1、 2008 Bogen Communic ations, Inc . All rights reserved. Spec if ic ations subj ec t to c hange without notic e. 54-2171-01D 1206 CSUB Cei li ng Subwoofer Installation and Use Manual 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 1 RadioFans.CN 收音机爱 好者资料库 2 P r oduct De s cr ip tion Thank you for c
2、hoos ing Boge ns CS UB Ce iling S ubwoofe r . P le as e familiar ize your s e lf with the p r oduct by r e ading and r e vie wing the de s cr ip tions and diagr ams in this manual. Boge ns CS UB de live r s uns ur p as s e d p e r for mance and value . This s ubwoofe r can be ins talle d e ithe r in
3、 s us p e nde d ce iling s tr uctur e s or har d s ur face s (s uch as dr ywall). It is r e ady to ins tall with s winging ar m clamp s that take the p lace of a tile br idge for ins talla- tion in s us p e nde d ce ilings . A var ie ty of s p e ake r p owe r le ve ls ar e e as ily s e le cte d via
4、a fr ont p ane l r otar y s witch. S e ttings for both 70V and 8-ohm s ys te ms ar e p r ovide d. The CS UB fe atur e s a r e movable s nap -lock inp ut conne ctor , p r oviding e as y wir e con- ne ction for inp ut as we ll as loop -thr ough to the ne xt s p e ake r . NOTE The CS UB is not an outdo
5、or s p e ake r . Do not e xp os e the CS UB to r ain or mois tur e . The CS UB s hould only be ins talle d by q ualifie d p e r s onne l. Re comme nde d amp lifie r for 64W 70V us e s hould be 65W 70V. Highe r - p owe r amp lifie r s s hould be us e d with additional cur r e nt limiting, s uch as a
6、fus e . To p r e ve nt injur y, this ap p ar atus mus t be s e cur e ly attache d to the ce iling or wall in accor dance with the ins tallation ins tr uctions . Al ways f ol l ow th e s e bas ic s af e ty pre c autions wh e n ins tal l ing and us ing th e unit: IMPORTANT SAFETY INSTRUCTIONS 1. Re ad
7、 th e s e ins truc tions . 2. Ke e p th e s e ins truc tions . 3. He e d al l warning s . 4. Fol l ow al l ins truc tions . 5. Do not us e th is apparatus ne ar wate r. 6. Cle an unit with d ry c loth . 7. Do not bl oc k any ve ntil ation ope ning s . Ins tal l in ac c ord anc e with th e m anuf ac
8、ture rs ins truc tions . 8. Do not ins tal l ne ar any h e at s ourc e s s uc h as rad iators , h e at re g is te rs , s tove s , or oth e r apparatus (inc l ud ing am pl if ie rs ) th at prod uc e h e at. 9. Do not d e f e at th e s af e ty purpos e of th e pol arize d or g round ing -type pl ug .
9、A pol arize d pl ug h as two bl ad e s with one wid e r th an th e oth e r. A g round ing -type pl ug h as two bl ad e s and a th ird g round ing prong . Th e wid e bl ad e , or th e th ird prong , are provid e d f or your s af e ty. If th e provid e d pl ug d oe s not f it into your outl e t, c ons
10、 ul t an e l e c tric ian f or re pl ac e m e nt of th e obs ol e te outl e t. 10. Prote c t th e powe r c ord f rom be ing wal ke d on or pinc h e d partic ul arly at pl ug s , c onve nie nc e re c e ptac l e s , and th e point wh e re th e y e xit f rom th e apparatus . 11. Only us e attac h m e n
11、ts /ac c e s s orie s s pe c if ie d by th e m anuf ac ture r. An ope ration m anual is provid e d with th e prod uc t. 12. Unpl ug th is apparatus d uring l ig h tning s torm s or wh e n not us e d f or l ong pe riod s of tim e . 13. Re f e r al l s e rvic ing to qual if ie d s e rvic e pe rs onne
12、l . Se rvic ing is re quire d wh e n th e apparatus h as be e n d am ag e d in any way, s uc h as powe r-s upply c ord or pl ug is d am ag e d , l iquid h as be e n s pil l e d or obje c ts h ave f al l e n into th e apparatus , th e apparatus h as be e n e xpos e d to rain or m ois ture , d oe s no
13、t ope rate norm al ly, or h as be e n d roppe d . 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 2 RadioFans.CN 收音机爱 好者资料库 P r oduct Diagr ams Fr o n t Dr awin g (gr ille r em o ved) 1. Dr ive r As s e mbly (in t er n al) 2. Bas s Tuning Ve nt 3. Gr ille Re te ntion Gr oove 4. 24Ce iling Tile Guid
14、e Ar r ows (2) 5. P owe r Tap S e le ction S witch 6. 14-1/2Jois t S p ace Guide Ar r ows (2) 7. Mounting Clamp S cr e ws (4) Side Dr awin g 8. Me tal Back Can 9. S nap -L ock Inp ut Conne ctor 10. Te r minal Cove r (s ide vie w) 11. Mounting Clamp s (4) Rear Dr awin g 12. S afe ty Te the r P oint 1
15、3. S nap -L ock Inp ut Conne ctor 14. Te r minal Cove r (top -down vie w) 15. Wir e Exit S lot 16. