《Qsc - Cm16Soft 电路图.pdf》由会员分享,可在线阅读,更多相关《Qsc - Cm16Soft 电路图.pdf(2页珍藏版)》请在收音机爱好者资料库上搜索。
1、QSControl Overview QSControl is a powerful and flexible system that provides remote management and diagnostics of QSC amplifiers and other audio devices over an Ethernet network.You can monitor and control hundreds of amplifiers simultaneously,as well as perform a wide range of advanced functions,su
2、ch as event logging and real-time monitoring of loudspeaker opens and shorts. A QSControl system is composed of System Controller (a Pentium-based PC) running QSControl Software that is linked via Ethernet to CM16a Amplifier Network Monitors or other net- worked audio devices.The CM16a provides sixt
3、een channels of remote gain adjustment and amplifier management for DataPort-equipped QSC amplifiers. QSControl Software QSControl Software allows you to view and adjust signal controls with the click of a mouse. You can use System Manager, a standard application included with QSControl Software, or
4、 design a custom application tailored to your specific needs with easy-to-use Visual Basic. QSControl Software Version 3.0 software significantly expands the systems overall capabilities. Users can now create custom applications with drag-and-drop programming, eliminating the need to write code. In
5、addition to amplifier management, users can now control additional audio components including MIDI devices.A QSControl system can now also be accessed and controlled by multiple System Controllers from multiple locations. The software also supports the new CM16a Amplifier Network Monitor,a 1-RU unit
6、 that links the PC to networked QSC amplifiers to provide remote control and monitoring functions. The new CM16a expands QSControls amplifier monitoring functions by allowing users to adjust thresholds for detecting load opens and shorts,monitor real-time load resistance,monitor amplifier output in
7、watts,and view amplifier headroom.The CM16a also supports QSCs new 4-channel amplifiers in addition to all DataPort- equipped QSC amplifiers.Users can also download future CM16a firmware updates quickly and easily from a remote PC via Ethernet. N E T W O R K A U D I O S Y S T E M SQSControl Software
8、 V.3.0 1675 MacArthur Boulevard Costa Mesa, CA 92626 Ph: 800/854-4079 or 714/957-7100 Fax: 714/754-6174 Web: Email: Hear the Power of Technology. QSControl 3.0s new and improved System Manager requires no programming to configure and control your system.Features include an Event Log for tracking sys
9、tem changes & status of amplifiers. Using Microsofts Visual Basic,custom screens and panels can be created to display and control all aspects of your system.Even control 3rd party gear over MIDI,RS-232,Ethernet,etc. RadioFans.CN 收音机爱 好者资料库 System Manager System Manager requires no programming whatso
10、ever to oper- ate the system.You can perform comprehensive signal metering and gain adjustment for each amplifier: Adjust input sensitivity for 3-volts or 1-volt Adjust input levels to the amplifier Meter pre-fader and post-fader levels Inverted the signal polarity Override each channel with an auxi
11、liary input that can be used for emergency paging. Fold back to audio to the front-of-house at three different points in the audio chain:pre-fader,post-fader,or the amplifier output. Up to sixteen configuration presets can be recalled automatically You can also perform comprehensive amplifier manage
12、ment: Monitor amplifier status including clip,protect,and operating temperature Monitor amplifier output including voltage, current, power in watts,and headroom Load status including load resistance and programmable thresholds for detecting loudspeaker opens and shorts Amplifier configuration includ
13、ing gain control settings and stereo,parallel,or bridge mode The amplifiers power status and AC standby mode System Manager also provides an Event Log that allows you to keep track of system events such as amplifier clipping, protect modes, loudspeaker opens and shorts, and other conditions. These t
14、ext files can be saved for future reference or downloaded remotely via modem. When any event occurs, System Manager automatically notifies you with a flashing icon. Custom Applications Operate QSControl with System Manager, our standard control application included with QSControl Software 3.0, or cr
15、eate a custom application to meet your specific needs.Using standard Windows tools like ActiveX , COM, and plug-in components for Microsoft Visual Basic, QSControl offers the most user-friendly and advanced development tools available today. QSControls open architecture also allows the control of ot
16、her manufacturers devices using RS-232, RS-485, MIDI, Ethernet, or other interfaces for a single integrated solution. Benefits of a Custom Application Build simple control screens that can perform complex functions. Create a full range of system-wide presets that are available for different operatin
17、g modes in multipurpose venues. Perform pre-programmed functions at designated times without an operator present.For example,perform basic diagnostic checks at night,log the results,and power the system down. Control non-QSC equipment via Ethernet,MIDI,contact closures, RS-232,RS-485 or other interf
18、aces for a single integrated solution. Automate performance monitoring and maintenance. For example, alert the operator whenever a loudspeaker circuit becomes open or shorted,mute the power amplifier,and log an error message for maintenance personnel. Provide a comprehensive set of fire and emergenc
19、y mode functions that are invoked by an external contact closure or other simple signal. Employ full,multi-level password security,allowing only authorized personnel access to certain control functions. What sets QSControl apart from other control systems? Ease of Customization QSControl uses Micros
20、ofts Visual Basic,the most popular application development tool for Microsoft Windows.Not only can you create a custom control application tailored to your exact requirements, but also can be done with simple drag-and-drop controls easy to understand commands. Dont have time build a custom applicati
21、on? No problemQSC technicians will create one for you to your specifications,or you can hire a qualified QSControl third-party developer. Ethernet Network The QSControl network uses standard off-the-shelf Ethernet hardware for its network. As the most widely used networking technology in the world,E
22、thernet is fast,reliable,low-cost,and is widely available. TCP/IP Communication Protocol QSControl uses TCP/IP,the same communications protocol used by millions worldwide to communicate on the Internet.This gives you the ability to interface with your existing LAN or WAN. After-sale Support QSC System Support is here for you 24hrs/7 days a week. Well help you setup your system,train your operators,and even work with you or a company of your choice to design custom control software. 042100 RadioFans.CN 收音机爱 好者资料库