《Panasonic-SAPM41E-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Panasonic-SAPM41E-cs-sm 电路图 维修手册.pdf(129页珍藏版)》请在收音机爱好者资料库上搜索。
1、n Amplifier Section RMS Output power both channel driven 10%, Total harmonic distortion 1 kHz (Low channel)41 W per channel (6 ) 8 kHz (High channel)39 W per channel (6 ) Total Bi-Amp power80 W per channel Input Impedance250 mV Output Impedance Headphone16 - 32 n FM Tuner Section Frequency range87.5
2、 MHz - 108.0 MHz (50 kHz steps) Sensitivity1.02 V (IHF) S/N 26dB1.00 V Antenna terminal(s)75 (unbalanced) Preset Station15 n AM Tuner Section Frequency range522 kHz - 1629 kHz (9 kHz steps) 520 kHz - 1630 kHz (10 kHz steps) Sensitivity S/N 20 dB (at 999 kHz)900 V/m Preset Station15 n Cassette Deck S
3、ection 2005 Matsushita Electric Industrial Co. Ltd. All rightsreserved.Unauthorizedcopyingand distribution is a violation of law. SA-PM41E SA-PM41EB SA-PM41EG Colour (S). Silver Type Track system4 track, 2 channel Heads Record/playbackSolid permalloy head ErasureDouble gap ferrite head MotorDC servo
4、 motor Recording systemAC bias 100 kHz Erasing systemAC erase 100 kHz Tape speed4.8 cm/s Overall frequency response (+3 dB, -6 dB) at DECK OUT) NORMAL35 Hz - 14 kHz S/N RATIO42.64 dB (A weighted) Wow and flutter0.08% (WRMS) Fast forward and rewind timeApprox. 120 seconds with C-60 cassette tape n CD
5、 Section Disc CD, CD-R, CD-RW, MP38cm / 12cm Sampling frequency CD44.1 kHz MP332 kHz, 44.1 kHz, 48 kHz Bit rate32kbps - 320kbps Decoding16/20/24 bit linear Pick up Beam source/wavelengthSemiconductor laser/780 nm Number of channelsStereo Frequency response20 Hz - 20 kHz (+1dB, -2dB) CD Stereo System
6、 Specification ORDER NO. MD0503061C2 RadioFans.CN 收音机爱 好者资料库 Wow and flutterBelow measurable limit Digital filter8 fs D/A converterMASH (1 bit DAC) n General Power supplyAC 230 V, 50 Hz (For E, EG) AC 230 - 240 V, 50 Hz (For EB) Power consumption130 W Dimensions (W x H x D)175 mm x 254 mm x 391 mm M
7、ass5.8 kg Powerconsumptioninstandby mode 0.6 W 1 Safety Precautions 4 1.1. GENERAL GUIDELINES 4 2 Caution for AC Mains Lead 5 3 Before Repair and Adjustment 6 4 Protection Circuitry 6 5 Handling the Lead-free Solder 6 5.1. About lead free solder (PbF) 6 6 Precaution of Laser Diode 7 7 Handling Preca
8、utions For Traverse Deck 8 8 Accessories 9 9 Operation Procedures 10 10 Information on Disc Typically the melting point is 50 - 70F (30 - 40C) higher. Please use a high temperature soldering iron. In case of soldering iron with temperature control, please set it to 700 20F (370 10C). Pb free solder
9、will tend to splash when heated too high (about 1100F/600C). When soldering or unsoldering, please completely remove all of the solder on the pins or solder area, and be sure to heat the soldering points with the Pb free solder until it melts enough. 6 SA-PM41E / SA-PM41EB / SA-PM41EG 6 Precaution o
10、f Laser Diode Caution : This product utilizes a laser diode with the unit turned ON, invisible laser radiation is emitted from the pick up lens. Wavelength : 780 nm Maximum output radiation power from pick up : 100 W/VDE Laser radiation from pick up unit is safety level, but be sure the followings:
11、1. Do not disassemble the optical pick up unit, since radiation from exposed laser diode is dangerous. 2. Do not adjust the variable resistor on the pick up unit. It was already adjusted. 3. Do not look at the focus lens using optical instruments. 4. Recommend not to look at pick up lens for a long
12、time. ACHTUNG : Dieses Produkt enthlt eine Laserdiode. Im eingeschalteten Zustand wird unsichtbare Laserstrahlung von der Lasereinheit abgestrahlt. Wellenlnge : 780nm Maximale Strahlungsleistung der Lasereinheit :100W/VDE Die Strahlung an der Lasereinheit ist ungefhrlich, wenn folgende Punkte beacht
