1、KI-1237A TZC25 and TZC25 Time Panels Installation RAUDBQROCOWOFIATIQN l 3450 West Oakton Street, Skokie, Illinois 60076-2951 l (847) 679-0900 Preliminary Description The TZ25 Time Zone Panel works with any of the selector switch panels used in Director Series Systems to connect remote room speakers

2、for time-tone signaling. The TZC25 Time Zone Panel is similar to the TZ25, except that it is designed for rack mounting and is used without a selector switch panel. It is primarily used for special functions in TelecenterSecurity Systems. Time Signaling A ground signal from the zone relay contacts o

3、fa program- mable clock, such as the Rauland 2424, is the “ Z” input to the Zone Patch Panel for time-signal distribution. The output of the Zone Patch Panel to the “ R” connector on the TZ25 energizes relays for the selected remote station in order to send the time tones there. A TCMS time-zone osc

4、illator plus a suitable power amplifier supplies the time signal to the “ S” connector on the TZ25. Bracket Modification equipment such as the TW25 Two-Wire Adapter can be plugged onto the terminals (“ piggy-backed” ). .,.,. .I As was announced in Tech Bulletin no. 191 (June 25, In factory-wired sys

5、tems, terminals OFF-l, OFF2, A-l, 1987), the mounting bracket of the TZ25 has been modified A-2, Bl, B2, C-l, and C-2 are interconnected. These inter- so that it can be used “ as is” on SW25 and SWL25 panels. connections provide loop-through for common functions; However, it must be modified before

6、it will fit properly on they are described in the manuals provided with the related SWT425 and SWL425 panels. program and intercom panels. Refer to the attached IL0269 for the following steps: Step 1. Remove and set aside the two sheet-metal screws that secure the board-support bracket to the side b

7、rackets. To connect the field wiring directly to the TZ25, refer to the wiring installation procedures below. Step 2. Rotate the support bracket 180” vertically: the card holders will still face frontward but the tabs that fit against the side brackets will now be on top. Cable Requirements Step 3.

8、Rotate the support bracket 90” axially, so that the tabs now point to the rear and the card holders face upward. A shielded cable with one twisted pair connected to ter- minals E and D and the shield connected to terminal G is required for each remote station. Terminals T, A, and L are used only whe

9、n the selector switch panel has call-in circuitry. The T terminal requires a third wire to the station. Step 4. Unsnap the card holders, then snap them into the adjacent holes in what is now the rear side of the support bracket. Step 5. Use the two screws that you set aside in Step 1 to re-secure th

10、e support bracket to the side brackets. Use 22-AWG solid conductors. The diameter of the indi- vidual wires, including insulation, should not exceed 0.095 inches for insulation-piercing connections. The field wiring must be totally supported with cable ties or clamps secured to the chassis cut-outs

11、or extrusions. L . . . . . . . / Output Connections Both the TZ25 and the TZC25 are equipped with 110 square-pin terminals on the rear edge of the printed circuit board. The field wiring can be connected directly here, or Wiring The connections to the panel s rear terminals may be made by insulation

12、-piercing connectors, wire-wrapping, or crimp connectors. These methods are taken up in the following sub-sections. 81988 RAULANDBORG CORPORATION l Printed in USA Page 1 of 6 Orig. 10/81. Rev. 3/88. 2d Printing 7/96. RadioFans.CN 收音机爱 好者资料库 TZ25 and TZC25 Time Panels Insulation-Piercing Connectors T

13、he Rauland SK-2522 includes 25 connectors. See the attached manual, KI-1564, for installation instructions. Modified Wire- Wrapping You will need a wire-wrap tool such as the Gardner-Den- ver Model 144-1C or Model A-205577-31. Step 1. Strip back the cable sheathing and the shield about 1 V2 inches f

14、rom the end of the cable. Step 2. Strip back about one inch of the insulation on the individual wires. Step 3. Use a wire-wrap tool to wrap each bare wire around the appropriate terminal; be sure to add one complete turn of the insulated part of the wire as a necessary strain relief Leave about two

15、inches of slack in each wire to accommodate possible future connections. . . . . . . . . . . . . . . . # Crimped Connectors The Rauland CTA25 Terminal Adapter Kit consists of25 four-terminal adapter housings and 100 crimp connectors. To make good connections, use a Molex Model HTR-2445-A crimping to

16、ol (Order Number 11-01-0026). Step 1. Strip back the cable sheathing and the shield about I U2 inches from the end of the cable. Step 2. Strip about t/a inch of insulation from each indi- vidual wire. Step 3. Use a crimping tool to fasten the wires to the connectors. Step 4. Insert the connectors in

