1、Please use this service manual with referring to the user guide ( D.F.U. ) without fail. Service ManualBLU-RAY DISC Player BD7003 /N1B/R1B/S1B TABLE OF CONTENTS SECTION PAGE TECHNICAL SPECIFICATIONS . 1 SERVICE HINTS AND TOOLS . 4 WARNING AND LASER SAFETY INSTRUCTION . 5 LASER BEAM SAFETY PRECAUTION

2、S . 6 IMPORTANT SAFETY PRECAUTIONS . 7 STANDARD NOTES FOR SERVICING. 9 CABINET DISASSEMBLY INSTRUCTIONS . 13 HOW TO INITIALIZE THE BLU-RAY DISC PLAYER . 16 TRAY LOCK MODE . 17 SERVICE MODE . 18 FIRMWARE RENEWAL MODE . 20 TROUBLESHOOTING . 22 WIRING DIAGRAM . 28 BLOCK DIAGRAMS . 29 LEAD IDENTIFICATIO

3、NS . 35 WAVEFORMS . 36 SCHEMATIC DIAGRAMS AND TEST POINTS . 37 PARTS LOCATION . 81 EXPLODED VIEWS . 91 PARTS LIST . 93 BD7003 Part no. 90M12DW855020 First Issue 2008.11 MZ BD7003 MARANTZ DESIGN AND SERVICE Using superior design and selected high grade components, MARANTZ company has created the ulti

4、mate in stereo sound. Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered ei

5、ther by mail or by Fax. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is

6、 required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void. NOTE ON SAFETY : Symbol Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol . Any other component

7、substitution (other than original type), may increase risk of fire or electrical shock hazard. SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins ( with unit NOT connected

8、 to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer. In case of d

9、ifficulties, do not hesitate to contact the Technical Department at above mentioned address. 080702MZ USA MARANTZ AMERICA, INC 100 CORPORATE DRIVE MAHWAH, NEW JERSEY 07430 USA EUROPE / TRADING D 5,956,674; 5,974,380; 5,978,762; 6,487,535 5,956,674; 5,974,380; 5,978,762; 6,487,535 5,956,674; 5,974,38

10、0; 5,978,762; 6,487,535 5,956,674; 5,974,380; 5,978,762; 6,487,535 5,956,674; 5,974,380; 5,978,762; 6,487,535 when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6) 4.Release the flat pack-IC from the C

11、BA using tweezers. (Fig. S-1-6) CAUTION: 1.The Flat Pack-IC shape may differ by models. Use an appropriate hot-air flat pack-IC desoldering machine, whose shape matches that of the Flat Pack-IC. 2.Do not supply hot air to the chip parts around the flat pack-IC for over 6 seconds because damage to th

12、e chip parts may occur. Put masking tape around the flat pack-IC to protect other parts from damage. (Fig. S-1-2) Top View OutIn Bottom View Input 5 10 Pin 1 Pin 1 FFC Cable Connector CBA * Be careful to avoid a short circuit. Fig. S-1-1 STANDARD NOTES FOR SERVICING 10 1-4-2DVDP_SN 3.The flat pack-I

13、C on the CBA is affixed with glue, so be careful not to break or damage the foil of each pin or the solder lands under the IC when removing it. With Soldering Iron: 1.Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder flux which is applied to all pins o

14、f the flat pack-IC, you can remove it easily. (Fig. S-1-3) 2.Lift each lead of the flat pack-IC upward one by one, using a sharp pin or wire to which solder will not adhere (iron wire). When heating the pins, use a fine tip soldering iron or a hot air desoldering machine. (Fig. S-1-4) 3.Bottom of th

15、e flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6) 4.Release the flat pack-IC from the CBA using tweezers. (Fig. S-1-6) Hot-air Flat Pack-IC Desoldering

16、 Machine CBA Flat Pack-IC Tweezers Masking Tape Fig. S-1-2 Flat Pack-IC Desoldering Braid Soldering Iron Fig. S-1-3 Fine Tip Soldering Iron Sharp Pin Fig. S-1-4 11 1-4-3DVDP_SN With Iron Wire: 1.Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder flux wh