13、et werden: 1. Die Lasereinheit nicht zerlegen, da die Strahlung an der freigelegten Laserdiode gefhrlich ist. 2. Den werkseitig justierten Einstellregler der Lasereinhit nicht verstellen. 3. Nicht mit optischen Instrumenten in die Fokussierlinse blicken. 4. Nicht ber lngere Zeit in die Fokussierlins
14、e blicken. ADVARSEL : I dette a apparat anvendes laser. CAUTION! THIS PRODUCT UTILIZES A LASER. USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. n Use of Caution Labels 7 SA-PM41E / SA-PM41EB / SA-PM41EG 7 Handl
15、ing Precautions For Traverse Deck The laser diode in the traverse deck (optical pickup) may break down due to potential difference caused by static electricity of clothes or human body. So, be careful of electrostatic breakdown during repair of the traverse deck (optical pickup). Handling of travers
16、e deck (optical pickup) 1. Do not subject the traverse deck (optical pickup) to static electricity as it is extremely sensitive to electrical shock. 2. To prevent the breakdown of the laser diode, an antistatic shorting pin is inserted into the flexible board (FFC board). 3. Take care not to apply e
17、xcessive stress to the flexible board (FFC board). When removing or connecting the short pin, finish the job in as short time as possible. (Fig 7.1) 4. Do not turn the variable resistor (laser power adjustment). It has already been adjusted. Grounding for electrostatic breakdown prevention 1. Work t
18、able grounding. (Fig 7.2) Use the anti-static wrist strap to discharge the static electricity from your body. 2. Work table grounding. (Fig 7.2) Put a conductive material (sheet) or steel sheet on the area where the traverse deck (optical pickup) is place, and ground the sheet. Caution: The static e
19、lectricity of your clothes will not be grounded through the wrist strap. So, take care not to let your clothes touch the traverse deck (optical pickup). Caution when replacing the Traverse Deck The traverse deck has a short point shorted with solder to protect the laser diode against electrostatics
20、breakdown. Be sure to remove the solder from the short point before making connections. (Fig 7.1) (Figs 7.2) 8 SA-PM41E / SA-PM41EB / SA-PM41EG 8 Accessories Note : Refer to Packing Materials It displays it. When the operation which enters the doctor mode in the doctor mode is done, version No. of E
21、EPROM; It is (DEC display) and a check sum (HEX display). 1. Doctor mode ON. 2. pressing C2DF The following are displayed CHECKSUM CHK-EA Note: Version/check sum displays . . . . . . CHK-NO when display when judged that there is EEPROM, and judged it not is. It returns to the doctor mode display of
22、usually by the operation which enters the doctor mode of usually by the operation which enters the doctor mode again with the check sum displayed. (The display does not return by the time limitation) 13.1.4. Cold start setting 1. Doctor mode ON. 2. Press 4 button on the remote control. Data shall be
23、 set in order to make a cold start (backup data are initialized) when reset starts next time. To clarify that the code was accepted at this time, the pattern below is displayed in the LCD for 2 seconds. (Note) In the case that you unplug from AC outlet after this mode was set, then plug to AC again,
24、 a cold start shall begin. And “- - - - - - - - -” is displayed in the FL for 2 seconds. 13.2. Clearing Self-Diagnostic Memory (CD Section) (F15, F17, F22, F26, F27, F28, F29) 52 SA-PM41E / SA-PM41EB / SA-PM41EG 1. Enter into self-diagnostic mode. 2. Errors are stored in the unit memory. To clear me
25、mory, press and hold down STOPn/-DEMO” button for 5 seconds or more during self-diagnostic mode. The message, “CLEAR” appears on the display when memory is erased, and the unit displays the message, “T”. Memory is not affected by turning off the power or unplugging the socket. Be sure to clear memor
