1、R PD4293DPD4293D Plasma Monitor Service Manual PD4293D /U1M PD4293D 07AW855010 AVD First Issue:2002.01 Please use this service manual with referring to the user guide (D.F.U) without fail. Printed in Japan REMARK : The PD4293D is a same product as the PX-42VM3G except the brand indications and acces

2、sories. Please refer to the PX-42VM3G service manual (PART No. 009A) except following parts. POS. NO. VERS.PART NO.DESCRIPTION PK24ZK334W0020RC4293DPD (03S120091) PK2807AW851210USER GUIDE for PD4293D (07S900025) M3007AW248500FRONT PANEL ASSY (029DS0281) Following spare parts are different from PX-42

3、VM3G ones. (refer page 8-1 ) INPUT SELECTVOLUME POWER/STANDBY Printed on 100% Recycled Paper RadioFans.CN 收音机爱 好者资料库 MARANTZ DESIGN AND SERVICE Using superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound. Only original MARANTZ parts can insure t

4、hat your MARANTZ product will continue to perform to the specifi cations for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part numbe

5、r has to be specifi ed. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form o

6、r Fax. must be signed, otherwise such part order will be considered as null and void. SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins ( with unit NOT connected to AC ma

7、ins and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verifi ed before it is return to the user/customer. Ref. UL Standard No.

8、 1492. In case of diffi culties, do not hesitate to contact the Technical Department at above mentioned address. 020110MIT SUPERSCOPE TECHNOLOGIES, INC. USA MARANTZ AMERICA, INC 1100 MAPLEWOOD DRIVE ITASCA, IL. 60143 USA PHONE : 630 - 741 - 0300 FAX : 630 - 741 - 0301 BRAZIL PHILIPS DA AMAZONIA IND.

9、 ELET. ITDA CENTRO DE INFORMACOES AO CEP 04698-970 SAO PAULO, SP, BRAZIL PHONE : 0800 - 123123 (Discagem Direta Gratuita) FAX : +55 11 534. 8988 JAPANTechnical MARANTZ JAPAN, INC. 35- 1, 7- CHOME, SAGAMIONO SAGAMIHARA - SHI, KANAGAWA JAPAN 228-8505 PHONE : +81 42 748 1013 FAX : +81 42 741 9190 EUROP

10、E / TRADING MARANTZ EUROPE B.V. P. O. BOX 8744, BUILDING SILVERPOINT BEEMDSTRAAT 11, 5653 MA EINDHOVEN THE NETHERLANDS PHONE : +31 - 40 - 2507844 FAX : +31 - 40 - 2507860 TECHNICAL AUDIO GROUP PTY, LTD 558 DARLING STREET, BALMAIN, NSW 2041, AUSTRALIA PHONE : 61 - 2 - 9810 - 5300 FAX : 61 - 2 - 9810

11、- 5355 CANADA LENBROOK INDUSTRIES LIMITED 633 GRANITE COURT, PICKERING, ONTARIO L1W 3K1 CANADA PHONE : 905 - 831 - 6333 FAX : 905 - 831 - 6936 AUSTRALIA QualiFi Pty Ltd, 24 LIONEL ROAD, MT. WAVERLEY VIC 3149 AUSTRALIA PHONE : +61 - (0)3 - 9543 - 1522 FAX : +61 - (0)3 - 9543 - 3677 NEW ZEALAND WILDAS

12、H AUDIO SYSTEMS NZ 14 MALVERN ROAD MT ALBERT AUCKLAND NEW ZEALAND PHONE : +64 - 9 - 8451958 FAX : +64 - 9 - 8463554 THAILAND MRZ STANDARD CO., LTD 746 - 754 MAHACHAI ROAD., WANGBURAPAPIROM, PHRANAKORN, BANGKOK, 10200 THAILAND PHONE : +66 - 2 - 222 9181 FAX : +66 - 2 - 224 6795 TAIWAN PAI- YUING CO.,

13、 LTD. 6 TH FL NO, 148 SUNG KIANG ROAD, TAIPEI, 10429, TAIWAN R.O.C. PHONE : +886 - 2 - 25221304 FAX : +886 - 2 - 25630415 MALAYSIA WO KEE HONG ELECTRONICS SDN. BHD. SUITE 8.1, LEVEL 8, MENARA GENESIS, NO. 33, JALAN SULTAN ISMAIL, 50250 KUALA LUMPUR, MALAYSIA PHONE : +60 3 - 2457677 FAX : +60 3 - 245

