《Rauland Telecenter Iv - Ki-1405-2420 To 2422 Digital Clock 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter Iv - Ki-1405-2420 To 2422 Digital Clock 电路图.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。
1、RAWAND-BORG CORPORATION ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (708) 679-0900 This baffle assembly is hung with the hanger bracket supplied with the unit. The bracket can be attached to a standard single-gang electrical box or to a flat surface. Mounting the Baffle to an Electrical
2、 Box Parts needed: qty. Description 1. hanger braizket (AB1813) 3 (Supplied with %8-32 x 3/4 pan-head metal screw (WA721baffle assembly) tie-32 Vi, type speed nut (AB1818) 1 Standard single-gang electrical box 3 (Supplied by #6-32 machine screws of a suitable lengthcustomer.) Wiring from the control
3、 console to the baffle assembly: Step 1. Step 2. Step 3. Step 4. Step 5. Step 6. (See the applicable Rauland amplifier and 2400 Series master clock manuals.) If necessary,rough the outlet box into the wall. Pull through the wiring you need from the control console. Fasten the hanger bracket to the e
4、ars of the outlet box, using two #6-32 screws. Snap the speed nut, with the larger hole facing up, into the slotted hole of the bracket. Connect the system wires to the Digital Module and the speaker transformer (the connections are shown on the label inside the baffle). Hang the baffle on the brack
5、et and fasten them together with the pan-head screw. o 1984 RAIJT.ANTI-i3ORC CORF.PRNTET) T N 1l.S.A. 17/84 RadioFans.CN 收音机爱 好者资料库 Mounting the Baffle to a Flat Surface Parts needed: Same as page 1 except: QV. Description No electrical box or - 86 screws. 2 #8 screws that (a) are appropriate for th
6、e mounting surface (wood, sheet metal, plaster, etc.) and (b) will hold5% pounds. Step 1. Route the wiring from the control console want the baffle. Step 2. Fasten the hanger bracket to the mounting screws (see the Parts List above). Follow Steps 4 through 6 on page 1. to the place where you surface
7、, using appropriate SPEED NUT PAN-HEAD SCREW, BAFFLE ASStMULY RadioFans.CN 收音机爱 好者资料库 2421 FLUSH-MOUNT DIGITAL INSTALLATION MANUAL KI-1468B CLOCK RAULAND-BORG CORPORATION ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (708) 679-0900 PRELIMINARY INFORMATION DESCRIPTION The 242 1 consists of
8、 a 2420 Timer-Clock module plus a flush-mounting kit. As supplied, it is ready to be used as a secondary clock with the Model 2424, 2450, or 2490 series Master Clocks. With the 2423 Switch Kit, it can also be used as an elapsed timer (see m-1462). With other appropriate switches, it can be used as a
9、 stand-alone clock, a countdown timer, or a combination clock and timer (see the secondary-clock applications manual, K for hospital applications, Rauland recommends the use of a customer-provided 24-VAC power supply that provides electrical isolation. PARTS SUPPLIjED WITH THE 2421 The mounting kit
10、includes a black dress panel and the QV- hardware to attach the clock module and the panel to a 1 standard five-gang masonry box. The supplied wire nuts1 will take care of all of the electrical connections to the1 clock. A list of the parts supplied with the 2421 is given2 on this page.4 CUSTOMER-SU
11、PPLIED PARTS Whatever the configuration, the customer will have to supply a standardfive-gang masonry box (e.g., Race 694, Steel City GW-525-C). I If the 2421 is to be installed as a stand-alone clock or timer, the customer will have to supply tllc appropriate switches, anAC/,orcersourcc, and the to
12、iritq to tlw cl(Kk. 6 - CO1989 FIAULAND-BORG CORPORATION ? Prmted in U S A Orig. 5186 Rev. 9187; 2189 _-. Description Secondary clock-timer. Nine-pin pigtail Black front dress panel. Mounting brackets. #6-32 “U” nuts, to fasten the clock trans- former and the front panel to the mounting brackets. #6
13、-32 x !A” pan-head machine screws, to fasten the clock module and the transformer to the mounting brackets. #6-j2 x AL” pan-head machine screws, t o XSCTI the mounting brackets to the masonry tx,x Rauland Part No. 2420 - - - AN0943 -3357 ABZgO4 WA57 WA6 1 Page 1 of 4 2421 Flush-Mount Digital Clock Q
14、V- 2 Description #6-32 X W” black Phillips pan-head machine screvq to fasten the front panel to the mount- ing brackets. Flat washers, for the panel-mounting screws. large wire nuts, for connecting the trans- former wires to the power-supply or system wiring. Small wire nut, for insulating the unuse
15、d transformer wire. Rauland Part No. RELATED MANUALS WA137 WJoo74 QPO488 QpO489 2415 (24-VAC Power Supply). . . . . . . . . . . Kl-1356 24 16 (120-VAC Power Supply) . . . . . . . . . . . . KI-1355 24 17 (Adapter to mix analog and digital clocks). KI-1354 2418 (AC Output Buffer) . . . . . . . . . . .
