1、1 Ver. 1.3 2005.03 SERVICE MANUALUS Model AEP Model UK Model ICD-P110/P210 Canadian Model E Model Chinese Model Tourist Model ICD-P210 ICD-P110/P210 Recording mediaBuilt-in flash memory 16MB (ICD-P110)/ 32MB (ICD-P210), Monaural recording Recording timeICD-P110: HQ: 1 hour 40 minutes SP : 4 hours 35

2、 minutes LP : 7 hours 35 minutes ICD-P210: HQ: 3 hours 35 minutes SP : 9 hours 40 minutes LP : 15 hours 45 minutes Frequency rangeHQ: 250 Hz 6,800 Hz SP/LP: 220 Hz 3,400 Hz Speakerapprox. 2.0 cm (13/16 in.) dia. Power output250 mW Input/Output Earphone jack (minijack) for 8 300 ohms ear receiver/hea

3、dphones Microphone jack (minijack, monaural) Plug in power Minimum input level 0.6 mV 3 kilohms or lower impedance microphone USB connector Sony Corporation Personal Audio Group Published by Sony Engineering Corporation IC RECORDER Photo: ICD-P110 Power requirementsTwo LR03 (size AAA) alkaline batte

4、ries: 3 V DC Dimensions (w/h/d) (not incl. projecting parts and controls) 30.0 103.5 16.0 mm (1 3/16 4 1/8 21/32 in.) Mass (incl. batteries)60 g (2.1 oz) Supplied accessoriesOperating instructions (For the IC recorder (1)/ For the application software (1)/LR03 (size AAA) alkaline batteries (2) (For

5、the US and UK only)/USB connecting cable (1) Application software (CD-ROM) (1) Carrying pouch (1) (For Chinese and Korea only) Receiver MDR-E0110LP/BC (1) (For Chinese and Korea only) Design and specifications are subject to change without notice. SPECIFICATIONS 9-879-330-04 2005C04-1 2005.03 RadioF

6、ans.CN 收音机爱 好者资料库 2 ICD-P110/P210 Notes on Chip Component Replacement Never reuse a disconnected chip component. Notice that the minus side of a tantalum capacitor may be damaged by heat. z UNLEADED SOLDER Boards requiring use of unleaded solder are printed with the lead free mark (LF) indicating th

7、e solder contains no lead. (Caution: Some printed circuit boards may not come printed with the lead free mark due to their particular size) : LEAD FREE MARK Unleaded solder has the following characteristics. Unleaded solder melts at a temperature about 40 C higher than ordinary solder. Ordinary sold

8、ering irons can be used but the iron tip has to be applied to the solder joint for a slightly longer time. Soldering irons using a temperature regulator should be set to about 350 C. Caution: The printed pattern (copper foil) may peel away if the heated tip is applied for too long, so be careful! St

9、rong viscosity Unleaded solder is more viscou-s (sticky, less prone to flow) than ordinary solder so use caution not to let solder bridges occur such as on IC pins, etc. Usable with ordinary solder It is best to use only unleaded solder but unleaded solder may also be added to ordinary solder. TABLE

10、 OF CONTENTS 1.SERVICE NOTE.3 2.GENERAL.4 3.DISASSEMBLY 3-1.Case (Front) Assy .5 3-2.SW Board, MAIN Board.6 3-3.AUDIO Board.6 4.SERVICE MODE.7 5.DIAGRAMS 5-1.Block Diagram . 15 5-2.Printed Wiring Board AUDIO Section . 17 5-3.Schematic Diagram AUDIO Section . 18 5-4.Printed Wiring Board MAIN Section

11、. 19 5-5.Printed Wiring Board SW Section . 20 5-6.Schematic Diagram MAIN/SW Section . 21 6.EXPLODED VIEWS 6-1.Case (Front) Section . 25 6-2.Case (Rear) Section . 26 7.ELECTRICAL PARTS LIST. 27 RadioFans.CN 收音机爱 好者资料库 3 ICD-P110/P210 SECTION 1 SERVICE NOTE 1-1.CAUTIONS OF FLASH MEMORY (IC701) EXCHANG