17、to proper terminals of the adapter housings. Page 2 3/88 RadioFans.CN 收音机爱 好者资料库 FIGURE 2 MOUNTING INSTRUCTIONS FOR 1 TZ 25 TIME ZONE ADAPTER WITH SWL 25, SW 25, SWT 425, SWL 425. SW 25 OR k . . . . . . . . i SWL 25 TZ 25 SIDE BRACKET SIDE BRACKET T W 25 (SEE NOTE 1.1 L,-,-, MOUNTlNG HOLE PAIR INSUL

18、ATOR TW 25 TWO- WIRE ADAPTOR tS NOT USED WITH SW 25 WHICH IS NOT EQUIPPED WITH ANNUNCIATOR OR LE D S. SWT425 SIDE BRACKET SWL 425 SIDE BRACKET MOUNTING HOLE PAIR L TZ 25 SIDE BRACKET we- TW 25 MOUNTING HOLE PAIR i TZ 25 SIDE BRACKET TW 25 NOTE: L FRONT m L yAy K) )K NOTES : I. THE MODEL TZ25 CAN BE

19、USE0 WITH ROOM SELECTOR PANELS SW25. SWL25. SW425 AND SWL425. IT ATTACHES TO THE REAR OF THE ROOM SELECTOR PANEL 2. THE MODEL TZC25 CAN BE USED WITHOUT A ROOM SELECTOR PANEL. BUSSING STRIPS ARE PROVIDED WITH THE MODEL TZC25 INSTEAD OF RECEPTACLES TO CONNECT ALL NORMALLY CLOSED ROOM RELAY CONTACTS TO

20、 THE OFF I AND OFF 2 TERMINAL PAIR. 3 THE MODEL TW25 TWO-WIRE ADAPTER MAY BE USED TO PROVIDE TWO-WIRE ANNUNCIATION THROUGH THE T TERMINALS TO AN ASSOClATEO ROOM SELECTOR PANEL OR TO THE TELECENTER II SYSTEM 4 FlELO WlRlNG TERMINATES DIRECTLY WITH THE TZ25 OR TZC25. OR TO THE TW25 IF USE0 IN THE SYST

21、EM. G 7 G r OFF L2 Tl C L2) , ) I 1 OFF 2J NOTE:2. OFF1 AND OFF 2 WAS AI AND 12. 5. 110 SQUARE PIN TERMINALS CO.0451 ARE PROVIDED ON REAR OF THE TZ25 OR TZC25 FOR FIELD WIRING OR PLUG- IN OF ASSOCIATED PIGGYBACK- MOUNTED EOUIPMENT. 6. 110 SQUARE PIN FEMALE RECEPTACLES IO.0451 ARE PROVIDED ON FRONT O

22、F THE TZ25 FOR PLUG-IN ON REAR OF ASSOCIATED ROOM SELECTOR PANEL. N.O. N.C. COM EACH RELAY HAS TWO SETS OF FORM C CONTACTS. ALL RELAYS ARE PART . 2 : . . . . . . *. .* . : : . . . *. : . . NUMBER D- 0236: COIL RESISTANCE IS K -; 26 VOC. RYI-RY26 BASE DETAIL R 8 1 CONNECTORS MATING PINS SHOWN. SEE CH

23、ART BELOW FOR CIRCUIT NUMBERS TOP VIEW FRONT CIRCUITS FOR ROOMS 3 THROUGH 25 ARE WIRED THE SAME AS SHOWN FOR ROOMS I AND 2 ABOVE. ?.I GOES TO D ODD AND E EVEN ROOMS. 52 GOES TO 0 EVEN AND E ODD ROOMS. R AND T CONNECTOR PIN TO ROOM ClRCUlT CROSS-REFERENCE CHART TOP VIEW OF PC BOARD REAR S CONN ZONE A

24、MP BUSS FLAT CABLE r- CONN. R +26VDC X RI4 IS +ZBVDC. XY FLAT RIBBON CABLE WIRES ARE NUMBERED 1 (RED) TO 26 CONSECUTIVELY AND ARE WIRED TO CORRESPONDING PIN NUMBERS OF RESPECTIVE R OR T CONNECTOR I N4D02 , I.- GROUND SIGNAL c-b ENERGIZES RESPECTIVE ROOM SELECT RELAY AND THE S-BUSS RELAY. TIME ZONE A

25、DAPTERS MODELS TZ25 AND TZC25 RAULAND-BORG CORP CHICAGO, ILL MADE IN USA KC-1347- m SEE CHART TO RIGHT FOR PROPER CIRCUIT NUMBER. NEG SUPPLY FN PSX30 ZPPCSO ZONE PATCH PANEL ( 50 ROOMS1 ADDITIONAL CIRCUITRY PROVIDED FOR ZPPCIOO ZCM PATCH PANEL (IO0 ROOMS) ROOMS 1-25 RWMS,26-50 ROOMS 51-75 ROOMS 76-100 I I I ZPPcl00/ZPPC50 ZOM PATCH PANEL RAmAN) BcrlG COW C”hlM ILL WaDE IN ” s a KC-l367-