1、 100 Corporate Drive Mahwah, NJ 07430 Service Bulletin No. : MZ07-016 Date: February 22, 2007 _ Model: MA-9S2 Subject: Improvement of protective circuit and movement of the level meter. Symptom: 1) To correct a malfunction of the level meter. Issue: The level meter deflects more than the actual volu
2、me and can show over- range. 2) To improve the function of the protective circuit. Issue: If the unit receives repeated short circuits at the speaker connection, the speaker relay will be damaged and the fuse opens. Solution: 1) In addition to the existing 100pF capacitors on the surface of the Powe
3、r Supply PWB (P801), solder one 100pF to each of the C904 and C905 positions on the rear, thereby improving the performance stability. 2) In order to prevent the speaker relay from damage when detecting over current, add the PP01 latch PWB. The latch PWB consists of circuitry that keeps the protecti
4、ve circuit ON after being activated upon detecting over current. The protective circuit stays ON until the power is reactivated. PP01 Latch PWB _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their emplo
5、yees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. N
6、o responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库 To correct the malfunction of the level meter perform the following: 1. Add (solder) 2 100pF caps onto the rear of the POWER SU
7、PPLY PWB (P801) A) As shown above, please solder and bond the capacitors to the board. Capacitor Part No: 00MOF15101540. Part name: APSV 100V J 100pF B) For bonding, please use SONY Chemical SC608LVZ or the equivalent. _ CONFIDENTIALITY NOTICE: The information contained in this document is intended
8、for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination o
9、r copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document. RadioFans.CN 收音机爱 好者资料库 2. Add the PP01 Latch PWB to the MAIN PWB (P601) to
10、prevent the relay from automatically clearing short-circuits. Supplementary PWB: (P101) LATCH PWB ASSY includes the following: Q311: Part No: 00MBA20021210 DTC144EU (Package No: 26) Q312: Part No: 00MBA10014210 DTA144EU (Package No: 16) For bonding, please use SONY Chemical SC608LVZ or the equivalen
11、t. _ CONFIDENTIALITY NOTICE: The information contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and t
12、erms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this do
13、cument. RadioFans.CN 收音机爱 好者资料库 Parts: Ref# Description Part Number NA LATCH PWB ASSY: WIRE(X3)/ CAP.( 100V J 100pF X2) 90M-ZK000690R Serial Number Range: Serial No. A1000634000001 through A1000634000010. A1000634000011 and afterwards: already corrected in production. _ CONFIDENTIALITY NOTICE: The i
14、nformation contained in this document is intended for the exclusive use by MARANTZ Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the MARANTZ Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by MARANTZ for any damage, injury or loss resulting from the misuse of the information contained in this document.