《Sony-CDPM555ES-cd-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Sony-CDPM555ES-cd-sm 电路图 维修手册.pdf(21页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COMPACT DISC PLAYER US Model Canadian Model SPECIFICATIONS CDP-M333ES/M555ES Photo: CDP-M555ES Model Name Using Similar MechanismNEW CD Mechanism TypeCDM62-K1BD35B Base Unit NameBU-K1BD35B Optical Pick-up NameKSM-213BFN/C2NP RadioFans.CN 收音机爱 好者资料库 4 CD-TEXT TEST DISC This unit is abl
2、e to display the TEXT data (character information) written in the CD on its fluorescent indicator tube. The CD-TEXT TEST DISC (TGCS-313:J-2501-126-A) is used for checking the display. To check, perform the following procedure. Checking Method: 1.Turn ON the power, set the disc on the disc table with
3、 the side labeled as “test disc” as the right side, close the front cover, and chuck the disc. 2.The following will be displayed on the fluorescent indicator tube. (The display switches each time the SCROOL button is pressed.) Display: CD TEXT TEST DISC (Album Title) 3.Press theHbutton and play back
4、 the disc. 4.The following will be displayed on the fluorescent indicator tube. (If nothing is displayed, press the SCROOL button.) Display: 1 kHz/0 dB/ L ?(38h to 3Fh) A B C D E F G (40h to 47h) H I J K L M N O (48h to 4Fh) P Q R S T U V W (50h to 57h) X Y Z _(58h to 5Fh) a b c d e f g(60h to 67h)
5、h ij k l m n o(68h to 6Fh) p q r s t u v w(70h to 77h) x y z I (78h to 7Fh) i (A0h to A7h) 8859-1 9 C PR (A8h to AFh) 23 (B0h to B7h) 1 (B8h to BFh) (C0h to C7h) (C8h to CFh) D (D0h to D7h) Y(D8h to DFh) (E0h to E7h) (E8h to FFh) (F0h to F7h) y(F8h to FFh) No.66 No.67 to No.99 113 424 Displayed Cont
6、ents T All the same T All the same T All the same T All the same T All the same T All the same T All the same X Y Z _(58 T All the same T All the same T All the same x y z I (78 i (A0 is not displayed 9(A8 C PR are not displayed (B0 23 are not displayed (B8 1 are not displayed T All the same T All t
7、he same T All the same Y(D8 T All the same T All the same o (F0 T All the same T All the same T All the same to T All the same 113 424 Table 2: CD-TEXT TEST DISC Recorded Contents and Display (In this unit, some special characters cannot be displayed. This is no a fault.) RadioFans.CN 收音机爱 好者资料库 6 A
8、LIGNMENT OF GEAR (CAM) PHASE WITH DOOR ASSY CLEANING OF OPTICAL PICK-UP door assy gear (cam) Align a slit of door assy with a marking on the bottom land of gear tooth when the gear is rotated fully in arrow direction, as shown. optical pick-up magnet assy Remove the magnet assy, and clean the lens o
9、f optical pick-up through this hole. 12 r 1.Disc change 2.Load in 3.TOC read 4.Access of last track 5.3 second playback 6.Access of first track 7.3 second playback 8.Load out 1.No. 80 2.No. 320 3.No. 240 4.No. 400 5.No. 160 Sequence of Aging ModeOrder of Disc Change (1 cycle takes 3 minutes) AGING M
10、ODE Mode which repeatedly changes and plays back discs automati- cally in the unit. It will repeat aging as long as no errors occur. If an error occurs during aging, it will stop all servos, motors, etc. instantaneously, display the error number, and stop opera- tions. However, the stopping conditio
11、ns differ according to whether the unit is equipped with the “self-protection function during errors” described later. The function serves to maintain the state of the unit when errors occur. SECTION 4 SERVICE MODE SPECIAL FUNCTION This unit is provided with several service modes. Details are shown
12、in the following table. Turn on the power and press GROUP FILE , MEGA CTRL and I/1 buttons. Rotate the DISC/CHARACTER knob to enter any of the following modes. To exit the mode, press I/1 button to enter the standby state. (When selecting the Ship mode, the standby mode is automatically entered.) Co
13、ntents Mechanism adjustment mode Mode in which table keeps rotating All lights ON mode Default mode Normal aging mode Table aging mode Door/popup aging mode Color bar on OSD Test display for OSD Memo copy mode Model name display Software version display 400-memo writing mode Bus check Loading aging
14、Display Mech Adjust Table Roatation All Lit Mode Ship Mode Normal Aging Table Aging Door Popup Aging Color Bar (OSD) Test Disp (OSD) Memo Copy Mode Model Name Show Mcom Ver. Demo BUS Check M kentou r r r r r r r r r r r r r r 13 AGING PROCEDURE 1.Turn on the power and press the GROUP FILE , MEGA CTR
