《P2400, P2700 Owners Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《P2400, P2700 Owners Manual 电路图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、OPERATION MANUAL P2400 P2700 Dual Channel Power Amplifiers C12 C22 L20 Plug-In Controller Modules RadioFans.CN 收音机爱 好者资料库 2 P2400/P2700 OPERATION MANUAL Cautions WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE Explanation of Graphical Symbols The lightnin
2、g flash with arrowhead symbol, within an equilateral triangle, is intended to alert the use to the presence of uninsulated danger- ous Voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. The exclamanation point,within an equilat
3、eral triangle is intended to alert the users to the pres- ence of important operating and maintenance (servicing) instructions in the literature accom- panying the product. Erklrung der graphischen Symbole Der Blitz mit nach untenzielendem Pfeil in einem gleichseitigen Dreieck weist den Benutzer auf
4、 das Vorhandensein einer unisolierten, gefhrlichen Spannung im Gehuse hin, die stark genug sein kann, einer Person einen gefhrlichen elektrischen Schlag zu versetzen. Das Ausrufezeichen in einem gleichseitigen Dreieck weist den Benutzer auf wichtige Betriebs- und Wartungsvorschriften in den beiliege
5、nden Unterlagen des Gertes hin. WARNUNG: ZUR VERMEIDUNG VON FEUER ODER ELEKRISCHEN SCHLGEN DAS GERT NICHT MIT REGEN ODER FEUCHTIGKEIT IN BERHRUNG BRINGEN CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USER- SERVICEABLE PARTS INSI
6、DE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES NICHT FFNEN VORSICHT! UM DAS RISIKO EINES ELEKTRISCHEN SCHLAGES ZU VERMINDERN, ABDECKUNG NICHT ENTFERNEN. KEINE BENUTZER BEDIENUNGSTEILE IM INNERN. BEDIENUNG NUR DURCH QUALIFIZIERTES BEDIENUNGSPERSONAL. CA
7、UTION RISK OF ELECTRIC SHOCK: OPEN ONLY IF QUALIFIED AS SERVICE PERSONNEL VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES: NUR VON QUALIFIZIEREM WARTUNGSPERSONAL ZU FFNEN To reiterate the above warnings: servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perf
8、orm any servicing other than that con- tained in the Operation Instructions unless you are quali- fied to do so. Refer all servicing to qualified personnel. Eindrigliche Warnung: Wartungsvorschriften dienen nur der Benutzung durch qualifizieres Personal. Zur Vermeidung eines elektrischen Schlages ke
9、ine anderen als die in den Betriebsvorschriften beschriebenen Wartungsarbeiten ausfhren, es sei denn Sie sind dafr qualifiziert. Wartungsarbeiten sind nur von qualifiziertem Wartungspersonal auszufhren. CAUTION TO AVOID ELECTRIC SHOCK, DO NOT INSERT FINGERS OR OBJECTS INTO ANY OPENINGS IN THE CABINE
10、T VORSICHT UM ELEKTRISCHEN SCHLAG ZU VERMEIDEN, KEINE FINGER ODER GEGENSTNDE IN FFNUNNGEN DES GEHUSES STECKENN Sicherheitsvorschriften RadioFans.CN 收音机爱 好者资料库 3 P2400/P2700 OPERATION MANUAL Table of Contents Warning Messages2 Table of Contents3 Introduction4 Technical Specifications5 Front Panel Fea
11、tures Status LEDs6-7 Signal LEDs6-7 Output Attenuators6-7 On/Off Switch7 Rear Panel Features AC Fuse8 Output Connections8 Standard Input Module Output Mode Selector8 Input Connections9 Looping Outputs9 Ground Lift Switch9 Loudspeaker Controller Modules C12 Loudspeaker Controller Module10 Input Conne
12、ctions10 Output Connections10 C22 Loudspeaker Controller Module10 Output Connections10-11 Input Connections11 Ground Lift Switch11 C22 Setup Switches12 L20 Limiter Module Looping Outputs12 HPF Selectors12 Input Connectors12 Limit Set Switches12 Output Mode Selector13 Ground Lift Switch13 Amplifier S
13、et-Up and Operation14 Cooling14 Mounting14 Wire Size14 Performance Verification14 System Block Diagrams Without Controller Modules15 With L20 Limiter Module15 With C12 Controller Module16 With C22 Controller Module16 4 P2400/P2700 OPERATION MANUAL Congratulations on your purchase of a Renkus-Heinz P
14、2400 or P2700 dual-channel, professional, power amplifier. Your Renkus-Heinz amplifier has been designed to provide years of trouble-free, high performance operation. We hope you enjoy it. Your amplifier may include a C12 or C22 loudspeaker controller module or a L20 Limiter Module in place of the s
15、tandard dual channel input module (see pages 8 to 13 for details). The C12 and C22 controller modules are dedicated companions to a specific Renkus-Heinz loudspeaker. They provide protection circuitry, electronic crossover circuitry and response optimization for their associated loudspeakers. The L2
16、0 is a limiter module with user adjustable limit and HPF controls. It is not loudspeaker specific and allows the user to adjust the controls to suit his applica- tion. Caution: If your amplifier includes a C12 or C22, it is configured for use with a particular loudspeaker model and should not be use
17、d with any other model. Use of the wrong loudspeaker may result in loudspeaker damage. Your Renkus-Heinz amplifier was completely tested and inspected before leaving our factory and should have arrived in perfect condition. Please carefully inspect your amplifier and its shipping carton for any noti
18、ceable damage, and if any damage is found, immediately notify the shipping company. Only the consignee may institute a claim with the carrier for any damage incurred during shipping. Be sure to save the carton and all packing materials for the carriers inspection. It is also a good idea to save the
19、carton and packing material even though the ampli- fier arrived in good condition. If shipping the amplifer should ever be required, it should be shipped only in its original factory packing. Important: Your Renkus-Heinz amplifier contains no user-serviceable parts and all service should be referred