26、y after repair is completed. 3. Press STOPn/-DEMO” button. A symbol of self-diagnostic is indicated on the display if an error is found. If several errors are found, a respective indication is displayed when STOPn/-DEMO button is pressing repeatedly. (e.g. H01 CD F15 F01) If no error is found, only
27、T indication is displayed and remains unchange even if STOPn/-DEMO button is pressed. 13.3. Displaying Self-Diagnostic Results (Cassette Deck Section) (H01, H02, H03, F01, F02) 1. Enter the self-diagnostic mode, following the instructions described in 13.1.1 Setting of the Self-Diagnostic Mode. 2. I
28、nsert a normal-positioned music tape with erase prevention niches on both Sides A and B. Press TAPE button to activate the TPS operation so that the tape automatically stops at an interval between music selections. 3. Press STOPn /-DEMO and TAPE buttons together on the remote controller. (Recording
29、does not start.) 4. Then, insert a Cr02-positioned blank cassette tape with an erase prevention niche of Side A or B set to the left side. 5. Press /FF/ button. The tape will be forwarded and automatically stop after two seconds. 6. Remove the cassette tape, and set the other side. 7. Press /REW/ bu
30、tton. The tape will be rewound and automatically stops after two seconds. 8. Press STOPn/-DEMO button on the unit. If an error is found, a self-diagnostic key appears on the display. If several errors are found, the display shows these keys when STOPn/-DEMO button is pressed repeatedly. (Ex.: H01 -
31、H02 - F01 - H01) If no error is found, only the message, “T” appears on the display. (*1) TPS operation (music search) detects the blank sections between music selections. Therefore, do not use tapes with the following conditions: A blank section that lasts only 4 seconds or less. No blank sections
32、(recording through microphones, etc.). Music selections that have extremely low pitches or prolonged silent sections (such as classical music). and/or Music recorded with fade in/out effect. 13.4. Error Code Table 13.4.1. Error code for Power Supply Error CodeAbnormal ItemsPossible Cause F61POWER AM
33、P output abnormal During normal operation, if DCDET becomes “L”, normal POWER OFF process shall not be executed, PCONT shall be switched to “L” immediately. “GOODBYE” shall not be display but the error display F61 is displayed instead. 2 seconds after the F61 displayed, ECONO shall be set to “L” and
34、 FL display shall be turned off. The error content shall be memorized when theabnormality occurs and can be display in the C-mecha self-diagnostic mode described later. 13.4.2. Error codes for CD Mechanism Error CodeAbnormal ItemsPossible Cause F15CD REST SW abnormalCD traverse position intial setti
35、ng operation failsafe counter (1000 ms) waiting for REST SW to turn on. Error No. shall be clear by force or during coldstart. F26CD servo LSI command signal abnormal CD function DTMS command, after system setting, If SENSE = L cannot be detected. Memory shall contain F26 code. After Power on, CD fu
36、nction shall continue, error shall occur “NO DISC”. Error No. shall be clear by force or coldstart. F28DISC LOAD abnormalWhile going to play position, if failsafe counter is finished and switch no change or switch target condition was not achieve, this error shall be memorized. Next time mechanism o
37、perates, it shall do coldstart. Error No. shall be clear by force or coldstart. F29DISC unload abnormalWhile going to play position, if failsafe counter is finished and switch no change or switch target condition was not achieve, this error shall be memorized. Next time mechanism operates, it shall
