《Marantz-SA8260-sacd-mz02003 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SA8260-sacd-mz02003 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、 100 Corporate Drive Mahwah, NJ 07430 Service Bulletin No. : MZ02-003 Date: December 4, 2006 _ Model: SA8260 Subject: Problems with COPY CONTROL CD playability. Symptom: When a COPY CONTROL CD is played, the sound is interrupted momentarily after about 10 seconds. Solution: Replace the microprocesso
2、r (Q125) on the PV16 SERVO PWB. The version has changed from (V1.26) to (V1.28). Note: Confirm the version number of the microprocessor before replacement. The version number is confirmed from the service mode. 1. To enter service mode - While pressingandbutton and plug in the AC cord. 2. button is
3、pressed twice. 3. Q125, u-COM “Drv Ver XX.XX ” version will be displayed. Parts: Ref# Description Part Number Q125 microprocessor HU01AKY100 Serial Number Range: This improvement has been done in production after the Lot number “MZxxxxxx05xxxx” and later. The Lot number and service modification code
4、 is mentioned the serial number label on the rear panel. (ex.MZxxxxxx05xxxx). _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, co
5、nfidential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility is will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库