20、 to qualified service personnel. We recommend that it be returned to the factory in its original packing carton if factory service is required. Introduction 5 P2400/P2700 OPERATION MANUAL Technical Specifications POWER OUTPUT RATINGS: (20HZ to 20 kHz 0.1% THD) FREQUENCY RESPONSE: THD (at 1kHz) DISTO
21、RTION: SMPTE IMD: HUM P2700 - 1500 VA) Temperature, DC output, short circuit protection Delayed turn-on with output muting Subsonic and ultrasonic filters Signal 3/16 aluminum face panel Black (powder coat) Output level attenuators, power on/off, Stereo/mono/bridging mode selector Ground lift switch
22、 Inputs; 3-pin female XLR ( pin 2 +) Outputs; 4-pin Neutrik Speakon Looping (controller) output(s); 3-pin male XLR (pin 2 +) 3 1/2 H x 19 W x 18 D ( depth behind panel) (8.9 x 48.2 x 45.7 cm) (P2400) 32.1 lbs (14.6 kg) (P2700) 35 Lbs (15.9 kg) C12 setting the attenuators at a lower level maximizes t
23、he system signal/noise ratio. Important - - When the amplifier is being operated in the bridge output mode, both the Channel 1 and Channel 2 attenuators must be set in the same position to avoid a mismatch in the signal level being sent to each channel. Output Attenuator 010 CHANNEL 1 STEREO POWER A
24、MPLIFIER SIGPWR PROTCLIP G R 231 7 P2400/P2700 OPERATION MANUAL Front Panel Features On/Off Switch 4. Channel 2 Status (Prot/Pwr) LED The Channel 2 Status LED glows green to indicate the amplifier is on and Channel 2 is operating normally. It glows red to indicate that one or more of the amplifiers
25、Channel 2 protective circuits has been activated. The amplifier contains separate over-temperature, DC on output and shorted- load protective circuitry for each channel. Whenever a fault is detected in Channel 2, the channel is temporarily shut down and the status light turned red to call attention
26、to the problem. The channel will remain off until normal operating conditions are restored. Note. The status LED is also controlled by the C12 setting the attenuators at a lower level maximizes the system signal/noise ratio. 7. Power On/Off Switch This switch is used to turn power to the amplifier o
27、n and off. Signal LEDs Status LEDs Output Attenuator POWER MODEL P2400 7 SIGPWR PROTCLIP G R 010 CHANNEL 2 456 8 P2400/P2700 OPERATION MANUAL 1. AC Power Cord on the P2700 a T 16 A, 250 V. Before connecting the amplifier, check the AC voltage requirement and make certain the unit is connected to the
28、 proper voltage. Failure of the unit will result if a 120 volt amplifier is connected to a 220 volt power line. 2. Channel 2 Output Connector 4-Pin Neutrik Speakon connector provides single-connector, quick-disconnect facilities for Channel 2 on pins 1+ used to drive addi- tional amplifiers. 3. FR/H
29、F Output Connector Male 3-pin XLR type controller output connector for the FR/HF channel; used to drive additional amplifiers. Note: When the processed controller outputs are used to drive additional amplifiers, it is imperative that the source amplifiers level controls are set at the same or a high
30、er level. Other- wise, the protection feature is lost for the other amplifiers. The C22 loudspeaker controller module is a dual input, dual output controller designed for use in stereo systems having either passive loudspeakers or subwoofers. In these systems, it provides protection for the loudspea
31、kers or subs, as well as high provides a loop- ing controller processed output for use in driving additional amplifiers. 3. Channel 2 FR/HPF Output Connector Male 3-pin XLR type controller output connector for the FR/HPF channel; used to drive addi- tional amplifiers. An internal selector switch det
32、ermines whether this connector provides a full- C12 Controller Module Input Connections Output Connections cc PIN 1 = GND PIN 2 = + PIN 3 = - MODEL C12 SUB/LF OUT FR/HFINPUT RENKUS-HEINZ MADE IN USA 1 32 Loudspeaker Controller Modules Output Connections 11 P2400/P2700 OPERATION MANUAL range looping
33、output or a processed band-limited high pass filter output. Refer to Selector Switches on page 12 for further information. 3. Channel 2 Audio Input Connector Female 3-pin XLR type input connector. The input is electronically balanced. We recommend the use of pin 2 as hot and pin 3 as neutral. Pin 1
34、is chassis ground. When the amplifier is connected to a balanced source, the shield may either be lifted or connected at the source end. The choice should be made on the basis of minimum hum. With an unbalanced source, connect the signal to pin 2 and source ground to pin 3 (connecting the signal to
35、pin 3 is not rcommended as this will cause a 180 phase inversion at the amplifier outputs). Note: Improper operation results when only pin 2 or only pin 3 and pin 1 (ground) are used for an unbalanced input. 4. Ground Lift Switch. The Ground Lift switch is used to separate the signal ground circuit
36、from the amplifier ground circuit and thus, eliminate hum induced by ground loops. In the right position, the input signal ground is electrically connected to the amplifier ground circuit (the chassis). In the left position, only an AC connection is provided between the signal ground and the amplifi
37、er ground circuit (the chassis). 5. Channel 1 Audio Input Connector. Female 3-pin XLR type input connector for Channel 1. Refer to 3 above for details. 6. Channel 1 FR/HPF Output Connector Male 3-pin XLR type controller output connector for the FR/HPF channel; used to drive addi- tional amplifiers.
