Rauland Ranger Classroom Installation 电路图.pdf

上传人:cc518 文档编号:220803 上传时间:2025-03-18 格式:PDF 页数:34 大小:1.07MB
下载 相关 举报
Rauland Ranger Classroom Installation 电路图.pdf_第1页
第1页 / 共34页
Rauland Ranger Classroom Installation 电路图.pdf_第2页
第2页 / 共34页
Rauland Ranger Classroom Installation 电路图.pdf_第3页
第3页 / 共34页
亲,该文档总共34页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Rauland Ranger Classroom Installation 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Ranger Classroom Installation 电路图.pdf(34页珍藏版)》请在收音机爱好者资料库上搜索。

1、Installation KI-1977B Rauland RANGER Classroom Installation Rauland-Borg Corporation Issued: 06/30/98 Page 1 of 34 RadioFans.CN 收音机爱 好者资料库 Copyright 1998 by Rauland-Borg Corporation, all rights reserved. This document contains users information on technology that is proprietary to Rauland-Borg Corpo

2、ration. Permitted transmittal, receipt, or possession of this document does not express license or imply any rights to use, sell, design or manufacture this information. No reproduction, publication, or disclosure of this information, in whole or in part, shall be made without prior written authoriz

3、ation from an officer of Rauland-Borg Corporation. Rauland-Borg Corporation Rauland-Borg Corporation 3450 West Oakton Street Skokie, Illinois 60076-2958 (847) 679-0900 RadioFans.CN 收音机爱 好者资料库 KI-1977B Rauland RANGER ClassroomInstallation Table of Contents INTRODUCTION. 4 SCOPE OF THIS MANUAL. 4 RELA

4、TED DOCUMENTS. 4 OBSOLETE UNITS. 4 CLASSROOM INSTALLATION. 5 RANCL101 CLASSROOM CONTROLLER. 5 Parts Required. 5 Associated Equipment. 5 Installation Steps. 7 RANCL101CP CLASSROOM CONTROLLER.11 Parts Required.11 Associated Equipment.11 Installation Steps.13 RANCL201 CLASSROOM CONTROLLER.15 Parts Requ

5、ired.16 Associated Equipment.16 Installation Steps.17 RANCL201CP CLASSROOM CONTROLLER.20 RANPCVID SUPER VIDEO WINDOWS CARD.25 Parts Required.25 Associated Equipment.25 LOADING FIRMWARE (SEND PANEL PROGRAM).27 STARTING THE SEND PANEL PROGRAM.27 Configuring a Single Classroom .30 RANGER CLASSROOM TV C

6、ONTROLLER INSTALLATION AND ADJUSTMENT .31 Required Equipment .31 Power/Current Adjustments.31 Video Adjustments: RANCL101/RANCL101CP.32 LEVEL III CONTROL.33 Set Classroom Panel Baud Rate.34 KI-1977B Rauland RANGER ClassroomInstallation Page 4 of 34 (Jun-98) Introduction Scope of this Manual This man

7、ual tells how to install the Ranger classroom units. This includes mounting and wiring the individual units as well as configuring the related software on the Media Center computer. Related Documents For information on the wiring at the Media Center and configuring the system software, see KI-1856.

8、Obsolete Units New installations will center on hand-held remote controls. Accordingly, the RANCLASS1, RANCLASS2, and RANCL201 are no longer available, and the RANCL101 will only be used in place of AVDS2 units. This manual includes information about these older units as a convenience for those work

9、ing with older systems. 1 KI-1977B Rauland RANGER ClassroomInstallation Page 5 of 34 (Jun-98) Classroom Installation RANCL101 Classroom Controller The RANCL101 is a baseband classroom electronics unit that mounts directly on either a Bretford or Peerless television mount (other mounts may require th

10、e drilling of 4 mounting holes) and is primarily designed to function in tandem with the RANCLASS1 or RANCLASS2 Classroom Control Panel. The unit resembles a small VCR and includes the following features: IR detector and transmitter, local/headend audio/video switching (when used with a RANCLASS1 or

11、 RANCLASS2), audio/video demultiplexing, connections for Level III laser disc control, stereo audio with improved performance and automatic stereo/mono switching, video coaxial equalizer for improved video signal, and accommodations for mounting a RANAVMS1 (stereo multiplexer for distributed local o