14、8180 AMERICAS MARANTZ PROFESSIONAL PRODUCTS 2640 WHITE OAK CIRCLE, SUITE A AURORA, ILLINOIS 60504 USA PHONE : 630 - 820 - 4800 FAX : 630 - 820 - 8103 AUSTRALIA KOREA MK ENTERPRISES LTD. ROOM 604/605, ELECTRO-OFFICETEL, 16-58, 3GA, HANGANG-RO, YONGSAN-KU, SEOUL KOREA PHONE : +822 - 3232 - 155 FAX : +

15、822 - 3232 - 154 SINGAPORE WO KEE HONG DISTRIBUTION PTE LTD 130 JOO SENG ROAD #03-02 OLIVINE BUILDING SINGAPORE 368357 PHONE : +65 858 5535 / +65 381 8621 FAX : +65 858 6078 RadioFans.CN 收音机爱 好者资料库 MODEL PX-42VM3A PX-42VM3G No. 009A PlasmaSync Multimedia Monitor SERVICE MANUAL SAFETY CAUTION: Before

16、 servicing this chassis, it is important that the service technician read and follow the “Safety Precautions” and “Product Safety Notice” in this Service Manual. WARNING: SHOCK HAZARD - Use an isolation transformer when servicing. Better Service Better Reputation Better Profit RadioFans.CN 收音机爱 好者资料

17、库 CONTENTS SAFETY PRECAUTIONS . 2-1 USERS MANUAL . 3-1 TROUBLESHOOTING . 4-1 METHOD OF ADJUSTMENTS . 5-1 METHOD OF DISASSEMBLY . 6-1 PACKAGING. 7-1 PART LIST . 8-1 CONNECTION DIAGRAMS. 9-1 BLOCK DIAGRAM . 10-1 1-1 SAFETY PRECAUTIONS 2-1 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION:TO REDUCE TH

18、E RISK OF ELECTRIC SHOCK, DO NOT OPEN REAR COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol warns the user that unin- sulated voltage within the unit may have sufficient magnitude to cause electric shock. Therefore, it is dangerous to make any kind

19、 of contact with any part inside of this unit. This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included. Therefore, it should be read carefully in order to avoid any problems. ATTENTION RISQUE DELECTROCUTION NE PAS OUVRIR ATTENTION

20、:POUR EVITER LES RISQUES D ELECTROCUTION, NE PAS ENLEVER LE CONVERCLE ARRRE. AUCUN DES ELEMENTS INTERNES NE DOIT ETRE REPARE PAR LUTILISATEUR. NE CONFIER L ENTRETIEN QUA UN PERSONNEL QUALIFIE. Lclair flch dans un triangle quilatral est destin avertir lutilisateur de la prsence, dans lappareil, dune

21、zone non-isole soumise une haute tension dont lintensit est suffi- sante pour constituer un risque dlectro- cution. Le point dexclamation dans un triangle qui- latral est destin attirer l attention de luti- lisateur sur la prsence dinformations de founctionnement et dentretien importantes dans la br

22、ochure accompagnant lappareil. WARNING HEATSINK MAY BE ENERGIZED. TEST BEFORE TOUCHING. 1. Before returning an instrument to the customer, al- ways make a safety check of the entire instrument, in- cluding, but not limited to, the following items. a. Be sure that no built-in protective devices are d

23、efective and/or have been defeated during servicing. (1) Protective shields are provided on this chassis to protect both the technician and the customer. Correctly replace all missing pro- tective shields, including any removed for serv- icing convenience. (2) When reinstalling the chassis and/or ot

24、her assembly in the cabinet, be sure to put back in place all protective devices, including,but not limited to, nonmetallic control knobs,insulating fishpapers,adjustment and compartment covers/shields, and isolation re- sistor/capacitor networks. Do not operate this instrument or permit it to be op

25、erated with- out all protective devices correctly installed and functioning. b. Be sure that there are no cabinet openings through which an adult or child might be able to insert their fingers and contact a hazardous volt- age. Such opening include,but are not limited to, (1) spacing between the pic

26、ture tube and the cabinet mask, (2) excessively wide cabinet ven- tilation slots, and (3) an improperly fitted and/or incorrectly secured cabinet back cover. c. Leakage Current Hot Check With the instru- ment completely reassembled,plug the AC line cord directly into a 240V AC outlet. (Do not use an

27、 isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standards In- stitutes (ANSI) C101.1 Leakage Current for Ap- pliances and Underwriters Laboratories(UL) 1950. With the instrument AC switch first in the ON position and th

28、en in the OFF position, mea- sure from a known earth ground (metal waterpipe, conduit,etc.) to all exposed metal parts of the instrument(antennas, handle bracket, metal cabinet, screwheads, metallic overlays, control shafts,etc.), especially any ex- posed metal parts that offer an electrical return

29、path to the chassis. Any current measured must not exceed 3.5 milliamp. Reverse the instru- ment power cord plug in the outlet and repeat test.ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE INSTRUMENT TO THE CUST