12、E Precaution When the Flash Memory (IC701) is Replaced When the flash memory (IC701) is replaced, be sure to perform the BAD BLOCK check* and writing of the model code. If they are not completed, the unit will not operate normally. * BAD BLOCK check is to check the flash ROM memory area (the BAD BLO

13、CK area) where data cannot be guaranteed. The resultant information of this check is stored in the TOC- AREA so that the BAD BLOCK area should not be used. BAD BLOCK Check Procedure 1.When the power is turned on after the flash memory (IC701) is replaced, the BAD BLOCK check starts automatically and

14、 the OPR (D701) lights in orange. 2.In about 30 seconds after start of the check, the OPR (D701) changes the color to green indicating that the check is completed. 1-2.NOTES FOR REPLACEMENT OF THE MICROCOMPUTER (IC702) The IC702 on the MAIN board has former and new types of models. Former type : MB9

15、1F233LLGA-GE1 (flash microcomputer) New type: MB91233LLGA-G-107E1 (mask microcomputer) The service parts include only new types of models. When replacing the IC702, check the model number. The transistors Q706 and Q707 for program write should be removed when the previous type is installed. MAIN BOA

16、RD (SIDE B) TP721 D701 D701 OPR (PB) (REC) G R TP718 TP726TP725 1 2 3 1 R730 C708 ET701 Q704 R728 R758 C729 C730 IC706 1-865-058- 11 (11) RadioFans.CN 收音机爱 好者资料库 4 ICD-P110/P210 SECTION 2 GENERAL This section is extracted from instruction manual. Index to Parts and Controls Main unit MIC (built-in m

17、icrophone) Display window MENU DISPLAY zXREC (record) /PAUSE NxPLAY/STOP (ENTER) .(review/fast backward)/ + (cue/fast forward) (SELECT) Speaker Rear Hook for handstrap (not supplied) MIC SENS (microphone sensitivity) USB connector Battery compartment Display window Folder indication Alarm indicator

18、Repeat play indicator Selected message number REC DATE (recorded date) indication REMAIN indicator MIC jack (PLUG IN POWER) EAR (earphone) jack OPR (operation) indicator ERASE FOLDER VOL (volume) +/ DIVIDE HOLD xSTOP Remaining memory indicator Remaining battery indicator Recording mode indication RE

19、C (recording) indication EASY-S (easy search) indictaion Number of messages in a folder/Menu indication/Counter /Remaining time indication / Recording date indication /Current time indication / Messages 5 ICD-P110/P210 SECTION 3 DISASSEMBLY This set can be disassembled in the order shown below. Note

20、: Follow the disassembly procedure in the numerical order given. 3-1.CASE (FRONT) ASSY 3-1. CASE (FRONT) ASSY (Page 5) 3-2. SW BOARD, MAIN BOARD (Page 6) SET 3-3. AUDIO BOARD (Page 6) 1battery case lid 2screw 3screw 4claw 5two claws 6two claws 7case (front) assy 6 ICD-P110/P210 3-2.SW BOARD, MAIN BO

21、ARD 3-3.AUDIO BOARD 2SW board 6MAIN board 4lid (connector) 1CN705 5CN701 3 S701 0AUDIO board S702 1screw 2speaker 3 4 6 8 9 5claw 7claw 7 ICD-P110/P210 4-1.SETTING METHOD OF THE SERVICE MODE To enter the service mode, turn on the HOLD switch while pressing the x STOP key and VOL key at the same time

22、 with the power on. 4-2.EXITING METHOD OF THE SERVICE MODE Exit the service mode by turning off the power. 4-3.CONTROL OPERATIONS AND DISPLAYS 4-3-1. Layers The service mode has a maximum of three layers according to the mode items: Layer for item selection Layer for operation selection Layer for op

23、erating state or test result display To switch to another layer in a certain layer, basically Bx key switches to another layer and x STOP key returns to the previous layer. To select the next item/operation in a layer, the key is used. To select the previous item/operation, the . key is used. When t

