《Rauland Td21 And 1100 - 9556 Replacement Firmware 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Td21 And 1100 - 9556 Replacement Firmware 电路图.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。
1、Installation KI-1833 9556 Replacement Software for Telecenter System 21 Rauland-Borg Corporation Issued: 06/26/98 Page 1 of 6 RadioFans.CN 收音机爱 好者资料库 Copyright 1998 by Rauland-Borg Corporation, all rights reserved. This document contains users information on technology that is proprietary to Rauland
2、-Borg Corporation. Permitted transmittal, receipt, or possession of this document does not express license or imply any rights to use, sell, design or manufacture this information. No reproduction, publication, or disclosure of this information, in whole or in part, shall be made without prior writt
3、en authorization from an officer of Rauland-Borg Corporation. Rauland-Borg Corporation Rauland-Borg Corporation 3450 West Oakton Street Skokie, Illinois 60076-2958 (847) 679-0900 RadioFans.CN 收音机爱 好者资料库 KI-1833 9556 Replacement Software for Telecenter System 21Installation Table of Contents GENERAL
4、INFORMATION. 4 ?. 4 ALERTS, PRECAUTIONS, AND LIMITATIONS. 4 ? ?. 4 ?. 5 INSTALLATION. 6 ?. 6 KI-1833 9556 Replacement Software for Telecenter System 21Installation Page 4 of 6 (06/26/98) General Information ,QVWDOODWLRQ?1RWHV The 9556 Replacement Software consists of one chip labeled “U7.” It contai
5、ns the most recent software for Telecenter System 21. You can use it to replace a damaged chip or to upgrade a system from an earlier version of software. Alerts, Precautions, and Limitations ? CMOS devices are easily damaged by static electricity. Leave the chip in its protective bag and foam until
6、 you are ready to install it. ? Use an approved static control wrist strap whenever you handle the chip or work on the central system. 7RROV?DQG?6XSSOLHV Installing the chip requires the following hand tools. ? IC extractor (for 28 pin DIP) or a small, thin, stubby flat blade screwdriver. 1 KI-1833
7、9556 Replacement Software for Telecenter System 21Installation Page 5 of 6 (06/26/98) 3DFNLQJ?/LVW The 9556 Replacement Software for Telecenter System 21 is packaged one to a box. Each package should contain the following: QuantityPartPart Number 132 pin DIP Integrated Circuit (chip) in ESD shieldin
8、g (bag and foam). ED0516 1TD21 Programming and Diagnostic Software Diskette (3.5”). VP0370 1Telecenter System Programming Manual. KI-1768 19556 Replacement Software for Telecenter System 21 Installation Manual. KI-1833 KI-1833 9556 Replacement Software for Telecenter System 21Installation Page 6 of
9、6 (06/26/98) Installation 0HFKDQLFDO?,QVWDOODWLRQ 1. Turn off the system. Remove the SCC board from the central chassis by disconnecting all wires from the screw terminal and then removing the screws on the DB9 connector for the serial board. 2. Remove chip U7 from its socket. If you do not have a c
10、hip extractor, use a small, thin, stubby flat blade screwdriver to loosen the chip at each end. Avoid twisting the chip, that might bend or break its pins. Place the chip on conductive foam for safekeeping. 3. Insert the chip into the socket indicated on its label. The notch in the chip should match
11、 the screening on the board, and no pins should be bent under the chip or hang outside the socket. 4. Reinstall the SCC board in the system, then turn on the power. 5. Make any needed programming changes in accordance with the appropriate Telecenter System 21 programming manual. 6. If the customer wants the programming mode disabled (to prevent accidental or unauthorized changes), place the programming jumper in the “DIS” position. 2