1、1/8 AVR-2310 Setup Tool (0.0.16) Manual DENON Oct.29.2009 RadioFans.CN 收音机爱 好者资料库 2/8 Table of contentsTable of contents 1 Instruction Manual 1.1 Stand alone mode 1.2 Communication mode 1.2.1 Top Menu & System Setup 1.2.2 Surround Parameter 1.2.3 Load/Save Full Setup 1) Minimum hardware and software

2、 requirements: Type PC/AT compatible CPU Intel Pentium/P3 1GHz or faster RAM 256MB or more Free hard disc space 25MB or more OS Windows XP Home Edition / Professional SP2 or more Display resolution XGA (1024x768) or more. Port. RS-232C Communication speed 115,200bps Connection Cable D-sub 9Pin(mail

3、femail), Straight 2) Installation procedure a. Execute AVR2310_SystemSetup_0.0.16(for_Windows_XP).exe (= for Windows XP) or AVR2310_SystemSetup_0.0.16(for_Windowx_Vista).exe (= for Windows Vista) (Install the AVR-2310 Setup Tool and necessary files) b. Execute AVR-2310 Setup Tool. Ex. Start of Windo

4、ws - Program - AVR2310_SystemSetup RadioFans.CN 收音机爱 好者资料库 3/8 1 Instruction 1 Instruction 1.11.1 Stand alone mode Stand alone mode This mode enables the setting data concerning the product to be made with PC beforehand. (1) Select “Stand alone” by the connection port setting. (2) Select “Model name

5、” by the Model setting. (3) Firmware update. (4) Select System Setup menu and set parameters. Load Param. ButtonLoad Param. Button : The setup parameter can be loaded from the file in PC. Save Param. ButtonSave Param. Button : Edited setup parameter can be saved to the file. ETC Setup-Surround Param

6、eter : The surround mode and the parameter can be set to each input function.(see page6) Hidden Setup MenuHidden Setup Menu : When this item is checked, system setup can not operate. NOTE NOTE *Real Time Control cannot be used. *Load/Save Full Setup of ETC Setup cannot be used. *Channel level settin

7、g of Speaker Setup (2) and Surround Parameter may be over write the results of Auto setup. () () RadioFans.CN 收音机爱 好者资料库 4/8 1.2 Communication mode 1.2.1 Top Menu & System Setup 1.2 Communication mode 1.2.1 Top Menu & System Setup This mode enables the control of the product from the PC via RS-232C

8、cable. (1) Select “COM 1-16” by the connection port setting. (2) “Model name” is set automatically. Get the all Setting Data from AVR-2310 and copy to the Edit Data ButtonGet the all Setting Data from AVR-2310 and copy to the Edit Data Button : All setup parameter of System Setup can be loaded from

9、the AVR2310 connected via RS-232C, and then those parameters copy to the edit data. Send the all Setting Data to AVR-2310 ButtonSend the all Setting Data to AVR-2310 Button : All edited setup parameter of System Setup can be set to the AVR2310 connected via RS-232C. 5/8 (3) Firmware update. If the f

10、irmware of the product is older version for this setup tool, following window would be appeared at operation (2). Click button (1) and update firmware of the product. It takes about 20 minutes to update firmware. Dont turn off the power for the product while updating firmware. If you turn off the po

11、wer for the product or unplug RS-232C cable while updating firmware , it may cause damage on the product. Please take care for this operation. () 6/8 (4) Select System Setup menu and set parameters. Setting Category EditEdit : now editing. , AVR/AVCAVR/AVC : setting data of the AVR2310 connected via

12、 RS-232C.(Not edit) DefaultDefault : Default setting. (Not edit) Copy AVR-2310 to Edit Data ButtonCopy AVR-2310 to Edit Data Button : Setup parameter on selected page can be loaded from the AVR2310 connected via RS-232C, and then those parameters copy to the edit data. Copy Default to Edit Data Butt

13、onCopy Default to Edit Data Button : Default setting data can be copied to the edit data of selected page. Send the setup data on this page ButtonSend the setup data on this page Button : Edited setup parameter on selected page can be set to the AVR2310 connected via RS-232C. 7/8 1.2.2 Surround Para

14、meter of ETC Setup 1.2.2 Surround Parameter of ETC Setup Load the Surround Parameter from File ButtonLoad the Surround Parameter from File Button : The surround parameter can be loaded from the file in PC. Save the Surround Parameter to File ButtonSave the Surround Parameter to File Button : The edi

15、ted surround parameter can be saved to the file. Set the Surround Parameter to AVR-2310 ButtonSet the Surround Parameter to AVR-2310 Button : Edited surround parameter can be set to the AVR2310 connected via RS-232C. 8/8 1.2.3 Load/Save Full Setup of ETC Setup 1.2.3 Load/Save Full Setup of ETC Setup

16、 Get Full Setup Data from AVR-2310 (and File Save) ButtonGet Full Setup Data from AVR-2310 (and File Save) Button : All backup data can be loaded from the AVR2310 connected via RS-232C, and then those data can be saved to the PC. Set Full Setup Data to AVR-2310 ButtonSet Full Setup Data to AVR-2310 Button : All backup data can be set to the AVR2310 connected via RS-232C.