《NAD-C350-int-cc2 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《NAD-C350-int-cc2 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
Service Information C350 Circuit Change PROBLEM: The standby transformer voltage is dropping or unit wont turn on from standby mode. CAUSE: Capacitors C511,C512 and C513 are shorting. SOLUTION: Change C511,C512 and C513 from 100nF/100v ceramic disc to 100nF/100v metallized polyester film. PRODUCTION: This change has been implemented in production from serial number:H1YC35017612 Contact: NAD Electronics International 633 Granite Court Pickering, ON Canada L1K 3K1 Voice: 905-831-0799 FAX 905-837-6357 RadioFans.CN 收音机爱 好者资料库