1、START:|g1cz3Z09ximWbk6cjE4rRA=|mg9g+GZSrubJjFbzRGSxCVc7rGTC/B0gkPTJx5lic8=|PLXqzLbC2dLvdexZ9XDk1w=|:END Integrated Amplifier PM8005 /N1B/N1SG U1B/K1B PM8005 S1165V06DM/DG1512 Copyright 2015 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. V

2、er. 6 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifications and design are subject to change without notice. Please refer to the

3、 MODIFICATION NOTICE. Service Manual RadioFans.CN 收音机爱 好者资料库 ABOUT THIS MANUAL .3 What you can do with this manual .3 Using Adobe Reader (Windows version) .4 SAFETY PRECAUTIONS .6 NOTE FOR SCHEMATIC DIAGRAM .7 NOTE FOR PARTS LIST .7 TECHNICAL SPECIFICATIONS .9 DIMENSION .9 DISASSEMBLY .10 1. FRONT P

4、ANEL ASSY .11 2. HEAT SINK ASSY .12 3. PHONO AMP PCB .13 4. STANDBY PCB .13 5. REAR PANEL ASSY .14 6. MAIN PCB .14 SPECIAL MODE .15 1. SERVICE MODE .15 2. PROTECTION MODE .16 Procedure after Replacing the MicroPROCESSOR, etc.18 ADJUSTMENT .19 TROUBLE SHOOTING .21 1. The power can not be turned on. (

5、STANDBY LED does not light (STANDBY MODE) .21 2. The power can not be turned on. (STANDBY LED lights flash) .21 3. STANDBY LED FLASHES WHILE USING UNIT .22 4. The power turned on, but a sound does not output normally. .22 LEVEL DIAGRAM .23 BLOCK DIAGRAM .23 POWER DIAGRAM .23 WIRING DIAGRAM .24 PRINT

6、ED Circuit BOARDS .25 SCHEMATIC DIAGRAMS (1/6 ) .29 MAIN .29 MAIN / POWER STAGE 1/2 .30 MAIN / POWER STAGE 2/2 .31 U-COM / SELECTOR .32 POWER AMP / SPK TERMINAL / TONE .33 HEADPHONE / POWER SW / STANDBY .34 PHONO AMP / SPK TERMINAL / VOLUMERECT .35 EXPLODED VIEW .36 PACKING VIEW .37 SEMICONDUCTORS .

7、38 1. ICs .38 2 CONTENTS RadioFans.CN 收音机爱 好者资料库 Jump to the target of a schematic diagram connector Click the Ref. No. of the target connector in the red box around a schematic diagram connector. The screen jumps to the target connector. Pagemagnificationstaysthesameasbeforethe jump. ABOUT THIS MAN

8、UAL Read the following information before using the service manual. What you can do with this manual Search for a Ref. No. (phrase) (Ctrl+Shift+F) You can use the search function in Acrobat Reader to search for a Ref. No. in schematic diagrams, printed wiring circuit diagrams, block diagrams, and pa

9、rts lists. 1.Press Ctrl+Shift+Fonthekeyboard. The Search window appears. 2.EntertheRef.No.youwanttosearchforinthe Search window, and then click the Search button. A list of search results appears. 3.Click an item on the list. The screen jumps to the page for that item, and the searchphraseisdisplaye

10、d. Ctrl Shift F 3 RadioFans.CN 收音机爱 好者资料库 Using Adobe Reader (Windows version) Properties Click this button and check that the printer is set to a suitable paper size. Page to print Select the following checkbox. More Options : Current View Page Sizing & Handling Select the following checkbox. Size

11、/ Size Options : Fit Add notes to this data (Sign) TheSignfunctionletsyouaddnotestothedatain this manual. Savethefileonceyouhavefinishedaddingnotes. Example using Adobe Reader X On the View menu, click Sign. The Sign pane appears. Example using Adobe Reader 9 On the Document menu, click Sign. Magnif

12、y schematic / printed circuit board diagrams - 1 (Ctrl+Space, mouse operation) Press Ctrl+Spaceonthekeyboardanddragthe mousetoselecttheareayouwanttoview. Theselectedareaismagnified. Whenyouwanttomovetheareashown,hold down Space and drag the mouse. Whenyouwanttoshowafullpageview,press Ctrl+0onthekeyb

13、oard. CtrlSpace 0 Print a magnified part of the manual ThePropertiesdialogboxandfunctionswillvarydependingonyourprinter. 1. Dragthemousetomagnifythepartyouwanttoprint. 2. On the File menu, click Print. 3. ConfigurethefollowingsettingsinthePrintdialogbox. 4. Click the Print button to start printing.

