Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf

上传人:cc518 文档编号:251348 上传时间:2025-10-12 格式:PDF 页数:80 大小:10.92MB
下载 相关 举报
Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf_第1页
第1页 / 共80页
Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf_第2页
第2页 / 共80页
Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf_第3页
第3页 / 共80页
亲,该文档总共80页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-PM11S3v3-int-sm 电路图 维修手册.pdf(80页珍藏版)》请在收音机爱好者资料库上搜索。

1、START:|g1cz3Z09ximWbk6cjE4rRA=|pY1jUgdVDwK9fT3kV73VNPQ1l2zqtMT6gMpFV+PzANo=|PLXqzLbC2dLvdexZ9XDk1w=|:END Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes

2、of improvement, specifications and design are subject to change without notice. Service Manual Integrated Amplifier PM-11S3 /K1G/N1G U1B/N1B PM-11S3 S1232V03DM/DG1603Copyright 2016 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. Ver. 3 Ple

3、ase refer to the MODIFICATION NOTICE. RadioFans.CN 收音机爱 好者资料库 2 CONTENTS ABOUT THIS MANUAL .4 What you can do with this manual .4 Using Adobe Reader (Windows version) .5 SAFETY PRECAUTIONS .7 NOTE FOR SCHEMATIC DIAGRAM .8 NOTE FOR PARTS LIST .8 TECHNICAL SPECIFICATIONS .9 DIMENSION .9 CAUTIONS IN SE

4、RVICING .10 Initializing INTEGRATED AMPLIFIER .10 The layout of this amplifier is well concerned for sound quality. .10 SPECIAL MODE .11 Special mode setting button .11 1. SERVICE MODE .12 2. SERIAL NUMBER CHECK MODE .12 3. ERROR MESSAGES .13 4. PROTECTION MODE .13 WHEN THE MICROPROCESSOR IS REPLACE

5、D WITH A NEW ONE .15 1.The power can not be turned on .17 2.The power can not be turned on .18 3.STANDBY LED FLASHES WHILE USING UNIT .19 4.The power turned on, but a sound does not output normally .19 BLOCK DIAGRAM .21 WIRING DIAGRAM .22 LEVEL DIAGRAM .23 PRINTED WIRING BOARDS .24 SCHEMATIC DIAGRAM

6、S (1/8) .31 bd210121_2 .31 bd210121_3 .32 bd210121_4 .33 bd210121_5 .34 bd110131_2.35 bd11013.36 bd210120_1 .37 bd210120_2 .38 EXPLODED VIEW .39 PARTS LIST OF EXPLODED VIEW .41 PACKING VIEW .45 PARTS LIST OF PACKING & ACCESSORIES .46 SEMICONDUCTORS .47 1. ICs .47 PARTS LIST OF PCB UNIT .56 8U-210121

7、 ASSY .56 8U-110131 ASSY .67 8U-210120A ASSY .76 HDAM-SA3D ASSY .80 RadioFans.CN 收音机爱 好者资料库 3 MARANTZ DESIGN AND SERVICE Using superior design and selected high grade components, marantz company has created the ultimate in stereo sound. Only original marantz parts can insure that your marantz produc

8、t will continue to perform to the specifications for which it is famous. Parts for your marantz equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part number has to be specified. T

9、he following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, ot

10、herwise such part order will be considered as null and void. In case of difficulties, do not hesitate to contact the Technical Department at above mentioned address. 091105DM/DG USA MARANTZ AMERICA, INC 100 CORPORATE DRIVE MAHWAH, NEW JERSEY 07430 USA EUROPE / TRADING D&M EUROPE B. V. P. O. BOX 8744

11、, BUILDING SILVERPOINT BEEMDSTRAAT 11, 5653 MA EINDHOVEN THE NETHERLANDS PHONE : +31 - 40 - 2507844 FAX : +31 - 40 - 2507860 KOREA D&M SALES AND MARKETING KOREA LTD. 2F,YEON BLDG., 88-5, BANPO-DONG, SEOCHO-GU, SEOUL KOREA PHONE : +82 - 2 - 715 - 9041 FAX : +82 - 2 - 715 - 9040 CANADA D&M Canada Inc.

