Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf

上传人:cc518 文档编号:252042 上传时间:2025-10-12 格式:PDF 页数:83 大小:27.90MB
下载 相关 举报
Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf_第1页
第1页 / 共83页
Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf_第2页
第2页 / 共83页
Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf_第3页
第3页 / 共83页
亲,该文档总共83页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Pioneer-DDJSX2-djc-sm电路图 维修手册.pdf(83页珍藏版)》请在收音机爱好者资料库上搜索。

1、ORDER NO. PIONEER CORPORATION 1-1, Shin-ogura, Saiwai-ku, Kawasaki-shi, Kanagawa 212-0031, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra

2、Road, #04-01, Singapore 159936 PIONEER CORPORATION2014 2014 Printed in Japan DDJ-SX2 RRV4568 DJ Controller DDJ-SX2 THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). ModelTypePower RequirementRemarks DDJ-SX2SVYXE8AC 100 V to 240 V DDJ-SX2UXECBAC 100 V to 240 V DDJ-SX2FJKLPXE5AC 100 V t

3、o 240 V DDJ-SX2AXE5AC 100 V to 240 V K-MZV OCT. RadioFans.CN 收音机爱 好者资料库 2DDJ-SX2 1234 A B C D E F 1234 SAFETY INFORMATION WARNING This product may contain a chemical known to the State of California to cause cancer, or birth defects or other reproductive harm. Health it is not meant for the casual d

4、o-it- yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the

5、 warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and se

6、rvice technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwhea

7、ds, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120 V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MU

8、ST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtain

9、ed by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Ser

10、vice Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new ins

11、tructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. Leakage current tester Reading should not be above 0.5 mA Device

12、 under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as required) Earth ground AC Leakage Test (FOR USA MODEL ONLY) RadioFans.CN 收音机爱 好者资料库 3DDJ-SX2 5678 5678 A B C D E F CONTENTS SAFETY INFORMATION.2 1. SERVICE PRECAUTIONS.4 1.1 NOTES ON SOLDERING.4 1.2 NO

13、TES ON DSP PCB ASSY.4 2. SPECIFICATIONS.5 3. BASIC ITEMS FOR SERVICE .6 3.1 CHECK POINTS AFTER SERVICING .6 3.2 JIGS LIST.6 3.3 PCB LOCATIONS.7 4. BLOCK DIAGRAM .8 4.1 OVERALL WIRING DIAGRAM .8 4.2 OVERALL BLOCK DIAGRAM.10 5. DIAGNOSIS .12 5.1 TROUBLESHOOTING.12 5.2 OPERATION CHECK WITH Serato DJ .1

14、8 6. SERVICE MODE.21 6.1 SERVICE MODE .21 7. DISASSEMBLY .34 8. EACH SETTING AND ADJUSTMENT.45 8.1 NECESSARY ITEMS TO BE NOTED.45 8.2 UPDATING OF THE FIRMWARE.46 8.3 ITEMS FOR WHICH USER SETTINGS ARE AVAILABLE.47 9. EXPLODED VIEWS AND PARTS LIST.50 9.1 PACKING SECTION.50 9.2 EXTERIOR SECTION .52 10.

15、 SCHEMATIC DIAGRAM.56 10.1 CONTROL PCB ASSY A, B and TRANSFER PCB ASSY.56 10.2 DSP, OUTPUT and BAL. PCB ASSYS.58 10.3 MIX and CR FADER PCB ASSYS.60 10.4 FRONT PCB ASSY .62 10.5 TOUCH PCB ASSY.63 10.6 LED PCB ASSY.64 11. PCB CONNECTION DIAGRAM.66 11.1 CONTROL PCB ASSY A, B and TRANSFER PCB ASSY.66 11

