《Bang-Olufsen-Beocenter-2-Service-Manual-6 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bang-Olufsen-Beocenter-2-Service-Manual-6 电路图 维修手册.pdf(10页珍藏版)》请在收音机爱好者资料库上搜索。
1、Available parts 4.4 Bottom 9020 3320157 Cover f/CD 9021 2938375 Rubber bushing 9022 3947022 Tape f/bottom 9023 3169013 Cover f/socket 9024 3170067 Thermal conductive rubber 9025 2622011 Thermal conductive rubber 9026 3114031 Bottom incl. pos. nos. 9022, 9024, 9025, 9028 9027 3103013 Aluminium foot 9
2、028 3103000 Rubber foot, small 9029 3103001 Rubber foot, large W11 6200036 Cable w/holder, right W12 6200028 Cable w/holder, left PCB2 8000098 Top Interface PCB77 8000164 DVD Main Board Assy PCB95 8420004 DVD Traverse Mechanism incl. pos. nos. 9020, 9021 x 4 pcs. Survey of screws 1 2011048 Screw 2.5
3、 x 8mm 2 2019033 Screw 2.5 x 6mm 9 2042000 Screw 4 x 3.5mm RadioFans.CN 收音机爱 好者资料库 4.5 Available parts Socket unit 9040 9041 9042 9043 9044 9045 9046 9047 P14 P12 86 6 60 1 50 10 10 10 11 11 11 11 11 11 11 11 11 11 11 12 12 10 10 12 12 Incl. pos. no. 9043 RadioFans.CN 收音机爱 好者资料库 Available parts 4.6
4、Socket unit 9040 3114045 Top f/socket unit 9041 8052029 Socket chassis (PCB1, PCB6, PCB50) 9042 3114048 Bottom incl. pos. nos. 9043 9043 3170342 Insulation piece 9044 3950000 Cover f/sockets 9045 6100245 Mains cable, EU 6100328 Mains cable, GB 6100306 Mains cable, US 6100247 Mains cable, JPN 6100248
5、 Mains cable, AUS 6100386 Mains cable, KOR 9046 3165041 Cover f/bottom 9047 3031047 Wall bracket P12 6270864 FM plug w/cable P14 6277717 AM plug w/cable PCB6 8000138 Microprocessor H8 8344323 SW 8343712 EEPROM PCB60 8000099 SMPS PCB86 8000115 Tuner - EU 8000116 Tuner - JPN Survey of screws 10 205201
6、1 Screw 3 x 10mm 11 2015183 Screw 3.5 x 8mm 12 2930021 Screw 3 x 8mm RadioFans.CN 收音机爱 好者资料库 4.7 Available parts Packing BeoCenter 2 3396212 Set of foam 3917224 Foam foil 3392793 Outer carton Socket unit 3396217 Set of foam 3917224 Foam foil 3392795 Outer carton Wire bundles See wiring diagram page
7、3.2. The part no. is printed on the diagram above the wire bundle, as shown. Connection cables W14 6270086 Connection cable, 1.8m - EU 6270087 Connection cable, 3m - EU 6270088 Connection cable, 5m - EU 6270089 Connection cable, 10m - EU 6270090 Connection cable, 1.8m - US 6270091 Connection cable,
8、3m - US 6270092 Connection cable, 5m - US 6270093 Connection cable, 10m - US Parts not shown 3375021 Product cover 3395090 Back-up suitcase 3629000 Screwdriver TX6 3629002 Screwdriver TX8 3375055 Flash kit ServiceTool 3658949 ServiceTool CD-ROM 3375397 Cable kit for ServiceTool, complete Cable kit c
9、onsists of: 6270857 Main cable 6270852 Cable D-SUB-Jack 6277439 Wire, 3 pole 8008922 Minijack f/STB-Controller Available documentation 3538001 Service Center repair guide English, German, French, Italian, Spanish, Danish, Nederlands, Japaneese Guides for BeoCenter 2 and Socket Unit, please see Retai
10、l Ordering System Accessories 8720063 FM dipol antenna 8720047 AM loop antenna Available parts 4.8 Floor stand 2170 9501 9502 9503 9504 2 2 2 2 3 3 3 3 1 1 1 1 1 1 Incl. pos. no. 2 9501 3459446 Top plate 9502 2950033 Tube 9503 3459002 Cover 9504 2752023 Bottom incl pos. no. 2 1 3390667 Bag w/3 x 2 s
11、crews, 2 x hexagon spanners, 6 x spikes pos. no. 3 2 3103392 Foot 3 3103390 Spike 3396234 Foam - order 2 pcs. 3392824 Outer carton 3504728 Guide 4.9 Available parts Stand/Wall bracket 2171 9510 9511 9512 9513 9514 9515 Incl. pos. no. 5 5 5 5 6 4 4 9510 3459448 Top plate 9511 3034400 Cable holder 951