15、L and I/1 buttons. 2.Rotate DISC/CHARACTER knob, select “Normal Aging” and press the button to start the aging mode. 3.When the disc set mode is set, the H and X LEDs blink. 4.Rotate the DISC/CHARACTER knob. The slits (No. 80, 160, 400, 240, 320) for setting the discs will come forward. Insert the d
16、iscs into these slits. Do not set the discs in other slits. 5.Set whether the self-protection function during errors is equipped with the unit. Press the REPEAT button. If “REPEAT” is displayed on the fluorescent indicator tube, it means the function is provided. If “REPEAT” is not displayed, it mea
17、ns the function is not provided. 6.Press the H button. 7.The H LED blinks, the aging mode is set, and aging is started. 8.The aging cycle lasts 3 minutes. If errors occur during aging, the error number will be displayed on the fluorescent indicator tube. (Refer to the following table for the details
18、 of the errors.) 9.Aging will be repeated as long as no errors occur. 10. After each aging cycle, the number displayed on the Fluorescent indicator tube will increase. 11. To end aging, to end aging, press the I/1 button to enter the standby mode. ContentsCode numberName Error code The * numbers mea
19、n the following according to the state of the unit during aging 2 : From chucking to end of TOC read 3 : From end of TOC read to end of last track playback 4 : From end of last track playback to end of first track playback # : DISC No. SPECIAL AGING MODE FUNCTIONS The aging mode is provided with the
20、 following convenient func- tions Disc setting mode (*1) Selection of presence of protection function during error (*2) Count function of aging cycle (*3) *1Disc setting mode: 5 discs are set before setting the aging mode. This mode makes the setting of these discs more easy. *2Self protection funct
21、ion during errors: Function which voluntarily corrects errors which occur during normal operations by retries. If this function is not provided, all operations will be stopped without retiring. It is suitable for checking errors with low reproducibility. If this function is provided, and errors can
22、be corrected by retries, aging will be continued without stopping. *3Aging cycle count function: Functions which displays the number of agings carried out on the Fluorescent indicator tube in numbers. One aging cycle consists of five discs. #Err 01 #Err 02 #Err 03 #Err 04 #Err 05 #Err 06 #Err 08 #Er
23、r 09 #Err *1 #Err *2 #Err *3 #Err *4 #Err *5 #Err *6 DISC sensor check 1 DISC sensor check 2 Table operation check 1 Table operation check 2 Loading operation check 1 Loading operation check 2 Table stop precision check 1 Table stop precision check 2 BU related check 1 BU related check 2 BU related
24、check 3 BU related check 4 BU related check 5 BU related check 6 No disc in the specified slit Disc in other slits Table motor current over No table sensor input Load in timeover Load out timeover Table is not stopped within the specified time. Stopped while both T.SENS 1 and 2 are “LOW”. Access tim
25、eover During high speed playback, COUNT timeout Q data read error BU operation (from focus search to until signal can be read) timeover GFS monitor error Focus cannot be imposed by focus search 14 for checking the microprocessor model setting, etc. Procedure: With the power ON, while pressing the GR
26、OUP FILE and MEGA CTRL buttons, press the I/1 button. Rotate the DISC/CHARACTER knob, select “Model Name” and press the dial. The model name is displayed on the fluorescent indicator tube. Let the model name be displayed for three seconds and exit the mode. MICROPROCESSOR VERSION DISPLAY The micropr
27、ocessor version can be displayed on the fluorescent indicator tube. Procedure: With the power ON, while pressing the GROUP FILE and MEGA CTRL buttons, press the I/1 button. Rotate the DISC/CHARACTER knob, select “Show Mcom Ver.” and press the dial. The microprocessor version is displayed on the fluo
28、rescent indi- cator tube. Let the model name be displayed for three seconds and exit the mode. LOADING AGING MODE This mode is used for repeating loading operations continuously. Aging will be performed continuously unless an error occurs. When an error occurs, the error code will be displayed on th
29、e fluorescent indicator tube. Procedure: 1.Set a disc in the DISC 1 slit. 2.Turn on the power and press the GROUP FILE , MEGA CTRL and I/1 buttons. Rotate the DISC/CHARACTER knob, select “Table Roatation” and press the dial. 3.When the mode is set, both the H and X indicators will start to blink. 4.
