《Nad-T-533-AH-Service-Manual(1) 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Nad-T-533-AH-Service-Manual(1) 电路图 维修手册.pdf(79页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL SERVICE MANUAL T533CT/T533C/T513CT/ T513C/T533AH/T513AH DVD VIDEO PLAYER MODELS : T533CT/T533C/T513CT/T513C/T533AH/T513AHSERVICE MANUAL NAD 2003 NAD ELECTRONICS INTERNATIONAL TORONTO T533CT/T533C/T513CT/ T513C/T533AH/T513AH DVD VIDEO PLAYER T533CT/T533C/T513CT/ T513C/T533AH/T513AH DVD
2、 VIDEO PLAYER RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 1-11-1 SECTION 1 SUMMARY CONTENTS PRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS. 1-2 SERVICING PRECAUTIONS. 1-3 General Servicing Precautions Insulation Checking Prodedure Electrostatically Sensitive Devices SPECIFICATIONS. 1-4 R
3、adioFans.CN 收音机爱 好者资料库 1-2 CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY, NEVER PERFORM CUSTOMIZED INSTALLATIONS WITHOUT MANUFAC- TURERS APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANY RESULTING PROPERTY DAMAGE OR USER INJU
4、RY. SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARE THOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETY CHECKS AND SERVICING GUIDELINES. TO DO OTHERWISE, INCREASES THE RISK OF POTENTIAL HAZARDS AND INJURY TO THE USER. WHILE SERVICING, USE AN ISOLATION TRANSFORMER FOR PROTEC- TION FROM A.C. LINE
5、 SHOCK. SAFETY CHECKS AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRCTED. A CHECK SHOULD BE MADE OF THE FOLLOWING. SUBJECT : FIRE CONNECT A 1500 OHM 10 WATT RESIS- TOR, PARALLELED BY A .15 MFD. 150.V A.C TYPE CAPACITOR BETWEEN A KNOWN GOOD EARTH GROUND (WATER PIPE, CON- DUIT, ETC.) AND THE EXPOSED
6、 METALLIC PARTS, ONE AT A TIME. MEASURE THE A.C. VOLTAGE ACROSS THE COMBINATION OF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUG AND REPEAT A.C. VOLTAGE MEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURED MUST NOT EXCEED 75 VOLTS R.M.S. THIS CORRESPONDS TO 0.5 MILLIAMP A.C
7、 ANY VALUE EXCEEDING THIS LIMIT CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED IMMEDIATELY. SUBJECT: GRAPHIC SYMBOLS THE LIGHTNING FLASH WITH APROWHEAD SYMBOL. WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” TH
8、AT MAY BE OF SUFFICIENT MAG- NITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK. THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIAN- GLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION IN SERVICE LITERATURE. SUBJECT : X-RADIATION 1. BE SURE PROCEDURES AND INSTRUC
9、TIONS TO ALL SERVICE PER- SONNEL COVER THE SUBJECT OF X-RADIATION. THE ONLY POTEN- TIAL SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PIC- TURE TUBE. HOWEVER, THIS TUBE DOES NOT EMIT X-RAYS WHEN THE HIGH VOLTAGE IS AT THE FACTORY SPECIFIED LEVEL. THE PROPER VALUE IS GIVEN IN THE APPLICABLE SCHEM
10、ATIC. OPERA- TION AT HIGHER VOLTAGES MAY CAUSE A FAILURE OF THE PIC- TURE TUBE OR HIGH VOLTAGE SUPPLY AND, UNDER CERTAIN CIR- CUMSTANCES, MAY PRODUCE RADIATION IN EXCESS OF DESIR- ABLE LEVELS. 2. ONLY FACTORY SPECIFIED C.R.T. ANODE CONNECTORS MUST BE USED. DEGAUSSING SHIELDS ALSO SERVE AS X-RAY SHIE