12、 5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1 CANADA PHONE : 905 - 415 - 9292 FAX : 905 - 475 - 4159 JAPAN D&M BUILDING, 2-1 NISSHIN-CHO, KAWASAKI-KU, KAWASAKI-SHI, KANAGAWA, 210-8569 JAPAN D&M Holdings Inc. CHINA D&M SALES AND MARKETING SHANGHAI LTD. ROOM.808 SHANGHAI AIRPORT CITY TERMINAL NO.1

13、600 NANJING (WEST) ROAD, SHANGHAI, CHINA. 200040 TEL : 021 - 6248 - 5151 FAX : 021 - 6248 - 4434 SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins (with unit NOT connecte

14、d to AC mains and its Power switch ON), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer. Ref. UL Stan

15、dard No. 60065. NOTE ON SAFETY : Symbol z Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol z . Any other component substitution (other than original type), may increase risk of fire or electrical shock hazard. 安全上注意: z 部品、安全上重要部品。必指定部品番号使用。

16、RadioFans.CN 收音机爱 好者资料库 4 ABOUT THIS MANUAL Read the following information before using the service manual. What you can do with this manual Search for a Ref. No. (phrase) (Ctrl+Shift+F) You can use the search function in Acrobat Reader to search for a Ref. No. in schematic diagrams, printed wiring

17、board diagrams, block diagrams, and parts lists. 1.Press Ctrl+Shift+F on the keyboard. The Search window appears. Ctrl Shift F 2.Enter the Ref. No. you want to search for in the Search window, and then click the Search button. A list of search results appears. 3.Click an item on the list. The screen

18、 jumps to the page for that item, and the search phrase is displayed. Jump to the target of a schematic diagram connector Click the Ref. No. of the target connector in the red box around a schematic diagram connector. The screen jumps to the target connector. Page magnification stays the same as bef

19、ore the jump. 5 Using Adobe Reader (Windows version) Properties Click this button and check that the printer is set to a suitable paper size. Page to print Select the following checkbox. More Options : Current View Page Sizing & Handling Select the following checkbox. Size / Size Options : Fit Add n

20、otes to this data (Sign) The Sign function lets you add notes to the data in this manual. Save the file once you have finished adding notes. Example using Adobe Reader X On the View menu, click Sign. The Sign pane appears. Example using Adobe Reader 9 On the Document menu, click Sign. Magnify schema

21、tic / printed wiring board diagrams - 1 (Ctrl+Space, mouse operation) Press Ctrl+Space on the keyboard and drag the mouse to select the area you want to view. The selected area is magnified. CtrlSpace 0 When you want to move the area shown, hold down Space and drag the mouse. When you want to show a

22、 full page view, press Ctrl+0 on the keyboard. Print a magnified part of the manual The Properties dialog box and functions will vary depending on your printer. 1. Drag the mouse to magnify the part you want to print. 2. On the File menu, click Print. 3. Configure the following settings in the Print

23、 dialog box. 4. Click the Print button to start printing. 6 Magnify schematic / printed wiring board diagrams - 2 (Pan & Zoom function) The Pan & Zoom function lets you see which part of a magnified diagram is being shown in a separate window. Example using Adobe Reader X On the View menu, point to

24、Zoom, and then click Pan & Zoom. The Pan & Zoom window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Pan & Zoom Window. Magnify schematic / printed wiring board diagrams - 3 (Loupe Tool function) The Loupe Tool function lets you magnify

25、 a specific part of a diagram in a separate window. Example using Adobe Reader X On the View menu, point to Zoom, and then click Loupe Tool. The Loupe Tool window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Loupe Tool Window. 7 SAFETY

26、 PRECAUTIONS The following items should be checked for continued protection of the customer and the service technician. LEAKAGE CURRENT CHECK Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage cu

27、rrent exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if appl

28、icable. CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in th

29、e handling instructions. Cautions concerning electric shock! (1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing

30、 while the set is energized, or by unplugging the power cord when replacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet

31、metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use

32、parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they we

33、re originally placed! For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and hi

34、gh voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area a

35、round. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V in

36、sulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structu

37、ral parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts wit

38、h safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams .Indicated by the z mark. (2) Parts lists .Indicated by the z mark. The use of parts

39、 other than the designated parts could cause electric shocks, fires or other dangerous situations. CAUTION Concerning important safety parts 8 NOTE FOR SCHEMATIC DIAGRAM WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.

40、CAUTION: Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DO NOT return the set to the customer unless the problem is identified and remedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWIS

展开阅读全文