《Bose-502-eq-sup 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bose-502-eq-sup 电路图 维修手册.pdf(1页珍藏版)》请在收音机爱好者资料库上搜索。
1、402, 502, 802 II Controllers Unbalanced output connection diagrams Immediately The unbalanced output connection diagrams shown in these manuals are incorrect. For barrier strip connectors: The shield and ground wires MUST connect to the ground terminal for the output connections, not the negative te
2、rminal. See Figure 1 for reference. For XLR connectors: The shield and ground wires MUST connect to pin 1 for the output connections, not pin 3. Pin 3 is unconnected, not Pin 1. See Figure 1 for reference. Figures affected: Figure 24, 402/802 II Controller Service Manual, P/N 174785. Figure 19, 502 (Panaray) Service Manual, P/N 170310. Figure 1. Corrected Unbalanced Output Connection Diagrams OUTPUT Hot (+) pin 2 Shield and ground pin 1 Unconnected pin 3 To unbalanced input on amplifier Hot (+) Shield/ground To unbalanced input on amplifier 183606 RadioFans.CN 收音机爱 好者资料库