12、rigination). This unit is no longer available. Parts Required 1AC Outlet 1RANCLASS1 or RANCLASS2 Associated Equipment 1Classroom monitor mount (e.g., RANHRDS27) 1RANMONxx (e.g., RANMON27) 1RANCLASS1 (only for classrooms with classroom panel) 1RANBOX2 (for surface mounting of RANCLASS1 only) 1 VW2290

13、-372 (refer to drawing for the VW2290-372) (supplied with the RANCL101) 1Control Link wire (e.g., WPD291, if used with a RANCLASS1) 1175 video cable (e.g., WP815) or Fiber Optic cable (from headend) 1VP0400, IR Transmitter Cable (supplied with the RANCL101) 1RANCLINTF TV Interface Box (optional) 2 K

14、I-1977B Rauland RANGER ClassroomInstallation Page 6 of 34 (Jun-98) 1Two-Gang Electrical Box (if RANCLINTF is used) 1 AB3905 Mounting Bracket for the RANCL101CP (supplied with the RANCL101) 1 VW2290-336 (refer to drawing for the VW2290-336) (supplied with the RANCL101) KI-1977B Rauland RANGER Classro

15、omInstallation Page 7 of 34 (Jun-98) For Local Origination 1RANAVJ Audio and Video Jack 1 RANAVMS1 Audio/Video Multiplexer Module (installs inside the RANCL101 for systems that require distributed local originationsee “RANAVMS1” for more information) For Fiber Systems 1RANFBINT, Fiber interface box

16、(used instead of RANCLINTF) 1 RANFT1 or RANFT1FM Fiber Transmitter Card (only for return video on systems with local origination) 1RANFR1 or RANFR1FM Fiber Receiver Card 1 RANBOX4 (only for surface mounting the RANFBINT) or Hoffman Engineering 8 10 4 back box, part number A-SE10X8X4. Note: (a) The 1

17、 Pair Shielded wire can be looped from one classroom to another as long as it does not exceed the maximum distance per AXLINK port specified in the “RANBROAD,” “RANEXP,” “RANEXPAD,” or “RANCPU” sections. (b) The control pair can also be run as independent AXLINKS. Each link is subject to the specifi

18、cations for maximum distance per AXLINK port specified in the “RANBROAD,” “RANEXP,” “RANEXPAD,” or “RANCPU” sections. Installation Steps Headend to Classroom Wiring Pull the following wires from each classroom to the Media Center. 175 Video Cable (e.g., WP815) This connects J13 on the RANCLINTF (Hea

19、dend Video) to the video matrix switch output. or 1Fiber Optic cable (e.g., WP92022). This connects J3 on the RANFR1 to the 0RANFT4 or RANFT1 (headend fiber transmitter). 11-Pair Shielded wire if using a RANCLASS1 (e.g. West Penn D291). This is the RS485 control link that originates at the headend f

20、rom one of the following: RANCC16 Punch Block RANBROAD RANEXP RANEXPAD (a RANEXP is needed with this unit.) Return Video to the Headend (Distributed Local Origination) 175 Video Cable (e.g., WP815). This connects J10 on the RANCLINTF to the video matrix switch input. or 1Fiber Optic cable (e.g., WP9

21、2022) from J3 on the RANFT1 to the RANFR4 or RANFR1 (headend fiber receiver). Wiring the RANCLINTF 1. Mount the two-gang box that will hold the RANCLINTF. This must be located within five feet of the RANCL101. KI-1977B Rauland RANGER ClassroomInstallation Page 8 of 34 (Jun-98) 2. Route the wires int

22、o the two-gang box that will hold the RANCLINTF and terminate the 75 video cable with a phono plug connector. 3. Connect the 75 video cable that you just have terminated and connect it to the J13 (Headend Video) terminal on the RANCLINTF. 4. If using a RANCLASS1, strip back the 1 Pair Shielded contr

23、ol wire (e.g., West Penn D291) and connect it to J11 on the RANCLINTF (see Table 1. for more information). Table 1. Control Cable Wire Colors(J11) on the RANCLINTF Male DB25 Pinout (w/out RANCLINF) AXPI (Red)J11-5 (AXPI)3 AXMI (Black)J11-6 (AXMI)16 GND (Shield)J11-7 (GND)4 or 17 Note: The colors of

24、the Control Cable wires may change depending on the type of cable you are using. Connecting the RANCLINTF to the RANCLASS1 1. Strip back the outer case of the 9 pair shielded wire. 2. Strip 16 of the wires about 1/8 of inch. 3. Put electrical tape around the 2 unused wires so they do not cause a sho

