1、ORDER NO. PIONEER CORPORATION 1-1, Shin-ogura, Saiwai-ku, Kawasaki-shi, Kanagawa 212-0031, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra

2、Road, #04-01, Singapore 159936 PIONEER CORPORATION2013 2013 Printed in Japan Center SurroundFront HTP-072 RRV4432 HTP-072 and HTP-073 is a Home Cinema Package and consists of VSX-324-K-P, S-22W-P and S-11A-P. THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). Model HTP-072CMXESMAC 120

3、V HTP-072YXE8AC 220 V to 230 V HTP-072, HTP-073VYXE8AC 220 V to 230 V HTP-072DLXEAC 110 V to 127 V/220 V to 240 V HTP-072PWXEAC 220 V to 230 V HTP-072AXQ5AC 220 V VSX-324-K-PCMXESMAC 120 V VSX-324-K-PYXE8AC 220 V to 230 V VSX-324-K-PVYXE8AC 220 V to 230 V VSX-324-K-PDLXEAC 110 V to 127 V/220 V to 24

4、0 V VSX-324-K-PPWXEAC 220 V to 230 V VSX-324-K-PAXQ5AC 220 V S-22W-P S-11A-P TypePower RequirementRemarks AV Receiver Home Cinema Package Home Theater Package VSX-324-K-P HTP-073 HTP-072 Subwoofer S-22W-P Speaker System S-11A-P K-MZV MAY RadioFans.CN 收音机爱 好者资料库 2HTP-072 1234 A B C D E F 1234 SAFETY

5、INFORMATION WARNING This product may contain a chemical known to the State of California to cause cancer, or birth defects or other reproductive harm. Health it is not meant for the casual do-it- yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to

6、properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not

7、risk trying to do so and refer the repair to a qualified service technician. 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit,

8、etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120 V AC 60 H

9、z outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and m

10、echanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special

11、 safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics

12、 as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service

13、 Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. Leakage current tester Reading should not be above 0.5 mA Device under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as required) E

14、arth ground AC Leakage Test (FOR USA MODEL ONLY) RadioFans.CN 收音机爱 好者资料库 3HTP-072 5678 5678 A B C D E F CONTENTS SAFETY INFORMATION.2 1. SERVICE PRECAUTIONS.4 1.1 NOTES ON SOLDERING.4 1.2 NOTES ON REPLACING PARTS.4 1.3 SERVICE NOTICE.4 2. SPECIFICATIONS.5 3. BASIC ITEMS FOR SERVICE .7 3.1 CHECK POIN

15、TS AFTER SERVICING .7 3.2 JIGS LIST.7 3.3 PCB LOCATIONS.8 4. BLOCK DIAGRAM .10 4.1 OVERALL WIRING DIAGRAM .10 4.2 OVERALL BLOCK DIAGRAM.12 4.3 VCC BLOCK DIAGRAM .14 4.4 GND BLOCK DIAGRAM.16 5. DIAGNOSIS .18 5.1 TROUBLESHOOTING.18 5.2 PROTECTION CIRCUIT.23 5.3 IC INFORMATION .24 6. SERVICE MODE.27 7.

16、 DISASSEMBLY .31 7.1 VSX-324-K-P.31 7.2 S-22W-P .35 7.3 S-11A-P.36 8. EACH SETTING AND ADJUSTMENT.37 8.1 UPDATING OF THE FIRMWARE.37 9. EXPLODED VIEWS AND PARTS LIST.42 9.1 PACKING SECTION.42 9.2 VSX-324-K-P.44 9.3 S-22W-P .47 9.4 S-11A-P.48 10. SCHEMATIC DIAGRAM.50 10.1 MAIN ASSY (1/3).50 10.2 MAIN

17、 ASSY (2/3).52 10.3 MAIN ASSY (3/3).54 10.4 OPTCO ASSY .55 10.5 D-MAIN ASSY (1/3).56 10.6 D-MAIN ASSY (2/3).58 10.7 D-MAIN ASSY (3/3).60 10.8 AMP6 ASSY .62 10.9 CPU ASSY.64 10.10 FRONT, INSEL, HP and FUSB ASSYS.66 10.11 CNT ASSY.68 10.12 STBY and V_SEL ASSYS.70 10.13 S-11A-P.72 11. PCB CONNECTION DI

18、AGRAM.74 11.1 MAIN and OPTCO ASSYS.74 11.2 D-MAIN ASSY .78 11.3 AMP6 ASSY .82 11.4 CPU ASSY.84 11.5 FRONT, INSEL, HP and FUSB ASSYS.86 11.6 CNT ASSY.88 11.7 STBY ASSY.89 11.8 V_SEL, G-L, G-T and G-CNT ASSYS.90 12. PCB PARTS LIST.91 RadioFans.CN 收音机爱 好者资料库 4HTP-072 1234 A B C D E F 1234 1. SERVICE PR

19、ECAUTIONS 1.1 NOTES ON SOLDERING 1.2 NOTES ON REPLACING PARTS 1.3 SERVICE NOTICE For environmental protection, lead-free solder is used on the printed circuit boards mounted in this unit. Be sure to use lead-free solder and a soldering iron that can meet specifications for use with lead-free solders

20、 for repairs accompanied by reworking of soldering. Compared with conventional eutectic solders, lead-free solders have higher melting points, by approximately 40 C. Therefore, for lead-free soldering, the tip temperature of a soldering iron must be set to around 373 C in general, although the tempe

21、rature depends on the heat capacity of the PC board on which reworking is required and the weight of the tip of the soldering iron. Do NOT use a soldering iron whose tip temperature cannot be controlled. Compared with eutectic solders, lead-free solders have higher bond strengths but slower wetting

22、times and higher melting temperatures (hard to melt/easy to harden). The following lead-free solders are available as service parts: Parts numbers of lead-free solder: GYP1006 1.0 in dia. GYP1007 0.6 in dia. GYP1008 0.3 in dia. The part listed below is difficult to replace as a discrete component part. When the part listed in the table is defective, replace whole Assy. Assy Name D-MAIN Assy INTERFACE ICIC with heat-padIC2012 D-MAIN 1.2 V Power Supply ICIC with heat-padIC2013 D-MAIN 1.8 V Power Supply I