《Marantz-SR7400-avr-mz04019 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Marantz-SR7400-avr-mz04019 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19) Date:5-Mar.-2004Model:SR5400,SR6400,SR7400 Page:1 / 1REF.NBR:MZ04-019 Circulation:Application: Subject: Int.ref: PHENOMENON In idling state, if time passes, the top cover becomes very hot. SOLUTION 1) Idling adjustme
2、nt is changed to the following contents. A. The target setting voltage changes according to ambient temperature. B. Adjustment time and Measurement Voltage after the Power ON are changed. C. Adjustment is impossible when ambient temperature is 9 degrees centigrade or less. 2) The setup of Master Vol
3、ume-Minimum, Speaker out-No load, and Top lid-OPEN does not change. 3) Alignment Point and Measurement Point do not change. 4) Ignore 2 and 3 of Idling Current Alignment on the service manual (SR5400/SR6400 is 59 page and SR7400 is 57 page). Ambient temperature and Measurement Voltage of change are
4、the following table. Ambient temperature 10 to 19 degrees centigrade Ambient temperature 20 to 30 degrees centigrade Measurement Voltage Measurement Voltage 5 min.1.2 mV +- 0.3 mV2.0 mV +- 0.3 mV 10 min.1.2 mV +- 0.3 mV2.1 mV +- 0.3 mV 20 min1.4 mV +- 0.3 mV2.5 mV +- 0.3 mV 30 min1.6 mV +- 0.3 mV2.7
5、 mV +- 0.3 mV 40 min1.7 mV +- 0.3 mV2.9 mV +- 0.3 mV 50 min1.8 mV +- 0.3 mV3.1 mV +- 0.3 mV 60 min.1.9 mV +- 0.3 mV3.2 mV +- 0.3 mV After Turning ON REMARKS -The countermeasure apply to this claim only. -With the Unit which has returned from the customer by repair, Please also readjust the following
6、 serial number. This problem apply to following week code. SR5400 / SR6400 / SR7400 apply to MZ020405xxxxxx. This improvement has been done in the production the week code MZ020406xxxxxx and after. SERVICE BULLETIN By idling, Top cover becomes very hot so that it cannot touch by hand. x for information customer complaint in case of service mandatory . See below RadioFans.CN 收音机爱 好者资料库