24、he items are circulated by selecting them, the first item is displayed. B.0201 E P20 Destination information Model information CPU FW information In this case, B1.02. SECTION 4 SERVICE MODE 8 ICD-P110/P210 10. USB11. KEY Proof-Test12. MENU Resetting Set Specification MENU BLCDAUdIO.0201 E P20 SLEEP

25、BEEP RTC KEY USB KEY COUNTMENU BATTLED . . . . . . . . . . . . . 1. Set Specification 4. SLEEP 7. A/D KEY Voltage8. BATTERY Voltage9. LED Lighting 5. BEEP Sounding6. RTC Connection and Operation 2. LCD3. AUDIO Block Operation 4-3-2. Control Operations for Item Selection These control operations are

26、used to select the following items. However, “Set Specification” has no more layers since all is displayed in the layer. 9 ICD-P110/P210 2. LCD segment connection This mode checks the LCD Common/Segment connections. There are two displays: All LCDs ON and All LCDs OFF. LCD . LCD ALL LCD OFF xx x BxB

27、x Bx Item selection displayOperation selection displayOperating state display Operation selection displayOperating state display ALL LCDs ON ALL LCDs OFF (Lighting) STOPSTOP STOP 4-3-3. Control and Display Specification for Each Service Mode 1. Set specification This mode checks the destination, mod

28、el, CPU version and has no layers. B.0201 E P20 Destination information Model information CPU FW information In this case, B1.02. 10 ICD-P110/P210 3. AUDIO block operation This mode tests the AUDIO circuit by DSP LOOP operation. When earphone is not inserted into earphone jack, SP-AMP is turned ON.

29、When it is inserted into earphone jack, SP-AMP is OFF and HP- AMP is ON. Pressing of the ERASE key turns MUTING ON or OFF. Pressing of the VOL + key or VOL key allows the volume value to be controlled. The MIC sensitivity can be changed LOW or HIGH by operating the MIC SENS switch. There is no displ

30、ay. The VOR threshold level is shown by the red LED indicator that lights with AUDIO present. AUdIOMONO MONOMONO MONO OFF 10 HQHQ MONO ON 10 HQ SPSP LP LP BxBx . . OFF MONOMONO OFF Bx Bx xx x x Item selection displayOperation selection display Flashing HQ DSP LOOP SP DSP LOOP LP DSP LOOP VOLUME valu

31、e MUTE status Operating state display Operation selection displayOperating state display Operation selection displayOperating state display Display when MUTING is ON. The VOR threshold level during operating state is checked by the red LED indicator. ON:Audio present OFF: No Audio STOPSTOP STOP STOP

32、 ERASE 11 ICD-P110/P210 4. SLEEP test In this mode, the waiting current and the WAKE UP circuit can be checked during SLEEP mode. This SLEEP test is executed about 1 second after the Bx key is pressed. There is no operation selection display. The display depends on whether the HOLD switch is ON or O

33、FF. HOLD SW OFF: OK SLEEP HOLD SW ON: All display OFF A WAKE UP operation such as any key stroke during SLEEP returns to the layer for item selection. SLEEP SOONSLEEP OK Bx Bx Bx x Item selection display When HOLD is OFF: When HOLD is ON: Operating state display During SLEEP Operating state display

34、During SLEEP Operating state display 1second before SLEEP STOP 5. BEEP sounding This mode cause 1.3 kHz and 2 kHz beeps to sound. The P-AMP operation is based on the earphone jack specification. BEEP OFF . Bx 1 . 3k ON 1 . 3k Bx OFF 2 . 0k2 . 0k ON Bx xx x Item selection display 1.3kHz Beep sounds.