11、LD IN COLOR SETS, ALWAYS RE-INSTALL THEM. 3. IT IS ESSNTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE AN ACCURATE AND RELIABLE HIGH VOLTAGE METER. THE CALIBRA TION OF THE METER SHOULD BE CHECKED PERIODICALLY AGAINST A REFERENCE STANDARD, SUCH AS THE ONE AVAILABLE AT YOUR DISTRIBUTOR. 4. WHEN THE HIGH VO
12、LTAGE CIRCUITRY IS OPERATING PROPERLY THERE IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERY TIME A COLOR CHASSIS IS SERVICED. THE BRIGHTNESS SHOULD BE RUN UP AND DOWN WHILE MONITORING THE HIGH VOLTAGE WITH A METER TO BE CERTAIN THAT THE HIGH VOLTAGE DOES NOT EXCEED THE SPECIFIED VALUE AND THAT IT
13、 IS REGULATING CORRECTLY, WE SUGGEST THAT YOU AND YOUR SERVICE ORGA- NIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE REGU- LATION IS ALWAYS CHECKED AS A STANDARD SERVICING PROCE- DURE. AND THAT THE HIGH VOLTAGE READING BE RECORDER ON EACH CUSTOMERS INVOICE. 5. WHEN TROUBLESHOOTING AND MAKING TEST ME
14、ASUREMENTS IN A PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE, AVOID BEING UNNECESSARILY CLOSE TO THE PICTURE TUBE AND THE HIGH VOLTAGE SUPPLY. DO NOT OPERATE THE PRODUCT LONGER THAN IS NECESSARY TO LOCATE THE CAUSE OF EXCES SIVE VOLTAGE. 6. REFER TO HV. B+ AND SHUTDOWN ADJUSTMENT PROCEDURES DESC
15、RIBED IN THE APPROPRIATE SCHEMATIC AND DIAGRAMS (WHERE USED). SUBJECT: IMPLOSION 1. ALL DIRECT VIEWED PICTURE TUBES ARE EQUIPPED WITH AN INTE GRAL IMPLOSION PROTECTION SYSTEM, BUT CARE SHOULD BE TAKEN TO AVOID DAMAGE DURING INSTALLATION, AVOID SCRATCHING THE TUBE. IF SCRATCHED REPLACE IT. 2. USE ONL
16、Y RECOMMENDED FACTORY REPLACEMENT TUBES. SUBJECT : TIPS ON PROPER INSTALLATION 1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBY- HOLE OR CLOSELY FITTING SHELF SPACE. OVER OR CLOSE TO HEAT DUCT, OR IN THE PATH OF HEATED AIR FLOW. 2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS: OUTDOOR PATIO IN
17、STALLATIONS WHERE DEW IS A FACTOR, NEAR STEAM RADIA- TORS WHERE STEAM LEAKAGE IS A FACTOR, ETC. 3. AVOID PALCEMENT WHERE DRAPERIES MAY OBSTRUCT REAR VENTING. THE CUSTOMER SHOULD ALSO AVOID THE USE OF DEC- ORATIVE SCARVES OR OTHER COVERINGS WHICH MIGHT OBSTRUCT VENTILATION. 4. WALL AND SHELF MOUNTED
18、INSTALLATIONS USING A COMMER- CIAL MOUNTING KIT. MUST FOLLOW THE FACTORY APPROVED MOUNTING INSTRUCTIONS A PRODUCT MOUNTED TO A SHELF OR PLATFORM MUST RETAIN ITS ORIGINAL FEET (OR THE EQUIVALENT THICKNESS IN SPACERS) TO PROVIDE ADEQUATE AIR FLOW ACROSS THE BOTTOM, BOLTS OR SCREWS USED FOR FASTENERS M
19、UST NOT TOUCH ANY PARTS OR WIRING. PERFORM LEAKAGE TEST ON CUSTOMIZED INSTALLATIONS. 5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF A PRODUCT ON SLOPING SHELF OR A TILTED POSITION, UNLESS THE PRODUCT IS PROPERLY SECURED. 6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLE ON ITS MOUNTING TO THE CART. C
20、AUTION THE CUSTOMER ON THE HAZ- ARDS OF TRYING TO ROLL A CART WITH SMALL CASTERS ACROSS THRESHOLDS OR DEEP PILE CARPETS. 7. CAUTION CUSTOMERS AGAINST THE USE OF A CART OR STAND WHICH HAS NOT BEEN LISTED BY UNDERWRITERS LABORATORIES, INC. FOR USE WITH THEIR SPECIFIC MODEL OF TELEVISION RECEIVER OR GE
21、NERICALLY APPROVED FOR USE WITH T.V.S OF THE SAME OR LARGER SCREEN SIZE. 8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSION CORDS, EXPLAIN THAT A FOREST OF EXTENSIONS SPROUTING FROM A SIN- GLE OUTLET CAN LEAD TO DISASTROUS CONSEQUENCES TO HOME AND FAMILY. PRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO
22、 PRODUCTS A.C. VOLTMETER GOOD EARTH GROUND SUCH AS THE WATER PIPE. CONDUIT. ETC PLACE THIS PROBE ON EACH EXPOSED METAL PART 1-3 SERVICING PRECAUTIONS CAUTION : Before servicing the DVD covered by this service data and its supplements and addends, read and follow the SAFETY PRECAUTIONS. NOTE : if unf
23、oreseen circum- stances create conflict between the following servicing pre- cautions and any of the safety precautions in this publica- tions, always follow the safety precautions. Remembers Safety First: General Servicing Precautions 1. Always unplug the DVD AC power cord from the AC power source
24、before: (1)Removing or reinstalling any component, circuit board, module, or any other assembly. (2)Disconnection or reconnecting any internal electrical plug or other electrical connection. (3)Connecting a test substitute in parallel with an elec- trolytic capacitor. Caution : A wrong part substitu
25、tion or incorrect polarity installation of electrolytic capacitors may result in an explosion hazard. 2. Do not spray chemicals on or near this DVD or any of its assemblies. 3. Unless specified otherwise in this service data, clean electrical contacts by applying an appropriate contact cleaning solu
26、tion to the contacts with a pipe cleaner, cotton-tipped swab, or comparable soft applicator. Unless specified otherwise in this service data, lubrication of contacts is not required. 4. Do not defeat any plug/socket B+ voltage interlocks with whitch instruments covered by this service manual might b
27、e equipped. 5. Do not apply AC power to this DVD and/or any of its electrical assemblies unless all solid-state device heat sinks are cerrectly installed. 6. Always connect test instrument ground lead to the appropriate ground before connection the test instrument positive lead. Always remove the te
28、st instrument ground lead last. Insulation Checking Procedure Disconnect the attachment plug from the AC outlet and turn the power on. Connect an insulation resistance meter(500V) to the blades of the attachment plug. The insulation resis- tance between each blade of the attachment plug and acces- s
29、ible conductive parts (Note 1) should be more than 1M- ohm. Note 1 : Accessible Conductive Parts including Metal pan- els, Input terminals, Earphone jacks, etc. Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such compone
30、nts commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field effect transistors and semiconductor chip components. The following techniques should be used to help reduce the incidence of component damage caused by static elec
31、tricity. 1. Immediately before handling any semiconductor compo- nent or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commer- cially available discharging wrist strap device, which should be remove
32、d for potential shock reasons prior to applying power to the unit under test. 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly. 3. Use only a groune
33、d-tip soldering iron to solder or unsolder ES devices. 4. Use only an anti-static solder removal device. Some solder removal devices not classified a “anti-static” can generate electrical charges sufficient to damage ES devices. 5. Do not use freon-propelled chemicals. These can generate electrical
