《RCA-RP1610B-pr-sch 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《RCA-RP1610B-pr-sch 电路图 维修手册.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。
1、? ? ? ? Latin America After Sales Indianapolis IN 46290 U.S.A. ? ? ? ? ? ? ? ? ? ? ? ? ?!?#?$?% ? ?#?$? ? ?# ? ? ? ? ? ? ? ? ? ? ? ?! ? ? ?!#$%!? ?&??(?)?# RadioFans.CN 收音机爱 好者资料库 1-4 ? ? ? RadioFans.CN 收音机爱 好者资料库 SAFETY PRECAUTIONS 1. Before returning the instrument to the customer, always make a
2、 safety check of the entire instrument, including, but not limited to, the following items: a. Be sure that no built-in protective devices are defective and/ or have been defeated during servicing. (1) Protective shields are provided on this instrument to protect both the technician and the customer
3、. Correctly replace all missing protective shields, including any removed for servicing convenience. (2) When reassembling the instrument, be sure to put back in place all protective devices, including, but not limited to, nonmetallic control knobs, insulating fishpapers, adjustment and compartment
4、covers/shields, and isolation resistor/capacitor networks. Do not operate this instrument or permit it to be operated without all protective devices correctly installed and functioning. Servicers who defeat safety features or fail to perform safety checks may be liable for any resulting damage, and
5、may expose themselves and others to possible injury. b. Be sure that there are no cabinet openings through which an adult or child might be able to insert their fingers and contact a hazardous voltage. Such openings include, but are not limited to, (1) excessively wide cabinet ventilation slots, and
6、 (2) improperly fitted and/or incorrectly secured cabinet covers. c. Leakage Cold Check - With the instrument AC plug removed from any AC source, connect an electrical jumper across the two AC plug prongs. Place the instrument AC switch in the on position. Connect one lead of an ohmmeter to the AC p
7、lug prongs tied together and touch the other ohmmeter lead in turn to each push button/customer control, exposed metal screws, metallized overlays and to each cable connector. If the measured resistance is less than 1.0 megohm or greater than 5.2 megohm an abnormality exists that must be corrected b
8、efore the instrument is returned to the customer. Repeat this test with the AC switch in the off position. d. Leakage Current Hot Check On completely assembled instrument, plug the AC line cord directly into a 120V AC outlet. (Do not use an isolation transformer during this test.) Use a leakage curr
9、ent tester or a metering system that complies with American National Standards Institute (ANSI) C101.1 Leakage Current for Appliances and Underwriters Laboratories (UL) 1492 (Section 67). Measure for current from a known earth ground (metal waterpipe, conduit, etc.) to all exposed metal or conductiv
10、e parts of the instrument (antenna connections, handle bracket, metal cabinet, screwheads, metallic overlays, push-buttons, control shafts, etc.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5 milliamp. Reverse the in
11、strument power cord plug in the outlet and repeat the test. ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE INSTRUMENT TO THE CUSTOMER OR BEFORE CONNECTING TO ANTENNA OR ACCESSORIES. e. Interconnected Equipment AC
12、 Leakage Test Avoid shock hazards. The instrument, accessory, or cable(s) to which this instrument is connected should have the applicable sections of the leakage resistance cold check and the leakage current hot check performed. Do not connect this instrument to an antenna, cable or accessory that
13、exhibits excessive leakage currents. 2. Read and comply with all caution and safety-related notes on or inside the instrument cabinet, and on the chassis. 3. Design Alteration Warning - Do not alter or add to the mechanical or electrical design of this instrument. Design alterations and additions, i
14、ncluding, but not limited to, circuit modifications and the addition of items such as auxiliary audio output connections, cables and accessories, etc., might alter the safety characteristics of this instrument and create a hazard to the user. Any design alterations or additions will void the manufac