12、2 2950034 Tube 9513 3459447 Cover 9514 2752029 Bottom incl. pos. no. 5 9515 3459449 Wall plate 4 3390626 Bag w/2 x screws, 2 x hexagon spanners 5 3103358 Foot 6 2058016 Screw 6 x 100mm 3396235 Foam - order 2 pcs. 3392825 Outer carton 3504729 Guide Service tips Doing fault searching and measurements,
13、 there is some special features you should be aware of. 1. In order to power up, the Master Unit and Socket Unit needs to be connected thru the interface cable, do to the main SMPS is placed in the Socket Unit, along with the RGB Video processor and microprocessor. 2. Right before signals from the M
14、aster Unit and Socket Unit goes into the interface cable, they are converted into current signals. If you need to measure the signals going in and out the interface cable, you need to measure before or after the converters. 3. All SMPSs in the Master Unit is synchronized along with the SMPSs in the
15、Socket Unit. But the main SMPS in the Socket Unit is only synchronized, along with the rest, when the BeoCenter 2 is receiving AM signal in RADIO mode. If the synchronizing isnt working, it can create a lot of noise in the AM reception. 4. The DVD/CD are not able to start up when the keyboards are o
16、pen or dismantled, doing to exposure of the laser pickup. A little magnet should be used to activate the hall sensor. Disconnect the BeoCenter 2 from the mains, place the magnet and then connect the BeoCenter 2 to the mains again. After start up, the magnet can be removed, and the hall sensor will s
17、till detect the keyboards as closed, which give full functionality with the keyboards open/detached, until load is pressed. See page : 6.17 5. If measurements need to be done on the outlet plugs on the Socket Panel, remember to use the GND in the same plug you are about to measure in. The GND level
18、can vary from plug to plug. 6. All data communication to the DVD interface is done with signal levels on 3.3 volts, if this level vary, it can cause data failure. 7. The VFD display has an auto contrast function, if this fail, the light in the display can vary from very bright to almost black. 8. Th
19、e interface cable between the Master Unit and the Socket Unit is very sensitive to sharp bends or any other large mechanical influence. Damage can result in poor sound/picture quality or fault in the data communication between the Master Unit and Socket Unit. 9. If one of the two IR-modules fails, t
20、he IR sensitivity will be reduced. 10.All analogue audio processing is done in the analogue Audio engine (module 50). The digital SPDIF signal is not going through any processing, beside it is DC levelled on module 01. Service tips, English 5.1 Service Menu There are two ways to enter the service me
21、nu, either by the keyboard or the BEO4 remote. Keyboard : With the BC2 turned on, press “list” then press n and within 3 sec. Press 0 0 GO BEO4 remote : With the BC2 turned on, press “menu” then press n and within 3 sec. Press 0 0 GO Note you have entered the service menu, and have the following opt
22、ions : . Service Menu 1 SW Versions 2 Error List 3 Product ID 4 Service Counters 5 Default Settings 6 Keyboard Test 7 Loader Lock 8 DVD Service Select wanted menu using general menu navigation rules. 1. SW Versions .SW Versions 1 AP 0.90a 2 OS 12.00a 3 IOP 22.00a 4 Tuner 1.10a 5 Master Unit 0.81a 2.
