《Marantz-SR7200-avr-mz02016 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SR7200-avr-mz02016 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、 100 Corporate Drive Mahwah, NJ 07430 Service Bulletin No. : MZ02-016 Date: December 4, 2006 _ Model: SR5200, SR6200, SR7200 Subject: The problem that No sound is out put when AUDIO signal is changed from AC-3 to PCM. Symptom: When the SET is connected to a DVD Player (DV4200, DV6200, VC5200) no sou
2、nd is out put when the AUDIO signal is changed from AC-3 to PCM. Solution: Replace MICRO PROCESSOR (OPT) IC107 on the MAIN CIRCUIT BOARD. Parts: Ref# Description Part Number IC107 CXP7400P100-1 QFP *HU100600R Serial Number Range: The countermeasure applies only to this type of problem. _ CONFIDENTIA
3、LITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MARA
4、NTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility is will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库