《C12,c22,l20 Owner's Manual (1) 电路图.pdf》由会员分享,可在线阅读,更多相关《C12,c22,l20 Owner's Manual (1) 电路图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。
1、OPERATION MANUAL C12 C22 L20 Plug-In Controller Modules L20 Limiter Module C22 Controller Module C12 Controller Module RadioFans.CN 收音机爱 好者资料库 2 C12 C22 L20 OPERATION MANUAL Table of Contents Table of Contents2 Introduction2 Installation3 C12 Loudspeaker Controller Module3 Input Connections4 Output
2、Connections4 C22 Loudspeaker Controller Module4 Output Connections5 Input Connections5 Ground Lift Switch5 Selector Switches5 C22 Setup Switches6 L20 Limiter Module6 Looping Outputs6 HPF Selectors6 Input Connectors7 Limit Set Switches7 Output Mode Selector7 Ground Lift Switch7 Block Diagrams C12 Con
3、troller Module8 C22 Controller Module8 L20 Limiter Module8 Congratulations on your purchase of a Renkus-Heinz loudspeaker controller module for your P2400 or P2700 dual-channel power amplifier. Your Renkus-Heinz amplifier and controller module have been designed to provide years of trouble- free, hi
4、gh performance operation. We hope you enjoy them. Your Renkus-Heinz controller module was completely tested and inspected before leaving our factory and should have arrived in perfect condition. Please carefully inspect the module and its shipping carton for any noticeable damage and immediately not
5、ify the shipping company if you see any noticeable damage. Only you (the consignee) may institute a claim with the carrier for any damage incurred during shipping. If you have a problem, be sure to save the carton and all packing materials for the carriers inspection. Important Renkus-Heinz controll
6、er modules contain no user-serviceable parts and all service should be referred to qualified service personnel. We recommend that any module be returned to the factory in its original packing carton if factory service is required. Introduction RadioFans.CN 收音机爱 好者资料库 3 C12 C22 L20 OPERATION MANUAL I
7、nstallation Procedure Installation The installation procedure is the same for all loudspeaker controller modules. 1. Remove the existing module from the rear of the amplifier by taking out the 4 mounting screws that hold the module in place and gently pulling the module out of the amplifier chassis.
8、 Caution: Before removing the existing module from the amplifier, make sure the amplifier is disconnected from the main AC line. 2. Remove (disconnect) the flat wire cable/connector that connects the existing module to the amplifier. 3. Connect the flat wire cable/connector to the new module you are
9、 installing. Then gently insert the new module into the amplifier and secure it into place with the 4 mounting screws you originally removed. Note: The C12 controller module has 2 flat wire cable connectors on the PC board. The one to use is the one having the most pins. It is designated J12 on the
10、PC board. Caution: C12 modules are configured for use with a particular loudspeaker and C22 modules are customized for use with particular loudspeakers by the proper setting of several control switches. Make sure the module is set up to operate with your loudspeaker(s) before connecting the loudspea
11、ker(s) and turning on the system. The C12 loudspeaker controller module shown above is a single input input, dual output module used in single channel (mono) systems having either active 2-way loudspeakers (or 3-way loudspeakers set up for bi-amp operation) or in systems having full-range (passive)
12、loudspeakers and subs (refer to the block diagrams show below.) It provides crossover circuitry, protection against overload damage, and frequency response smoothing. The C12 is customized to match its associated loudspeakers with a PK-xxx kit that provides the necessary settings for the crossover,
13、protection, and equalization circuitry. There is no need to adjust the C12 before installing it. C12 Controller Module T O REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOR REMOVE COVER (OR BACK) NO USER SERVICE
14、ABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MANUFACTURED IN EEC BRIDGE 21 OUTPUTS STEREO 4 OHM MIN./CH. BRIDGED MONO 8 OHM MIN. T 10 A 250 V 117 V RISK OF ELECTRICAL SHOCK DO NOT OPEN IRVINE, CA - U.S.A. POWER CONSUMPTION : 920 W SERIAL N MODEL P-2400 Input cc PIN 1 = GND PIN 2
15、= + PIN 3 = - MODEL C12 SUB/LF OUT FR/HFINPUT RENKUS-HEINZ MADE IN USA Channel 1 used to drive additional amplifiers. Note: When the C12s controller outputs are used to drive additional amplifiers, it is imperative that the amplifiers level controls be set at the same or a higher level than the leve
16、l of the amplifi- ers being driven. Otherwise, the protection feature is lost for the other amplifiers. The C22 loudspeaker controller module shown above is a dual input, dual output controller designed for use in stereo systems having either passive loudspeakers or subwoofers. It provides protectio
17、n against overload damage for the loudspeakers or subs, as well as high provide looping controller processed outputs for use in driving additional amplifiers. 2 used to drive additional amplifiers. An internal selector switch determines whether this connector provides a full-range looping output or
18、a processed band-limited high pass filter output. Refer to Selector Switches below for further information. 3 & 5. Channel 2 & 1 Audio Input Connectors Female 3-pin XLR type input connector for Channel 2 & 1. Refer to Audio Input Connector under the C12 for additional details. 4. Ground Lift Switch.