16、.2 DSP, OUTPUT and BAL. PCB ASSYS.70 11.3 MIX and CR FADER PCB ASSYS.74 11.4 FRONT and TOUCH PCB ASSYS .78 11.5 LED PCB ASSY.80 12. PCB PARTS LIST.81 RadioFans.CN 收音机爱 好者资料库 4DDJ-SX2 1234 A B C D E F 1234 1. SERVICE PRECAUTIONS 1.1 NOTES ON SOLDERING 1.2 NOTES ON DSP PCB ASSY For environmental prote

17、ction, lead-free solder is used on the printed circuit boards mounted in this unit. Be sure to use lead-free solder and a soldering iron that can meet specifications for use with lead-free solders for repairs accompanied by reworking of soldering. Compared with conventional eutectic solders, lead-fr

18、ee solders have higher melting points, by approximately 40 C. Therefore, for lead-free soldering, the tip temperature of a soldering iron must be set to around 373 C in general, although the temperature depends on the heat capacity of the PC board on which reworking is required and the weight of the

19、 tip of the soldering iron. Do NOT use a soldering iron whose tip temperature cannot be controlled. Compared with eutectic solders, lead-free solders have higher bond strengths but slower wetting times and higher melting temperatures (hard to melt/easy to harden). The following lead-free solders are

20、 available as service parts: Parts numbers of lead-free solder: GYP1006 1.0 in dia. GYP1007 0.6 in dia. GYP1008 0.3 in dia. For stabilization of power-supply start, the circuitry of the DSP PCB Assy was modified during production. The serial numbers of the DDJ-SX2 units with the DSP PCB Assy before

21、modification are as follows: The modified parts in the circuitry are shown below. The circuit diagram indicated in this service manual is that after modification. All the DSP PCB Assys to be supplied as service parts (Part No.: 704-S1MK2-B090) are modified ones. R498 eliminated R518 added Modified D

22、SP PCB Assy DDJ-SX2/UXECB1 to 18911892 to 2409 DDJ-SX2/SVYXE8None1 to 200 DDJ-SX2/FJKLPXE51 to 900901 to 1600 DDJ-SX2/AXE5All modified Not modifiedR498 eliminatedModel 5DDJ-SX2 5678 5678 A B C D E F 2. SPECIFICATIONS AC adapter Power.AC 100 V to 240 V, 50 Hz/60 Hz Rated current.800 mA Rated output.D

23、C 5 V, 3 A General Main Unit Main unit weight.5.8 kg (12.8 lb) Max. dimensions. 664 mm (W) 70.4 mm (H) 353.4 mm (D) (26.1 in. (W) 2.8 in. (H) 13.9 in. (D) Tolerable operating temperature.+5 C to +35 C (+41 F to +95 F) Tolerable operating humidity.5 % to 85 % (no condensation) Audio Section Sampling

24、rate .44.1 kHz A/D, D/A converter.24 bits Frequency characteristic USB, CD/LINE, MIC1, MIC2.20 Hz to 20 kHz S/N ratio (rated output, A-WEIGHTED) USB.107 dB CD/LINE .96 dB PHONO.87 dB MIC.80 dB Total harmonic distortion (20 Hz 20 kHzBW) USB.0.003 % CD/LINE .0.005 % Standard input level / Input impeda

25、nce CD/LINE . 12 dBu/47 k PHONO. 52 dBu/47 k MIC.57 dBu/3 k Standard output level / Load impedance / Output impedance MASTER OUT 1. +6 dBu/10 k/330 MASTER OUT 2.+2 dBu/10 k/1 k BOOTH OUT. +6 dBu/10 k/330 PHONE.+4 dBu/32 /32 Rated output level / Load impedance MASTER OUT 1.24 dBu/10 k MASTER OUT 2.20 dBu/10 k BOOTH OUT.24 dBu/10 k Crosstalk CD/LINE .82 dB Channel equalizer characteristic HI.26 dB to +6 dB (13 kHz) MID.26 dB to +6 dB (1 kHz) LOW. 26 dB to +6 dB (70 Hz) Input / Output terminals CD input terminal RCA pin jack.2 sets PHONO/LINE input terminals RCA pin jack.