25、rt. 4. Crimp the 16 remaining wires to the 16 pigtail wires according to the order specified in the following table: Table 2. RANCLASS1 Wiring January 16, 1995 Version 1.1 Signal RANCLINTF Pin # Pigtail Color Pigtail Pin# RANCLASS1/ RANCLASS2 V2.0 or later Distributor Wire Color Used for Interconnec

26、t Male DB25 Pinout without RANCLINTF IRINJ11-1Black1J1-11 IROUTJ11-2Brown2J1-214 +12VJ11-3Red3J1-32 +12VJ11-4Orange4J1-415 AXPIJ11-5Yellow5J1-53 AXMIJ11-6Pink6J1-616 GNDJ11-7Blue7J1-74 GNDJ11-8Violet8J1-817 IO1-Local / Headend Select J11-9Gray9J2-15 IO2-TV Off Sense J11-10White10J2-218 IO3-TV On Sen

27、se J11-11Red11J2-36 IO4-Motion Detector Output J11-12Black12J2-419 KI-1977B Rauland RANGER ClassroomInstallation Page 9 of 34 (Jun-98) Table 2. RANCLASS1 Wiring January 16, 1995 Version 1.1 Signal RANCLINTF Pin # Pigtail Color Pigtail Pin# RANCLASS1/ RANCLASS2 V2.0 or later Distributor Wire Color Us

28、ed for Interconnect Male DB25 Pinout without RANCLINTF IO5-Motion Detector Supervision J11-13Orange13J2-57 IO6-FutureJ11-14Yellow14J2-620 IO7-FutureJ11-15Pink15J2-78 IO8-FutureJ11-16Blue16J2-821 AXPIJ9-1Black1 AXMIJ9-2Brown2 GroundJ9-3Red3 GroundJ9-4Orange4 +12VJ9-5Yellow5 -12VJ9-6Pink6 +5VJ9-7Blue7

29、 RTSJ9-8Violet8J3-5 (for level III only) 9 CTSJ9-9Gray9J3-4 (for level III only) 10 TxDJ9-10White10J3-2 (for level III only) 11 RxDJ9-11Red11J3-3 (for level III only) 12 RxDJ9-12Black12 Motion Detector Sense J9-13Orange13 I06-FutureJ9-14Yellow14 I07-FutureJ9-15Pink15 I08-FutureJ9-16Blue16 Note: The

30、colors of the wires do not matter, but make sure they match as described in the above chart. Note: The RANCLASS1 will only read the DIP Switch setting when it powers up. If the address needs to be changed when the unit is on, power down for several seconds and power up again. 5. After making all the

31、 necessary connections to the inside of the RANCLINTF, secure its front-cover plate. Then secure the RANCLINTF to the two-gang electrical box with four mounting screws. 6. With the unit open set the DIP switches on the RANCLASS1 for the appropriate classroom (control) address. These addresses must b

32、e entered into the Media Centers classroom databaseaddresses should be after the RANCC16 addresses and up to 254. Make sure that there are no two panels with the same address code. The number in the code value row in the example below indicates the value of that DIP switch when it is in the “ON” pos

33、ition. The following example shows the DIP switch settings (switch numbers 1,3,7, otherwise, you can skip ahead to the next section. 1. Mount a single gang electrical box in the appropriate location. This will be used for the RANAVJ wall plate. 2. Mount the RANAVMS1 into the RANCL101 using the follo

34、wing procedure: a.Add the four snap-in posts onto the board (look for mounting holes in the area near J10. b.Connect the RANAVMS1 by pushing the pin holds over the pins marked J10 on the RANCL101. Push the board so that it snaps-securely into place. c.Secure the top cover to the RANCL101. 3. Route t

35、he 75 coaxial cable from the RANAVJs video terminal (single gang box) to the RANCLINTF (or the RANFBINT) and terminate the 75 video cable with the Phono plug connector at the RANCLINTF (or the RANFBINT). 4. Route two 1- Pair shielded wires (e.g., West Penn D291) from the single-gang box to the RANAV

36、J. 5. Strip back the (2) 1- Pair shielded wires (e.g., West Penn D291) and terminate the ends with an RCA plug. Connect them to the RANCLINTFs Local Right Audio (J8) and Local Left Audio (J7). Connect the other end to the RANAVJs Left Audio terminal and the Right Audio terminals. 6. Connect one end of the terminated 75 video cables to the RANCL101 (Local Video). 7. Connect th

展开阅读全文