17、ich is applied to all pins of the flat pack-IC, you can remove it easily. (Fig. S-1-3) 2.Affix the wire to a workbench or solid mounting point, as shown in Fig. S-1-5. 3.While heating the pins using a fine tip soldering iron or hot air blower, pull up the wire as the solder melts so as to lift the I

18、C leads from the CBA contact pads as shown in Fig. S-1-5. 4.Bottom of the flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6) 5.Release the flat pack-IC fr

19、om the CBA using tweezers. (Fig. S-1-6) Note: When using a soldering iron, care must be taken to ensure that the flat pack-IC is not being held by glue. When the flat pack-IC is removed from the CBA, handle it gently because it may be damaged if force is applied. 2. Installation 1.Using desoldering

20、braid, remove the solder from the foil of each pin of the flat pack-IC on the CBA so you can install a replacement flat pack-IC more easily. 2.The “” mark on the flat pack-IC indicates pin 1. (See Fig. S-1-7.) Be sure this mark matches the 1 on the PCB when positioning for installation. Then presold

21、er the four corners of the flat pack-IC. (See Fig. S-1-8.) 3.Solder all pins of the flat pack-IC. Be sure that none of the pins have solder bridges. To Solid Mounting Point Soldering Iron Iron Wire or Hot Air Blower Fig. S-1-5 Fine Tip Soldering Iron CBA Flat Pack-IC Tweezers Fig. S-1-6 Example : Pi

22、n 1 of the Flat Pack-IC is indicated by a mark. Fig. S-1-7 Presolder CBA Flat Pack-IC Fig. S-1-8 12 1-4-4DVDP_SN Instructions for Handling Semi- conductors Electrostatic breakdown of the semi-conductors may occur due to a potential difference caused by electrostatic charge during unpacking or repair

23、 work. 1. Ground for Human Body Be sure to wear a grounding band (1 M) that is properly grounded to remove any static electricity that may be charged on the body. 2. Ground for Workbench Be sure to place a conductive sheet or copper plate with proper grounding (1 M) on the workbench or other surface

24、, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing. CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA 13 1-5-1E5J70DC CABINET DI

25、SASSEMBLY INSTRUCTIONS 1. Disassembly Flowchart This flowchart indicates the disassembly steps to gain access to item(s) to be serviced. When reassembling, follow the steps in reverse order. Bend, route, and dress the cables as they were originally. 2. Disassembly Method Note: (1) Identification (lo

26、cation) No. of parts in the figures (2) Name of the part (3) Figure Number for reference (4) Identification of parts to be removed, unhooked, unlocked, released, unplugged, unclamped, or desoldered. P = Spring, L = Locking Tab, S = Screw, CN = Connector * = Unhook, Unlock, Release, Unplug, or Desold

27、er e.g. 2(S-2) = two Screws (S-2), 2(L-2) = two Locking Tabs (L-2) (5) Refer to “Reference Notes.” About tightening screws When tightening screws, tighten them with the following torque. Reference Notes 1.CAUTION 1: Locking Tabs (L-1) ,(L-2) and (L-3) are fragile. Be careful not to break them. 2.The

28、 FE Main CBA 2-5-8-0-CLEAR Release from Service Mode Press the POWER OFF button to turn off power. Screen saver/Auto Power Off in Service Mode These functions are not performed in Service Mode. After entering, Fig. k appears on the screen and Fig. l appears on the VFD. Available button in service mo

29、de Note:Press the number key to select items. Or, press the cursor button (up/down) to select items and press ENTER button. Buttoncondition ENTEREnter the next level POWERTurn the power off (when the service mode is completed) 18Enter the selected item (next level) OTHERNot available INDICATIONDESCR

30、IPTIONREMARK Model NameModel NameE5J*D, etc. RegionBD region - DVD regionA-1, etc. Release Ver.Release versionD.jpp, etc. 1-7-4E5J70FW Entering Service Mode In power on condition, no discs and tray close, it will be entered into service mode by the following operation using the remote controller. Ho

31、wever, it will not be entered when Media Select Item is SD Memory. Service Mode by using remote controller Press the following buttons on the remote controller in power on condition, no discs and tray close; 2-5-8-0-CLEAR Release from Service Mode Press the POWER OFF button to turn off power. Screen

