《NAD-C541-cd-si1 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《NAD-C541-cd-si1 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Service Information 541/541i PROBLEM: You may have a complaint about an odour coming from the cd player after it has been turned on for a while. CAUSE: The rubber pad securing the toroid transformer is warming up slightly and emitting an odour from the unit. SOLUTION: Replace the existing rubber pa
2、d with a new pad. The part number for this new pad is C541/C541I TRANS PAD. The existing pad will in no way have any effect on the transformers performance or safety issues, aside from this odour. The new pad when installed will not have this odour. PRODUCTION: The serial numbers of the affected models are C541- G18C54108001 - G1XC54110600 C541i G1ZC541I00001 - G1ZC541I01800 Contact: NAD Electronics International 633 Granite Court Pickering, ON Canada L1K 3K1 Voice: 905-831-0799 FAX 905-837-6357 RadioFans.CN 收音机爱 好者资料库