16、 . . . . ICI-1386 2423 (Elapsed-Timer Switch Kit) . . . . . . . . . . . 1-1462 2424 (Master Clock) . . . . _ . . . . . . . . . . . . KI-1316 2490 (Master Clock) . . . . . . . . . . . . . . . KI-14% Applications for Rauland secondary clocks . _ . . . KI-1470 Secondaryclock correction with the 2490. .
17、 . . KI-1390 INSTALLATION Refer as necessary to IL0157 (page 3) for the following steps. Step 1. If necessary, rough the masonry box into the wall. Step 2. Consult the appropriate manuals from the above list and pull through the wiring from the power supply or the clock system and any switches that
18、are to be used with the unit. Do not apply power to these lines until it is time to test the installation. Step 3. Orient the mounting brackets as shown in ILO157. Place a “u” nut over the small center tab on the front of each bracket; the flat side of the nut should face the front. Step 4. Place th
19、e clock module and its attached trans- former on a suitable work surface. Orient a “U” nut so that its flat side faces the same way as the mounting base of the transformer, then push the “LJ” nut onto one of the narrow ends of the base. In like manner, install a second “U” nut on the opposite end of
20、 the base. Step 5. Orient the transformer so that the side with the wires attached to the clock module faces you and its mounting base faces to the left. Step 6. Place the transformer inside the left mounting bracket, align its “U” nuts with the holes in the brackets large flange, and secure the tra
21、nsformer to the bracket with two #6 x 4;” screws Step 7. Orient the clock module so that its LED display faces you and the electrical connections between the display and the circuit board are at the bottom. Use four #6 x Y? screws to secure the clock module to the threaded standof make sure that the
22、re is enough space between the back of the assembly and the box for you to work on the wiring and stuff it back inside the box. Step 9. Using the large wire nuts, attach the power- supply wires to the appropriate transformer wires of the clock: 24 VAC120 VAC BrownBlTXVn BlackBh? Note: For hospital i
23、nstallations, Rauland recommends the use of a customer-supplied isolating 24-VAC power supply that can furnish 300 mA to each clock. Step 10. Cover the end of the unused transformer wire with the small wire nut. CAUTION Never connect the black transformer wire to a 120-VAC power suppk, such a COMeCt
24、iOn will damage the module. Refer to the applicable power+wpply installation manual for additional information and instructions. 1 Step 11. If there are switches, connect their wires to the clock module now. Step 12. Carefully push the wires inside the masonry box and secure the brackets to the box
25、with the four #6 x SW screws. Step 13. Before installing the dress panel, you may wish to test the clock by powering it up and running the operations listed in the applicable manuals. However, if this is part of a partially completed system, you may prefer installing the panel first, to prevent dama
26、ge to, or loss of, these parts. Step 14. Place a stainless-steel washer on each of the two #6 x K” black screws, then place these parts within easy reach. Align the screw holes of the dress pane1 with the “u” nuts previously installed on the mounting brack- ets. Secure the panel to the brackets with the screws.