32、 saver/Auto Power Off in Service Mode These functions are not performed in Service Mode. After entering, Fig. k appears on the screen and Fig. l appears on the VFD. Available button in service mode Note:Press the number key to select items. Or, press the cursor button (up/down) to select items and p

33、ress ENTER button. Buttoncondition ENTEREnter the next level POWERTurn the power off (when the service mode is completed) 18Enter the selected item (next level) OTHERNot available INDICATIONDESCRIPTIONREMARK Model NameModel NameE5J*D, etc. RegionBD region - DVD regionA-1, etc. Release Ver.Release ve

34、rsionD.jpp, etc. Service Mode 1. Mecha Test 2. VFD/LED Test 3: Error Rate 4: LD Test 5: RS-232C 6: Channel Test 7: SD Card Test 8: Default Setting Model Name: :E5J*D Region :A-1 Release Ver. :*.* ADSP1/2 Ver. :*/* PLD Ver. :* FPGA Ver. :* I/P Scaler Ver.:* Fig. k Service Mode (Main menu) * Firmware

35、Version differs depending on the models, and this indication is one example. SERVICE MODE Button Condition ENTER Enter the next level POWER Turn the power off (when the service mode is completed) 18 Enter the selected item (next level) OTHER Not available Indication Description Remark Model Name Mod

36、el Name E5J*D, etc. Region BD region - DVD region A-1, etc. Release Ver. Release version D.jpp, etc. 19 Available test in service mode 1st level 2nd level 3rd level Description 1 Mecha test 1 Tray Aging Aging of tray open/close 2 TOC Read TOC reading 3 Heat Run Tray close - TT1 playback - TT10 playb

37、ack - Tray open - Tray close 2 VFD/LED Test 1 All On Turning on all VFD 2 All Off Turning off all VFD 3 Error Rate Displaying Error rate, Jitter during playback 4 LD Test 1 LD Power 1 Off Turning off LD 2 BD Turning on BD LD 3 DVD Turning on DVD LD 4 CD Turning on CD LD 2 Operating Time Displaying L

38、D Operation Time (with clear function) 5 Channel Test 1 TEST TONE 1 Center/ Subwoofer/ Front LR 2 Surround LR/ Surround Back LR 2 Front Lch 3 Center 4 Front Rch 5 Surround Rch 6 Surround Back Rch 7 Surround Back Lch 8 Surround Lch 9 Sub woofer 6 RS-232C 1 Parity Setting 1 Even Setting even parity 2

39、Non Setting non parity 2 Version Up Mode Realta Version up with connecting RS-232C 7 SD Card Test 8 Default Setting Default setting Note : If some test are performed continuously, any error will occur. 20 1-7-1E5J70FW FIRMWARE RENEWAL MODE 1.Turn the power on and remove the disc on the tray. 2.To pu

40、t the BD player into version up mode, press 9, 8, 7, 6, and POP UP MENU/MENU buttons on the remote control unit in that order. The tray will open automatically. Fig. a appears on the screen and Fig. b appears on the VFD. The BD player can also enter the version up mode with the tray open. In this ca

41、se, Fig. a will be shown on the screen while the tray is open. 3.Load the disc for version up. 4.The BD player enters the F/W version up mode automatically. Fig. c appears on the screen and Fig. d appears on the VFD. If you enter the F/W for different models, “Disc Error” will appear on the screen,

42、then the tray will open automatically. The appearance shown in (*1) of Fig. c is described as follows: 5.After programming is finished, the checksum on the VFD (Fig. f). At this time, no button is available. 6.Unplug the AC cord from the AC outlet. Then plug it again. 7.Turn the power on. 8.Press 1,

43、 2, 3, 4, and DISPLAY buttons on the remote control unit in that order. Fig. g appears on the screen. F/W VERSION UP MODEModel No. * Ver. *.* Please insert a Disc for F/W Version Up * differs depending on the models. Fig. a Version Up Mode Screen Fig. b VFD in Version Up Mode 1. ALL Now Loading. Ver. : *.* *B*.bin (*1) F/W VERSION UP MODEModel No : * Ver. : *.* ADSP 1/2 Ver. : *