30、When the H button is pressed, only the H indicator will blink and aging starts. 5.To end the mode, press the I/1 button or disconnect the power cord from the outlet. The error codes displayed during operations and when errors oc- cur are the same as the “AGING MODE” described earlier. TABLE AGING MO
31、DE This mode is used for rotating the table randomly. Aging will be performed continuously unless an error occurs. When an error occurs, the error code will be displayed on the fluorescent indicator tube. Procedure: 1.Turn on the power and press the GROUP FILE , MEGA CTRL and I/1 buttons. Rotate the
32、 DISC/CHARACTER knob, select “Table Aging” and press the dial. Rotate the DISC/CHARACTER knob and set the disk in the slit whose number is being displayed (150, 149, 300, 1, 2) 2.When the mode is set, both the H and X indicators will start to blink. 3.When the H button is pressed, only the H indicat
33、or will blink and aging starts. 4.To end the mode, press the I/1 button or disconnect the power cord from the outlet. During aging, operations will be carried out sequentially in the order of No. 1, No. 2, No. 150, No. 149, and No. 300 slits. The error codes displayed during operations and when erro
34、rs oc- cur are the same as the “AGING MODE” described earlier. DOOR POP UP AGING MODE This mode is used for performing aging of the CD pop up part and door open/close. It is used for checking if operations are performed normally. Method: 1.Turn on the power and press the GROUP FILE , MEGA CTRL and I
35、/1 buttons. Rotate the DISC/CHARACTER knob, select “Door Popup Aging” and press the dial. 2.Aging starts, and door open/close and up/down operations of the pop up part are performed continuously. 3.To end the mode, press the I/1 button. TABLE ROTATION MODE This mode is used for electrical adjustment
36、s. Refer to the sec- tion on Electrical Adjustments. TITLE MEMO SHIFT MODE This mode is used for writing title memo information recorded in this unit in a different unit. Use it for transferring disc memo contents written by the cus- tomer to the new units when replacing the unit, etc. Connection: C
37、ONTROL A1 II connection cord provided Flow of data This unit (Copy source) Another unit (Copy destination) CONTROL A1 II Procedure: 1.Connect two units using the CONTROL A1 II connection cord shown in the figure. 2.With the power on, while pressing the GROUP 7 button and OPEN/CLOSE button of the cop
38、y destination unit, press the +100 button. 3.When the data has been transferred, the fluorescent indicator tube displays “complete” for about 1 second. MODEL NAME DISPLAY Model names can be displayed on the fluorescent indicator tube r r r r 15 ALL LIT MODE This mode is used for lighting the whole f
39、luorescent indicator tubes and LEDs. Procedure: With the power ON, while pressing the GROUP FILE and MEGA CTRL buttons, press the I/1 button. Rotate the DISC/CHARACTER knob, select “All Lit Mode” and press the dial. Both the fluorescent indicator tubes and LEDs will light up com- pletely. To end thi
40、s mode, press the I/1 mode. MECHANISM ADJUSTMENT MODE This mode is used for mechanism adjustments. Refer to the sec- tion on Mechanism Adjustments. SHIPMENT MODE This mode is used for setting the unit to the shipment state. Do not execute it without a proper reason as it erases the memory of the tit
41、le memo recorded by the customer. Procedure: Set the TIMER switch to OFF . Next, with the power ON, while pressing the GROUP FILE button and MEGA CTRL button, press the I/1 button. If the switch state is normal, the model name will be displayed on the fluorescent indicator tube and the unit will set
42、 into the shipment mode. If the various switches are not set to their designated positions, error will be displayed on the fluorescent indicator tube. TITLE MEMO RECORDING CHECK MODE This mode is not required for servicing. Do not execute without a proper reason. If executed, the memory of the title
43、 memo recorded by the cus- tomer will be erased. 16 SECTION 5 TEST MODE ADJ MODE 1.Turn ON the power of the unit, set disc to disc table, and per- form chucking. 2.Remove the power cord from the outlet. 3.To set ADJ mode, connect the TP4 (ADJ) of the MAIN board to ground, and connect the power cord
44、to the outlet. In this mode, table rotation and loading operations are not per- formed because it is taken that the disc has already been chucked. Note: The same operations are also performed in the following when the TP4 (ADJ) is connected to ground after turning on the power. Direct search (moveme
45、nt of sledding motor) is not performed dur- ing accessing Ignored even when GFS becomes L Ignored even when the Q data cannot be read Focus gain does not decrease ADJ Mode Special Functions Table KEY AND DISPLAY CHECK MODE To set this mode, connect the TP5 (AFADJ) on the MAIN board to ground, and co
46、nnect the power cord to the outlet. Note: When this mode is executed, all title memos recorded will be erased. When this button is pressed, “line # No. #” will be displayed. However, these will not be displayed for the following special buttons. However, these will not be displayed for the following
47、 special buttons. x(stop) button: FL segment check (Refer to FL Tube Check Patterns) X(pause) button : FL grid check (Refer to FL Tube Check Patterns) The X LED also lights up simulta- neously. H (play) button : All FL segment and grid will light up. HLED also lights up simultaneously. TIMER switch:
48、 When the switch position isPLAY, the STANDBY LED lights up. It goes OFF when set toOFF. Each time this button is pressed, the value of the “Go+ # keys” increases. Buttons pressed once will not be counted when pressed again. FL Tube Check Patterns Segment check Grid check When the jog dial is rotate
49、d to the right, the GROUP LEDs light up in the order of 1t2.8tHIT LISTtEASY PLAYtARTIST MODEtMEGA CTRLt1. When the jog dial is rotated to the left, the GROUP LEDs light up in the order of 8t7.1tMEGA CTRLtARTIST MODEtEASY PLAYtHIT LISTt8. Abbreviation FL: Fluorescent Indicator Tube Button CONTINUE SHUFFLE PROGRAM GROUP 3 (3) GROUP 8 (8) CHECK Function Servo average display Displays VC, FE, RF, TE and traverse in hexadeci- mal numbers