35、2kHz Beep sounds. Operating state displayOperation selection display Operating state displayOperation selection display STOPSTOP STOP 12 ICD-P110/P210 6. RTC connection and operation This mode provides self-check of the RTC connection and operation. It includes three checks: RTC connection check, da

36、ta write and read check, and XRTCINTR (interrupt signal) check. There is no layer (display) for operation selection. Result of this check is shown as “OK” or “BAD”. RTCRTC OK RTC BAD Bx x Item selection displayResult display Result display Check OK Check NG STOP 7. A/D KEY voltage This mode displays

37、 the CPU input voltages of KEYIN0 and KEYIN1 in hexadecimal (HEX) format. Pressing of a specific key causes the corresponding voltage to be displayed. In this mode, the x STOP key will display the corresponding voltage while it is being pressed. The display will be returned to the layer for item sel

38、ection by releasing the x STOP key. There is no layer (display) for operation selection. KEY KEY A8 FF Bx x Item selection displayResult display Voltage of KEYIN0 Voltage of KEYIN1 STOP 8. BATTERY/DC-IN CPU input detection voltage This mode displays the CPU input voltage of either BATTERY or DC-IN i

39、n hexadecimal (HEX) format. A battery full mark is shown during BATTERY operation and this mark is extinguished during DC-IN operation. There is no layer (display) for operation selection. BATTBATT E8 Bx x Item selection displayResult display Voltage BATTERY : FULL mark DC-IN : No display STOP 13 IC

40、D-P110/P210 9. LED lighting This mode causes LEDs to light for checking. The red and green LEDs are controlled at the same time. 10. USB test This mode provides VBUS ON/OFF display and SUSPEND test. There is no layer (display) for operation selection. The Bx key displays the VBUS status as “ON” or “

41、OFF”. With VBUS ON, turning the HOLD switch ON causes SUSPEND mode to be performed. VBUS TEST Bx LEDLED ON x Item selection display LED: OFFON Result display STOP SUSPEND TEST With VBUS ON, turning the HOLD switch ON causes SUSPEND mode to be performed. To cancel this mode, switch VBUS to OFF. Bx US

42、BBUSV ON BUSV OFF x Item selection displayResult display VBUS present No VBUS Result display STOP Bx HOLD ON VBUS-OFF USBBUSV ON SUSPE x Item selection display VBUS present Result display STOP 14 ICD-P110/P210 11. KEY proof-test In this mode, counts are displayed by pressing a specific key. It is po

43、ssible to check how many times the key is pressed for KEY proof-test. Keys to be tested include slide switches (HOLD and MIC SENS). Counts are displayed to the upper limit of “999999” in decimal format. However, the value will not be reset in this mode. To exit from this mode, the power should be tu

44、rned off. KEY COUNT KEYKEY - - - -000000 BxBx Item selection display The counter is incremented each time a key is pressed. 12. MENU and FLASH MEMORY contents resetting This mode initializes MENU information (including clock to be set) and all erases all the folders. In order to complete this test,

45、all the keys and all the slide switches must bee operated. In control of keys and slide switches, their names a displayed. The WAKE UP signal is also checked for tact keys. If any key or switch names are not displayed, the controls are faulty. To exit from this mode, the power should be turned off.

46、MENUPUSH KEY PLAY OK PLAY OK BxBx ALL OK Bx Item selection display Operating state display Operating state display HOLD switch:ON/OFF MIC SENS switch:HI/LO DISPLAY key:DISP VOL+ key:+ VOL VOL key:- VOL FOLDER key:FOL ERASE key:ERASE DIVIDE key:DIVIDE STOP key:STOP PLAY/STOP key:PLAY . key:FR key:FF

47、REC/PAUSE key:REC MENU key:MENU HOLD switch:HOLD MIC SENS switch:MIC 1515 ICD-P110/P210 ICD-P110/P210 5-1.BLOCK DIAGRAM SECTION 5 DIAGRAMS 47 MIP LOUT0 23 EGPI011 EGPI014 EGPI013 EGPI015 BGPI02 EGPI012 RSTN 2651 XOUT 52 34 XIN 25 27 58 24 54 Q506 +3V(VDD) MIC101 MIC MIC SENS LOW HIGH J101 MIC (PLUG IN POWER) J103 EAR IC102 A/D,D/A CONVERTER, DSP IC702 SYSTEM CONTROL, LCD DRIVER X101 4.096MHz 4 8 5 1 3 2 -IN +IN BYPASS VO1 VO2 SP1 SPEAKER IC103 POWER A