23、 Error List Select from the list NVMEM errors or VMEM errors .Error List 1 NVMEM 2 VMEM The NVMEM and the VMEM menu has the same layout, each menu will display the last 15 errors. 1 is NVMEM (non volatile memory) and 2 is VMEM (volatile memory). The errors in NVMEM are stored permanently, and can be
24、 used if BC2 has been disconnected from mains after an error has occurred. The VMEM only stores errors that have occurred after BC2 has been connected to the mains. 5.2 Service menu, English .NVMEM 1 4F 00000002 10/11/02 2 08 16000000 9/11/02 3 4F 00000002 8/11/02 4 08 16000000 7/11/02 5 4F 00000002
25、 7/11/02 6 08 16000000 6/11/02 7 4F 00000002 5/11/02 8 08 16000000 5/11/02 9 4F 00000002 4/11/02 10 . . -/-/- 11 . . -/-/- 12 . . -/-/- 13 . . -/-/- 14 . . -/-/- 15 . . -/-/- Complete Error Line 1 4F 00000002 10/11/02-09:35:21 Date and time parameter will scroll according to general rules for the er
26、ror, the cursor points to. By pressing n a more detailed view of the corresponding error is shown, .4F 00000002 Date 10/11/02-09:35:21 WATCHDOG RESET Pressing l returns to Error List The Error Layout 1 4F 00000002 10/11/02 09:35:21 Err_no, error_code, error_parm, Date, Time 1-15 dec 0-FF 0-FFFFFFFF
27、dd/mm/yy hh:mm:ss 2digit dec 2digit HEX code 8digit HEX code error_parm are divided into 4 sections digit 1 and 2 XX- error_type digit 3 and 4 -XX- error_param1 digit 5 and 6 -XX- error_param2 digit 7 and 8 -XX error_param3 EP1 = error_parm1 EP2 = error_parm2 EP3 = error_parm3 Error_codes are writte
28、n in bold and error_type in underline Service menu, English 5.3 The Error LIST Is a list of all the possible errors in BC2, its divided into, error_code with the sub parameter error_type, error_type which has 3 sub parameter error_param1, error_ param2 and error_param3. When ever a error that can be
29、 related to HW, SW or MEK, the cause is described, sometimes there can be more than one cause for the corresponding error, all the possible causes are the listed with the most likely listed first. Error_ code Error _type Error_parm 1-3DescriptionCause (check/replace) 00NO APOS ERRORNo error 08APOS I
30、OP ERRORuP H8 Module 10ILLEGAL TIMER IDSW bug, check for AP SW update 11TIMER NOT FREESW bug, check for AP SW update 15ILLEGAL DATE VALUESW bug, check for AP SW update 16ILLEGAL TIME VALUESW bug, check for AP SW update 17ILLEGAL TIMER PARAMETERSSW bug, check for AP SW update 20ILLEGAL SIMPLE MESSAGE
31、 IDSW bug, check for AP SW update 22OUT OF MESSAGE BUFFERSSW bug, check for AP SW update 25ILLEGAL REPOSITORY TYPESW bug, check for AP SW update 26OUT OF REPOSITORIESSW bug, check for AP SW update 27REPOSITORY VIRTUAL LIMIT REACHEDSW bug, check for AP SW update 28NULL POINTER DELETESW bug, check for
32、 AP SW update 29ILLEGAL REPOSITORY ADDRSW bug, check for AP SW update 2AREPOSITORY IS ALLREADY FREESW bug, check for AP SW update 40NON ISR FUNC CALLED FROM ISRSW bug, check for AP SW update 41PHYSICAL STACK LIMIT REACHEDSW bug, check for AP SW update 42STACK VIRTUAL LIMIT REACHEDSW bug, check for A
33、P SW update 43OUT OF IAS OBJETSSW bug, check for AP SW update 44IAS SIGNAL LOSTSW bug, check for AP SW update 45OVERFLOW IN IAS FIFOSW bug, check for AP SW update 47LSL QUEUE NOT ATTACHEDSW bug, check for AP SW update 48SCAN QUEUE NOT ATTACHEDSW bug, check for AP SW update 4AUART 0 QUEUE OT ATTACHED
34、SW bug, check for AP SW update 4BTIIC QUEUE NOT ATTACHEDSW bug, check for AP SW update 4CRIIC QUEUE NOT ATTACHEDSW bug, check for AP SW update 4DOUT OF POWER DOWN CALLBACK OBJSW bug, check for AP SW update 4EPOWER DOWN ENTERED WITH TIMER RUNNINGSW bug, check for AP SW update 4FWATCHDOG RESETCheck fo
35、r others errors in NVMEM 80BAS ERROR 00NO BAS ERRORNo error 01IIC BUS ERRAlways IO_ERROR not in BC2 02Eeprm addrEE WR ERRAlways IO_ERROR not in BC2 03Eeprm addrEE RD ERRAlways IO_ERROR not in BC2 04Eeprm addrEE RD FF ERRAlways IO_ERROR not in BC2 0BEeprm addrEEPROM WRITE OVERFLOWAlways IO_ERROR not
36、in BC2 0CEeprm addrEEPROM CONTROL INIT FAILAlways IO_ERROR not in BC2 0DEeprm addrEEPROM CONTROL CALLOC FAILAlways IO_ERROR not in BC2 A0IO ERROR 00NO APOS IO ERROR 01IIC1 2 ERROR EP 1= 00NO IIC1 2 ERRORUse EP2 EP 1 = 01IIC1 2 ACKNOWLEDGE MISSINGUse EP2 EP 1 = 02IIC1 2 ARBITRATION LOSTUse EP2 EP 1 = 03IIC1 2 BUS BUSYUse EP2 EP 1 = 04IIC1 2 TIMEOUTUse EP2 EP 1 = 05IIC1 2 SLAVE TRANS BUF DIFFUse EP2 EP 1 = 06IIC1 2 SLAVE NOT ADRESSEDUse EP2 EP 1 = 07IIC1 2 SLAVE TRANS BUF ERRUse EP2 5.4 Service menu, English