《Marantz-SR9600-avr-mz05036 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SR9600-avr-mz05036 电路图 维修手册.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、 100 Corporate Drive Mahwah, NJ 07430 Service Bulletin No. : MZ05-036 Date: January 4, 2007 _ Model: SR9600 Subject: The Backup Transformer Fuse opens. Symptom: This problem (open fuse) can occur when an unsuitable cable (mono plug) is connected to IR-RECEIVER IN Terminal (Stereo mini plug). If the
2、terminal short-circuits from an unsuitable cable, there is a possibility of opening the fuse for the Backup Transformer (TB01) due to over current. Solution: Add a Circuit protector (Polyswitch) and Cut the pattern on the P834 FLD/BACKUP TRANSF PWB. See the attached pictures for details. _ CONFIDENT
3、IALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MA
4、RANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioF
5、ans.CN 收音机爱 好者资料库 _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applic
6、able laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information conta
7、ined in this document. RadioFans.CN 收音机爱 好者资料库 _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected
8、 from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the mi
9、suse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库 _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, conf
10、idential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury
11、or loss resulting from the misuse of the information contained in this document. Parts: Ref# Description Part Number P801 Raychem RXEF005 Polyswitch (50mA) 00MFU05006010 Serial Number Range: This problem applies to the following service code. SR9600 applies to xx00 xxxxxxxxxx. This improvement has done from xx02xxxxxxxxxx and after.