38、do coldstart. Error No. shall be clear by force or coldstart. 53 SA-PM41E / SA-PM41EB / SA-PM41EG Error CodeAbnormal ItemsPossible Cause F27Slide operation abnormalDuring vertical operation, if failsafe timer is finished and switch no change or switch target condition was not achieve, this error sha
39、ll be memorized. Next time mechanism operates, it shall do coldstart.Error No. shall be clear by force or coldstart. F17Down SW abnormalDuring vertical operation going to the bottom position, if failsafe timer is finished and switch no change or switch target condition was not achieve, this error sh
40、all be memorized. The Next time mechanism operates, it shall do mechanism initialization.Error No. shall be clear by force or coldstart. F22Loading Mode / Mecha abnormal During mecha initialization, Loading mode mechanism abnormal, normal operation cannot be achieve. The next time mechanism operates
41、, it shall do mechanism initialization.Error No. shall be clear by force or coldstart. 13.4.3. Error codes for Deck Mechanism Error CodeAbnormal ItemsPossible Cause H01MODE SW abnormalNormal operation during mecha transition, MODE SW abnormal is memorised. The content of abnormality can be confirmed
42、 in the abnormal detection mode explained in the later section. H02REC INH SW abnormal The content of abnormality can be confirmed in the abnormal detection mode explained in the later section. H03HALF SW abnormal F01Reel pulse abnormal F02TPS abnormal 13.5. Deck Mechanism Self-Diagnostic Mode 1. A
43、Cr02-positioned blank cassette tape with an erase prevention niche on either Side A or B. 2. A normal-positioned music tape with erase prevention niches on both Sides A and B. Both tapes are halfway forwarded in advance. 3. The remote controller that comes with this unit. No.Operation ProceduresMico
44、n operation H: Tri-State 5SPOUTOSpindle driver output signal 6SPPOLOSpindle driver output signal 7TRVPOSpindle driver output signal 8TRVMOSpindle driver output signal 9TRVP2OTraverse driver output signal 2 (+) 10TRVM2OTraverse driver output signal 2 (-) 11TRPOTraverse driver output signal (+) 12TRMO
45、Traverse driver output signal (-) 13FOPOTraverse driver output signal (+) 14FOMOTraverse driver output signal (-) 15IOVDD3-I/O power supply 3 16DVDD1-Power supply 1 for digital circuit 17DVSS1-Digital circuit GND 1 18ADPVCCIPower voltage monitor. Power voltage input 19TEINIDSP traverse error signal
46、input 20FEINIDSP focus error signal input 21CEAI/OHPF-Amp capacitance connection terminal 22RFENVORF envelope signal monitor 23FEOUTOFE Amp output 24FENIFE Amp reversal input 25TENITE Amp reversal input 26TEOUTOTE Amp output 27VREFOVREF output 28PDIAPC Amp input 29LDOAPC Amp output 30EITracking inpu
47、t signal 1 31FITracking input signal 2 32DITracking input signal 4 33BITracking input signal 2 34CITracking input signal 3 35AIFocus input signal 1 36DCDETIDetection HPF capacitance terminal 37RFVDD-RF Amp power supply Pin No.MarkI/OFunction 1IN2IMotor Driver 92 Input 2PC2ITurntable Motor Drive Sign
48、al (“L”: ON) 3IN1IMotor Driver (1) Input 4PC1-Traverse Motor Drive Signal (“L”:ON) 5N.C.-No Connection 6N.C.-No Connection Pin No.MarkI/OFunction 38RESERVE-AVSS2 39RFOUTORF Amp output 40RFINIAGC input 41CAGCI/OAGC control terminal 42ARFOUTOAGC output (Audio RF) 43AVSS2-Analog circuit GND 2 44ARFINIR
49、F signal input 45DSLFODSL loop filter 46IREFII (current), Reference input 47PLLFOPLL loop filter 48PLLF0OPLL loop filter 49AVDD2-Analog circuit power supply 2 50OUTLOLCH output signal 51AVSS1-Audio output circuit GND 1 52N.C.-No Connection 53AVDD1-Power supply 1 for analog circuit 54OUTRORCH output signal 55DVSS2-Digital circuit GND 2 56IOVDD1-I/O power supply 1 57DVDD2-Power supply 2 for Digital circuit 58REGONILaser diode control (H: ON) 59IOMODEII/O switching setting input 60NTESTITest m