15、turers warranty and will make you, the servicer responsible for personal injury or property damage resulting therefrom. 4. Observe original lead dress. Take extra care to assure correct lead dress in the following areas: (a) near sharp edges, (b) near thermally hot parts - be sure that leads and com
16、ponents do not touch thermally hot parts, and (c) the AC supply. Always inspect in all areas for pinched, out-of-place, or frayed wiring. Do not change spacing between components and the printed-circuit board. Check AC power cord for damage. 5. Components, parts and/or wiring that appear to have ove
17、rheated or are otherwise damaged should be replaced with components, parts or wiring that meet original specifications. Additionally, determine the cause of overheating and/or damage and, if necessary, take corrective action to remove any potential safety hazard. 6. PRODUCT SAFETY NOTICE - Many elec
18、trical and mechanical parts have special safety-related characteristics, some of which are often not evident from visual inspection, nor can the protection they give be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts that have special safety characteristics a
19、re identified in this service data by a ( ! ) on schematics and in the parts list. Use of a substitute replacement that does not have the same safety characteristics as the recommended replacement part in this service data parts list might create shock, fire and/or other hazards. Product Safety is u
20、nder review continuously and new instructions are issued whenever appropriate. For the latest information, always consult the appropriate current service literature. 1-2 RadioFans.CN 收音机爱 好者资料库 BEFORE REPLACING PARTS, READ THE FOLLOWING: REPLACEMENT PARTS Warranty Status of Assemblies and Parts - Al
21、l assemblies and components shown in this part list are eligible for warranty exchange or replacement except those with a dot shown to the left of the Description. Assemblies and components with a dot to the left of the Description are NOT eligible for warranty exchange or replacement. Warranty repl
22、acement of cabinet parts requires the approval of a Thomson Consumer Electronics Field Service Manager. Warranty Status and Specifications of assemblies and components are subject to change without notice. Consult the TCE Parts Pricing Microfiche for the latest warranty status information. Approved
23、Substitute Stock Numbers - Before ordering stock numbers in the part list, look for an approved substitute stock number in the current Price Schedule. This will minimize your service time and avoid ordering parts you already have in stock. NOTE: When ordering components that are listed more than onc
24、e in this part list, always adhere to the serial number application guidelines given in the description column. If a serial number application guideline is not given, always select the component with a value, rating, other specification or identification marking(s) that match those of the correspond
25、ing component in the instrument you are servicing. PRODUCT SAFETY NOTE: Components marked with a critical safety symbol have special characteristics important to safety. Before replacing any of these components, carefully read the PRODUCT SAFETY NOTICE in the basic service data. Do not degrade the s
26、afety of the set through improper servicing. Although assemblies as a whole may not be marked with a critical safety symbol , replacement of assemblies with other assemblies not approved may result in a safety hazard. 1 - 3 Septembe 1999 RP1610B Critical Safety Symbol Not Eligible For Warranty Stock
27、SymbolDescriptionDrawingSymbolStockDescriptionDrawing RP-1610B CABINET ASY CAB98A32583CABINET FRONT5003632010 CAB98A32584CABINET BACK5023632010 CLI3A32590CLIP BELT5563632010 CON2A31040CONTACT BATTERY +6613610010 CON2A31042CONTACT BATTERY +/-6613610030 CON2A31041CONTACT BATTERY -6613610020 DIA90A3258
28、9DIAL POINTER5393632010 DOO9A32585DOOR BATTERY5103632010 KNO43A32587KNOB TUNING5323632010 KNO43A32588KNOB SLIDE5433632010 LEN6A32586LENS5213632010 ELECTRICAL COMPONENTS CF136A32567FILTER CER 455KHZ143D455B00 CF236A32579FILTER CER143E107MSE CF336A27384FILTER CER 10.7MHZ143107G18A IC133A32532IC TA2111F1102111F00 IC233A32591IC 2073D1102073D00 JK141A27389JACK HEADPHONE145H005000 SW39A32594SWITCH14923D7VG3 T161A32592TRANSFORMER ITF12711327A0 VR42A32593RESISTOR VAR VOLUME1461N20X14 MISCELLANEOUS LAB4A30845LABEL, POPPOPRP1610 USEUCRP1610USE & CARE GUIDEUCRP1610B 1 - 3 ? ? ? ? ? ? ? ?