30、OMER. AC Leakage Test 2. Read and comply with all caution and safety-related notes on or inside the Monitor cabinet, on the Pro- jection Monitor chassis, or on the picture tube. 3. Design Alteration Warning Do not alter or add to the mechanical or electrical design of this unit. Design alterations a

31、nd additions, including, but not limited to, circuit modifications and the addition of the items such as auxiliary audio and/or video out- put connections might alter the safety characteris- tics of this Monitor and create a hazard to the user. Any design alterations or additions will void the manuf

32、acturers warranty and will make you,the servicer,responsible for personal injury or property damage resulting therefrom. 4. Hot Chassis Warning a. Some MultiSync Monitor chassis are electrically connected directly to one conductor of the AC power cord and may be safely serviced without an isolation

33、transformer only if the AC power plug is inserted so that the chassis is connected to the ground side of the AC power source. To confirm that the AC power plug is in- serted correctly, with an AC voltmeter measure be- tween the chassis and a known earth ground. If a voltage reading in excess of 1.0V

34、 is obtained, re- move and reinsert the AC power plug in the oppo- site polarity and again measure the voltage poten- tial between the chassis and a known earth ground. b. Some Plasma chassis normally have 85V AC (RMS), between chassis and earth ground regard- less of the AC plug polarity. These cha

35、ssis can be safely serviced only with an isolation transformer inserted in the power line between the receiver and the AC power source, for both personnel and test equipment protection. c. Some Plasma chassis have a secondary ground systems in addition to the main chassis ground. This secondary grou

36、nd sys- tem is not isolated from the AC power line. The two ground system are electrically separated by insulat- ing material that must not be defeated or altered. (READING SHOULD NOT BE ABOVE 3.5 mA) LEAKAGE CURRENT TESTER + EARTH GROUND TEST ALL EXPOSED METAL SURFACES 3-WIRE CORD ALSO TEST WITH PL

37、UG REVERSED (USING AC ADAPTER PLUG AS REQUIRED) DEVICE UNDER TEST 2-2 SAFETY PRECAUTIONS 5. Observe original lead dress. Take extra care to assure correct lead dress in the following areas: a. near sharp edges, b. near thermally hot parts be sure that leads and components do not touch thermally hot

38、parts, c. the AC supply, d. high volt- age, and e. antenna wiring. Always inspect in all areas for pinched, out-of-place, or frayed wiring. Do not change spacing between components, and be- tween components and the printed-circuit board. Check AC power cord for damage. 6. Components,parts, and/or wi

39、ring that appear to have overheated or are otherwise damaged should be replaced with components, parts, or wiring that meet original specifications. Additionally,determine the cause of overheating and/or damage and, if necessary, take corrective action to remove any potential safety hazard. 7. PRODU

40、CT SAFETY NOTICE Many MultiSync Monitor electrical and mechanical parts have spe- cial safety-related characteristics some of which are often not evident from visual inspection, nor can the protection they give necessarily be ob- tained by replacing them with components rated for higher voltage, wat

41、tage, etc. Parts that have special safety characteristics are identified in this service data by shading with a mark on schemat- ics and by shading or a mark in the parts list. Use of a substitute replacement part that does not have the same safety characteristics as the recom- mended replacement pa

42、rt in this service data parts list might create shock, fire, and/or other hazards. SAFETY PRECAUTIONS 2-3 1. Avant de remettre un appareil un client, faire toujours dabord un examen de scurit de lappareil en entier comprenant, mais ne sy limitant pas les points cits ci-dessous: a. Vrifier qu aucun d

43、es dispositifs de protection ne soit dfectueux ou n ait t endommag pendant les travaux. (1) Les volets protecteurs sur ce chssis ont t monts pour protger aussi bien le technicien que le client. Remplacer correctement tous les volets protecteurs manquants, aussi bien que ceux qui ont pu tre enlevs po

44、ur la commodit des travaux. (2) Quand vous remettez le chssis ou dautres assemblages ensemble dans le coffret, vrifier qu ont t remis leur place tous les dispositifs de protection, comprenant mais ne s y limitant point, les boutons de contrle non-mtalliques, les feuilles disolation, les couverture/v

45、olets de lajustement et du compartiment, et lisolation des rseaux rsistance/condensateur. Ne pas travailler sur cet appareil ni permettre quy soit effectu un travail sans que tous les dispositifs de protection n y soient correctement installs fonctionnants. b. Bien vrifier quil ny ait aucune ouverture sur le coffret qui ne puisse permettre un adulte ou un enfant dy faire pntrer ses doigts et attraper une dcharge lectrique. De telles ouvertures comprendraient sans pour autant sy limiter (1) lespace entre