14、4 Magnify schematic / printed circuit board diagrams - 2 (Pan & Zoom function) ThePan&Zoomfunctionletsyouseewhichpartof amagnifieddiagramisbeingshowninaseparate window. Example using Adobe Reader X On the View menu, point to Zoom, and then click Pan & Zoom. The Pan & Zoom window appears on the scree

15、n. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Pan & Zoom Window. Magnify schematic / printed circuit board diagrams - 3 (Loupe Tool function) TheLoupeToolfunctionletsyoumagnifyaspecific part of a diagram in a separate window. Example using Adobe Reader X O

16、n the View menu, point to Zoom, and then click Loupe Tool. The Loupe Tool window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Loupe Tool Window. 5 SAFETY PRECAUTIONS The following items should be checked for continued protection of the

17、 customer and the service technician. leakage current check Beforereturningthesettothecustomer,besuretocarryouteither(1)aleakagecurrentcheckor(2)alinetochassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less t

18、han 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on,offandstandbymode),ifapplicable. CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the c

19、autions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock! (1) AnACvoltageisimpressedonthisset,soifyou touch

20、internal metal parts when the set is energized, youmaygetanelectricshock.Avoidgettingan electricshock,byusinganisolatingtransformer and wearing gloves when servicing while the set is energized,orbyunpluggingthepowercordwhen replacing parts, for example. (2) Therearehighvoltagepartsinside.Handlewith

21、extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufacturedfromsheetmetal,theremaybeburrson theedgesofparts.Theburrscouldcauseinjuryiffingers are moved across them in some rare cases. Wear gloves toprotectyourhands. Use

22、only designated parts! Thesetspartshavespecificsafetyproperties(fire resistance,voltageresistance,etc.).Besuretouseparts which have the same properties for replacement. The burrs have the same properties. In particular, for the importantsafetypartsthatareindicatedbythez mark on schematic diagrams an

23、d parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed! Forsafetyseasons,somepartsusetapes,tubesorother insulatingmaterials,andsomepartsaremountedaway from the surface of printed circuit boards. Care is also takenwiththepositio

24、nsofthewiresbyarrangingthem andusingclampstokeepthemawayfromheatingand highvoltageparts,sobesuretoseteverythingbackas itwasoriginallyplaced. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positio

25、ns, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safetyisensured. (Insulationcheckprocedure) Unplug the power cord from the power outlet, disconnect the

26、 antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistancevaluebetweentheinplugandtheexternally exposedmetalparts(antennaterminal,headphones terminal,inputterminal,etc.)is1Morgreater.Ifitis less, the set must be inspected and repaired. Ma

27、nyoftheelectricandthestructuralpartsusedinthe sethavespecialsafetyproperties.Inmostcasesthese propertiesaredifficulttodistinguishbysight,andtheuse ofreplacementpartswithhigherratings(ratedpower andwithstandvoltage)doesnotnecessarilyguarantee thatsafetyperformancewillbepreserved.Partswith safetyprope

28、rtiesareindicatedasshownbelowonthe wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1)Schematicdiagrams .Indicatedbythez mark. (2)Partslists .Indicatedbythez mark. The use of parts other than the designated part

29、s could cause electric shocks,firesorotherdangerous situations. CAUTION Concerning important safety parts 6 NOTE FOR SCHEMATIC DIAGRAM WARNING: Partsindicatedbythezmarkhavecriticalcharacteristics.UseONLYreplacementpartsrecommendedbythemanufacturer. CAUTION: Beforereturningthesettothecustomer,besuret

30、ocarryouteither(1)aleakagecurrentcheckor(2)alinetochassisresistancecheck. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DONOTreturnthesettothecustomerunlesstheproblemisidentified

31、andremedied. NOTICE: ALLRESISTANCEVALUESINOHM.k=1,000OHM/M=1,000,000OHM ALLCAPACITANCEVALUESAREEXPRESSEDINMICROFARAD,UNLESSOTHERWISEINDICATED.PINDICATESMICRO-MICRO FARAD.EACHVOLTAGEANDCURRENTAREMEASUREDATNOSIGNALINPUTCONDITION.CIRCUITANDPARTSARESUBJECT TOCHANGEWITHOUTPRIORNOTICE. NOTE FOR PARTS LIST