34、charge sufficient to damage ES devices. 6. Do not remove a replacement ES device from its protec tive package until immediately before you are ready to install it. (Most replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil, or comparable cond
35、uctive material). 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly into which the device will be installed. Caution : Be sure no power is applied to the chassis or circuit, and observe a
36、ll other safety precautions. 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Normally harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static elec- tricity sufficient to damage an ES devic
37、e.) 1-4 SPECIFICATIONS GENERAL Power requirementsAC 120V, 60Hz(T533AH/T513AH), AC 110240V, 50/60Hz(T533CT/T533C/T513CT/T513C) Power consumption14W Dimensions(approx.)430 x 69 x 230mm (16.9 x 2.4 x 9.5 inches) (W/h/d) Mass(approx.)2.4kg (5.3 lbs) Operating temperature5C to 35C (41F to 95F) Operating
38、humidity5% to 9% SYSTEM LaserSemiconductor laser, wavelength 650nm Signal systemNTSC, PAL Frequency responseDVD (PCM 96kHz): 2Hz to 44kHz DVD (PCM 48kHz): 2Hz to 22kHz CD: 2Hz to 20kHz Signal-to-noise ratioMore than 100dB (ANALOG OUT connectors only) Harmonic distortionLess than 0.008% Dynamic range
39、More than 100dB(DVD) More than 95dB(CD) OUTPUTS VIDEO OUTPUTS1V p-p, 75 , sync negative, RCA jack x 1 S-V IDEO OUTPUTS(Y)1.0V(p-p), 75, negative sync., Mini DIN 4-pin x 1 (C)0.3V(p-p), 75 COMPONENT VIDEO OUT(Y)1.0V(p-p), 75, negative sync., RCA jack x 1 (Pb)/(Pr)0.7V(p-p), 75, RCA jack x 2 Audio out
40、put(digital audio)0.5V(p-p), 75, RCA jack X 1 Audio output(optical audio)5V (p-p), 75, Optical connector x 1 Audio output(analog audio)2.0Vrms (1kHz, 0dB), 600, RCA jack (L, R) x 1 2-1 SECTION 2 CABINET & MAIN CHASSIS CONTENTS 1. EXPLODED VIEWS.2-2 1. Cabinet and Main Frame Section.2-2 2. Packing Ac
41、cessory Section.2-3 2-2 EXPLODED VIEWS 1. Cabinet and Main Frame Section 463 463 250 A00 463 463 300 283 280 A42 A49 A47 A48 A44 A43 A46 260 261 261 463 320 463 467 463 465 452 SCART&5.1CH MODEL ONLY A 5 4 3 2 1 BCD 2. Packing Accessory Section BATTERY808 PACKING SHEET804 PACKING OPTIONAL PARTS 803
42、806 820 OWNERS MANUAL RF CABLE 810 CABLE SET ASSY 801 REMOCON900 BOX CARTON802 PACKING803 811 812 PLUG ASSY 1WAY(YELLOW) PLUG ASSY 1WAY(BLACK) PLUG ASSY 2WAY 2-3 3-1 SECTION 3 ELECTRICAL CONTENTS ELECTRICAL TROUBLESHOOTING GUIDE.3-2 1. Power check flow.3-2 2. System operation flow .3-3 3. Test & deb
43、ug flow.3-4 DETAILS AND WAVEFORMS ON SYSTEM TEST AND DEBUGGING.3-10 1. SYSTEM 27MHz CLOCK,RESET,FLASH R/W SIGNAL .3-10 2. SDRAM CLOCK.3-12 3. TRAY OPEN/CLOSE SIGNAL.3-12 4. SLED CONTROL RELATED SIGNAL (NO DISC CONDITION).3-14 5. LENS CONTROL RELATED SIGNAL(NO DISC CONDITION).3-14 6. LASER POWER CONT
44、ROL RELATED SIGNAL(NO DISC CONDITION).3-15 7. DISC TYPE JUDGEMENT WAVEFORM.3-15 8. FOCUS ON WAVEFORM.3-17 9. SPINDLE CONTROL WAVEFORM (NO DISC CONDITION).3-18 10. TRACKING CONTROL RELATED SIGNAL(System checking).3-19 11. RF WAVEFORM .3-20 12. MT1379 AUDIO OPTICAL AND COAXIAL OUTPUT (ASPDIF).3-20 13. MT1379 VIDEO OUTPUT WAVEF