38、An internal selector switch determines whether this connector provides a full- range looping output or a processed band-limited high pass filter output. Refer to Selector Switches on page 12 for further information. 7. Channel 1 Processed Output Connector Male 3-pin XLR type controller processed out
39、put connector for Channel 2; provides a loop- ing controller processed output for use in driving additional amplifiers. Note: When the processed controller outputs are used to drive additional amplifiers, it is imperative that the source amplifiers level controls are set at the same or a higher leve
40、l. Other- wise, the protection feature is lost for the other amplifiers. Input Connections Input Connections Ground Lift Switch Loudspeaker Controller Modules Output Connections GROUND LOOPING / HPF PIN 1 = GND PIN 2 = + PIN 3 = - CH 2 OUTPUTS MODEL C22 PROCESSEDLOOPING / HPF CH 1 INPUTCH 2 INPUT RE
41、NKUS-HEINZ MADE IN USA CH 1 OUTPUTS 1325674 PROCESSED 12 P2400/P2700 OPERATION MANUAL The C22 Loudspeaker Controller Module has several selector switches and a Stereo/Bridging Jumper plug that are accessible by removing the module from the amplifier. The location of these controls is shown in the ab
42、ove outline drawing. The Looping/HPF switches control the signals to the Looping/HPF output connectors. In the Filtered position, the associated output connector is connected to the output of that channels high pass filter. In the other position, the connector parallels that channels input connector
43、 and servers as a looping output. The HPF setting is used to deliver a band-limited signal to an additional amplifier for non-overlap operation (refer to the system wiring diagram on page 16 for further information). The Stereo/Bridging Jumper plug is used to bridge the two output channels together
44、to provide a single output with twice the power capabilities of a single channel. Note that the Jumper Plug is located under the right PK22-xxx kit, which must be removed (unplugged) to gain access to the Jumper Plug. The switches identified as sw 1, sw 2 and sw 3 are used to configure the C22 for s
45、pecific loudspeakers. Additional information on these switches can be found in the C22 Operation Manual. The L20 is a dual-channel limiter module. It is not loudspeaker specific and is provided with user adjustable limit and HPF (high pass filter) controls (refer to drawing on next page). It is used
46、 to provide limiting on both amplifier channels (loudspeaker protection) plus low frequency rolloff. 1 & 6. Looping Audio Output Connectors These male 3-pin XLR type connectors are wired in parallel with the input connectors and provide unprocessed looping Channels 1 and 2 outputs. They allow loopin
47、g through to additional amplifiers. 2 & 5. HPF Selector Switches Three position switches allow the Channel 1 and 2 low frequency rolloff points to be set at either 30 Hz, 60 Hz or 100 Hz to protect small loudspeakers from over excursion damage. C22 Setup Switches HPF Selectors Looping Outputs L20 Li
48、miter Module Filtered Filtered Stereo Bridged Stereo/Bridged Jumper Plug Looping/HPF Selector Switches sw 3sw 3 sw 2 sw 2 sw 1 sw 1 PK22-xxx KitPK22-xxx Kit C22 Controller Module Physical Layout Loudspeaker Controller Modules 13 P2400/P2700 OPERATION MANUAL 3 & 4. Audio Input Connectors Female 3-pin
49、 XLR type input connectors for Channels 1 and 2. Refer to section 6 on page 9 for wiring details. 7 & 10. Limit Set Switches Three position switches allow the Channel 1 and 2 maximum output levels to be set at either 100, 200 or 350 watts into 8 ohms (400, 800 or 1400 watts in bridge mode). 8. Stereo - Parallel - Bridge Output Mode Selector The Output Mode Selector allows the amplifer to be operated in 3 different output modes. In the Stereo mode, the two channels operate independently, just as they do in a stereo amplifier: signals fed