32、 1.Partsindicatedbynsp on this table cannot be supplied. 2.Whenorderingapart,makeacleardistinctionbetween1andI(i)toavoidmis-supplying. 3.Apartorderedwithoutspecifyingitspartnumbercannotbesupplied. 4.Partindicatedby mark is not illustrated in the exploded view. WARNING:Partsindicatedbythezmarkhavecri

33、ticalcharacteristics.UseONLYreplacementpartsrecommendedbythemanufacturer. INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT Electrostaticbreakdownofthesemi-conductorsoropticalpickupmayoccurduetoapotentialdifferencecausedby electrostatic charge during unpacking or repair work. 1. GroundforHu

34、manBody Besuretowearagroundingband(1M)thatisproperlygroundedtoremoveanystaticelectricitythatmaybe chargedonthebody. 2. GroundforWorkbench Besuretoplaceaconductivesheetorcopperplatewithpropergrounding(1M)ontheworkbenchorothersurface, wherethesemi-conductorsaretobeplaced.Becausethestaticelectricitycha

35、rgeonclothingwillnotescapethrough thebodygroundingband,becarefultoavoidcontactingsemi-conductorswithyourclothing CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA 7 Personal notes: 8 RMS Power output (for U / N / F model) (20 Hz 20 kHz simultaneous drive of both channels) : 70 W x 2 (8 /

36、ohms load) 100 W x 2 (4 /ohms load) RMS Power output (for K model) (20 Hz 20 kHz simultaneous drive of both channels) : 65 W x 2 (8 /ohms load) 95 W x 2 (4 /ohms load) Total harmonic distortion (20 Hz 20 kHz simultaneous drive of both channels, 8 /ohms load) : 0.02 % Output band width (8 /ohms load,

37、 0.06 %) : 5 Hz 60 kHz Frequency response (CD, 1 W, 8 /ohms load) : 5 Hz 100 kHz 3 dB Dumping factor (8 /ohms load, 40 Hz 20 kHz) : 100 Input sensitivity/Input impedance PHONO (MM) : 2 mV / 47 k/kohms CD, TUNER, NETWORK, AUX, RECORDER : 200 mV / 20 k/kohms POWER AMP DIRECT IN : 1.6 V / 15 k/kohms Ou

38、tput voltage/Output impedance PRE OUT : 1.6 V / 600 /ohms Maximum allowable PHONO input level (1 kHz) MM : 100 mV RIAA deviation (20 Hz 20 kHz) : 0.5 dB S/N (IHF-A, 8 /ohms load) PHONO (MM) : 87 dB (5 mV input, 1 W output) CD, TUNER, NETWORK, AUX, RECORDER : 106 dB (2 V input, Rated output POWER AMP

39、 DIRECT IN : 125 dB (Rated output) Tone control Bass (50 Hz) : 10 dB Mid (900 Hz) : 6 dB Treble (15 kHz) : 10 dB Power requirement (for U model) : AC 120 V, 60 Hz Power requirement (for N model) : AC 230 V, 50/60 Hz Power requirement (for K model) : AC 220 V, 50 Hz Power requirement (for F model) :

40、AC 100 V, 50/60 Hz Power consumption (EN60065 / UL60065) : 220 W Power consumption in standby mode : 0.2 W Unit : in. (mm) Weight : 12.0 kg 329 379 2255945 17111 128 440 340 56 5050 1733 TECHNICAL SPECIFICATIONS DIMENSION 9 FRONT PANEL ASSY See DISASSEMBLY 1. FRONT PANEL ASSY and EXPLODED VIEW u-COM

41、 PCB (110151-1) (Ref. No. of EXPLODED VIEW : P4) STANDBY LED PCB (110151-2) (Ref. No. of EXPLODED VIEW : P5) INPUT SEL PCB (110151-3) (Ref. No. of EXPLODED VIEW : P6) TONE PCB (110151-4) (Ref. No. of EXPLODED VIEW : P7) HEADPHONE PCB (110151-5) (Ref. No. of EXPLODED VIEW : P8) POWER SW PCB (110151-7

42、) (Ref. No. of EXPLODED VIEW : P10) VOLUME PCB (110152-3) (Ref. No. of EXPLODED VIEW : P14) REAR PANEL ASSY See DISASSEMBLY 5. REAR PANEL ASSY and EXPLODED VIEW SPK TERMINAL PCB (110152-2) (Ref. No. of EXPLODED VIEW : P13) MAIN PCB See DISASSEMBLY 6. MAIN PCB and EXPLODED VIEW MAIN PCB (110150-1) (Ref. No. of EXPLODED VIEW : P1) PHONO AMP PCB See DISASSEMB