19、 The Ground Lift switch is used to separate the signal ground circuit from the amplifier ground circuit and thus, eliminate hum induced by ground loops. In the right position, the input signal ground is electrically connected to the amplifier ground circuit (the chassis). In the left position, only
20、an AC connection is provided between the signal ground and the amplifier ground circuit (the chassis). Note: When the processed controller outputs are used to drive additional amplifiers, it is imperative that the amplifiers level controls be set at the same or a higher level than the level of the a
21、mplifiers being driven. Otherwise, the protection feature is lost for the other amplifiers. 4. Selector Switches The C22 Loudspeaker Controller Module has several selector switches and a Stereo/Bridging Jumper plug that are accessible when the module is outside the amplifier. The location of these c
22、ontrols is shown in the outline drawing on the next page. The Looping/HPF switches control the signals to the Looping/HPF output connectors. In the Filtered position, the associated output connector is connected to the output of that channels high pass filter. In the other position, the connector pa
23、rallels that channels input connector and servers as a looping output. The HPF setting is used to deliver a band-limited signal to an additional amplifier for non-overlap operation (refer to the system wiring diagram on the previous page for further information.) The Stereo/Bridging Jumper plug is u
24、sed to bridge the two output channels together to provide a single output with twice the power capabilities of a single channel. Note that the Jumper Plug is located under the right PK22-xxx kit, which must be removed (unplugged) to gain access to the Jumper Plug. Input Connections Ground Lift Switc
25、h C22 Controller Module (continued) Selector Switches GROUND LOOPING / HPF PIN 1 = GND PIN 2 = + PIN 3 = - CH 2 OUTPUTS MODEL C22 PROCESSEDLOOPING / HPF CH 1 INPUTCH 2 INPUT RENKUS-HEINZ MADE IN USA CH 1 OUTPUTS 1325674 PROCESSED Output Connections 6 C12 C22 L20 OPERATION MANUAL The switches identif
26、ied as sw 1, sw 2 and sw 3 are used to configure the C22 for specific loudspeakers. The proper settings for these switches are shown in the enclosed charts. The L20 is a dual-channel limiter module. It is not loudspeaker specific and is provided with user adjustable limit and HPF (high pass filter)
27、controls (refer to drawing on next page). It is used to provide limiting on both amplifier channels (loudspeaker protection) plus low frequency rolloff. 1 & 6. Looping Audio Output Connectors These male 3-pin XLR type connectors are wired in parallel with the input connectors and provide unprocessed
28、 looping Channels 1 and 2 outputs. They allow looping through to additional amplifiers. 2 & 5. HPF Selector Switches Three position switches allow the Channel 1 and 2 low frequency rolloff points to be set at either 30 Hz, 60 Hz or 100 Hz to protect small loudspeakers from over excursion damage. C22
29、 Setup Switches HPF Selectors Looping Outputs L20 Limiter Module Filtered Filtered Stereo Bridged Stereo/Bridged Jumper Plug Looping/HPF Selector Switches sw 3sw 3 sw 2 sw 2 sw 1 sw 1 PK22-xxx KitPK22-xxx Kit C22 Controller Module Physical Layout C22 Controller Module (continued) T O REDUCE THE RISK
30、 OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOR REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MANUFACTURED IN EEC BRIDGE 21 OUTPUTS STEREO 4 OHM MIN./CH. BRIDGED MONO
31、8 OHM MIN. T 10 A 250 V 117 V RISK OF ELECTRICAL SHOCK DO NOT OPEN IRVINE, CA - U.S.A. POWER CONSUMPTION : 920 W SERIAL N MODEL P-2400 Ch. 1 Input Channel 1 Channel 2 Channel 1 and 2 outputs to loudspeakers. Channel 1 & 2 looping outputs (unprocessed signals) to additional power amplifiers, Ch. 2 In
32、put PIN 1 = GND PIN 2 = + PIN 3 = - MODEL L20 CH 1 INPUTCH 2 INPUTCH 1 OUTPUT CH 2 OUTPUT GROUNDSTEREO LIMIT SET BRIDGE LIMIT SET HPF SELECTHPF SELECT PARALLEL X 7 C12 C22 L20 OPERATION MANUAL 3 & 4. Audio Input Connectors Female 3-pin XLR type input connectors for Channels 1 and 2. Refer to section
