS PI-35 System-25 Stations, maximum SI-35 System-25 Stations, expandable (in multiples of 25)

34、 to 75 stations Dimensions: PI-35: 8-l /2 “H x 20-l/2 “W x 11 “D (20.3 x 52 x 27.9cm) SI-35: 12 “H x 20-l /2 “W x 11 “D (35 x 52 x 27.9cm) Weight: PI-35: Approximately 20 lbs. SI-35: Approximately 35 lbs. Controls: Room Selector and Annunciator Panels-25 LED annunciators; 25 three-position switches-

35、PROGRAM, OFF, INTERCOM Finish: Cabinet-Simulated walnut veneer Panels-Bogen Sand with color-coded guides for PROGRAM, INTERCOM, and EMERGENCY PAGE. NOTE: All other specifications are the same as those given for the MCP-35. DESCRIPTION PI-35 System Bogen Multi-Graphic Model PI-35 High-Powered Interco

36、m utilizes the MCP35 Master Control Panel and one SBA225 Room Selector Panel. Facilities are provided for the distribu- tion of program information from external microphones, tuner, cassette player, or other background music source. SI-35 System Bogen Multi-Graphic Model SI-35 Desk-Top Control Cente

37、r incorporates the MCP35 Master Control Panel, and has a capacity of 75 speaker stations when configured with three SBA225 Room Selector Panels. If a built-in program source is desired, an FM/AM tuner can be incorporated with one or two switchbanks; an FM/AM tuner with cassette player can be used wi

38、th one switchbank. Calls from a speaker-equipped location in an PI-35 or SI-35 system, and speaker or staff handset in a Series 115 system, are received with light annunciation and a tone signal. When selected for intercom, or when a speaker station is monitored from the control center, a supervisor

39、y tone is repeated at regular intervals. Stations equipped with a CA-16 Call-In Switch can prevent monitoring and still hear incoming mes- sages when the switch is placed in the PRIVACY mode. ASSOCIATED EQUIPMENT SWITCHBANKS Bogen Model SBA225 Room Selector Panels are capable of connecting up to 25

40、speaker-equipped locations to a PRO- GRAM, OFF, or INTERCOM channel. Each unit provides 25 lever-action, three-position, four-pole selector switches with positive detents, and red LEDs. Switch positions are graphically identified as PROGRAM A, OFF 0, and INTERCOM C, each with color-coded indicia; th

41、e program channel color-code is amber, the off position color- code is black, and the intercom channel color-code is green. Each switch functions as follows: A-(Up position, amber color-code)-connects a speaker station to the Program channel for distribution of microphone, tuner, cassette player, or

42、 phono generated in- formation; is overridden by EMERGENCY PAGE. 0-(Center position, black color-code)-disconnects a speaker station from the system; is overridden by EMERGENCY PAGE and ALL ROOMS pushbuttons. C-(Down position, green color-code)-connects a speaker station to the Intercom channel; is

43、overridden by EMERGENCY PAGE pushbutton. Program information will not be distributed to this station if the switch is left in this position. A white tabular strip, protected by a clear plastic snap-off cover, is provided for labelling the station controlled by each selector switch. When stations are

44、 identified by numbers, it is common practice to connect and label the switches from left to right (as viewed from the front or operators position), starting at the uppermost switchbank. Calls from staff stations are initiated by momentary depression of a call-origination switch, which lights the co

45、rresponding LED on the SBA225, while sounding a repetitive tone to bring attention to the call. The LED remains “on” until the call is acknowledged by placing the appropriate switch to the “C” position. Each switchbank panel has provisions for accommodating the add-on Bogen Model TZMA Time Zone Modu

46、le, providing up to six zones of time signalling, and/or the Model SCR25 Call-In Module, providing the circuits necessary when using call-origination switches which do not contain silicon-con- trolled rectifiers. SWITCHBANK MODULES SCR25 Call-In Module Bogen Model SCR25 Call-In Module is an annuncia

47、tor latching control bank designed for use with the SBA225 Room Selector Panel. The SCR25 provides 25 silicon-controlled rectifiers and programmable DIP switches and permits the use of a momen- tary switch (such as the Bogen Model CA-17) and/or a telephone handset with fixed closure for call-in from

48、 a staff location. The silicon-controlled rectifiers provide annunciator latching, keeping the appropriate LED annunciator lamp illuminated until the call is acknowledged. DIP switches are provided to select the method of call-in (momentary switch and/or fixed closure handset). The module is connected to the switchbank panel by a simple plug-in method and is constructed of G-10 glass epoxy. Termi- nation is via wire wrap or centerline connectors (Panduit or equivalent). TZ