33、 6 on page 9 for wiring details. 7 & 10. Limit Set Switches Three position switches allow the Channel 1 and 2 maximum output levels to be set at either 100, 200 or 350 watts into 8 ohms (400, 800 or 1400 watts in bridge mode). 8. Stereo - Parallel - Bridge Output Mode Selector The Output Mode Select
34、or allows the amplifer to be operated in 3 different output modes. In the Stereo mode, the two channels operate independently, just as they do in a stereo amplifier: signals fed into the two amplifier inputs are amplified separately and delivered in phase to outputs 1 & 2. The output levels are cont
35、rolled separately by the front panel mounted attenuators. In the Parallel mode, input 2 is disabled and the two amplifier channels operate in parallel from a single input signal fed into the Channel 1 input. This eliminates the need to install a jumper cable to operate the amplifier channels in para
36、llel. The outputs are separate and in phase and both input attenuators are active to permit different level settings for each channel. In the Bridge mode, a single signal fed into the Channel 1 input, drives both output channels in tandem and the output is delivered to the Bridge Output connector. T
37、his mode allows the two amplifier outputs to be strapped together ( bridged) to produce a single output with double the power capabilites of a single channel. Input #2 is disabled. Both input attenuators are active and must be set to the same level. Note that in bridge mode both sides of the output
38、should be consid- ered hot and should not be grounded and that the Limit and HPF switches should be set in the same position. 9. Ground Lift Switch. The Ground Lift switch is used to separate the signal ground circuit from the amplifier ground circuit and thus, eliminate hum induced by ground loops.
39、 In the left position, the signal ground is electrically connected to the amplifier ground circuit (the chassis). In the center position, the input signal ground is electrically disconnected from the amplifier ground circuit (the chassis). In the right position, an AC only connection is provided bet
40、ween the signal ground and the amplifier ground circuit (the chassis). Input Connectors Limit Set Switches Output Mode Selector Ground Lift Switch L20 Controller Module (continued) 132564 PIN 1 = GND PIN 2 = + PIN 3 = - MODEL L20 INPUTOUTPUT GROUNDSTEREO LIMIT 100 200 350 BRIDGE HP FILTER PARALLEL 7
41、9810 X CH 2OUTPUTINPUTCH 1 (400) (800) (1400) BRIDGE 100Hz 60Hz 30Hz (400) (800) (1400) BRIDGE HP FILTER 100Hz 60Hz 30Hz LIMIT 100 200 350 RENKUS-HEINZ MADE IN USA 8 C12 C22 L20 OPERATION MANUAL RH 368 33/97 17191 Armstrong Ave.Tel 714-250-0166 Irvine, CA, 92614Fax 714-250-1035 Peak Limiter Peak Lim
42、iter Low Pass Filter Low pass Filter Diff. Amp Ch. 1 Input + Ch. 1 Looping Output Ch. 2 Looping Output L20 Limiter Module Block Diagram Diff. AmpCh. 2 Input + High Pass Filter Parallel/Stereo/Bridge Switch Channel 1 HPF Jumper Channel 2 HPF Jumper To Ch. 1 Amp. To Ch. 2 Amp. High Pass Filter Ch. 1 P
43、rocessed output Excursion Limiter Peak Limiter High Pass Filter Low Pass Filter Thermal Limiter Diff. Amp Diff.Amp EQ Ch 1 Looping/ HPF output To Ch.1 Amp. High Pass Filter Diff. Amp Input Ch. 1 Ch. 2 Processed output Excursion Limiter Peak Limiter High Pass Filter Low Pass Filter Thermal Limiter Di
44、ff.Amp EQ Ch 2 Looping/ HPF output High Pass Filter Diff. Amp Input Ch. 1 Inverter Diff. Amp To Ch. 2 Amp. Ch. 1 Looping/ HPF Switch Looping HPF Looping HPF Ch. 2 Looping/ HPF Switch Bridge/Stereo Jumper C22 Controller Module Block Diagram SUB/LF Output High Freq High Pass Filter Delay Circuit Excur
45、sion Limiter Peak Limiter Peak Limiter Low Freq High Pass Filter Low Freq Low Pass Filter Thermal Limiter Diff.Amp Diff. Amp Thermal Limiter High Freq Low Pass Filter High Frequency EQ Low Frequency EQ Diff. Amp FR/HF Output To Ch. 1 Amp. To Ch. 2 Amp. Input Ch. 1 C12 Controller Module Block Diagram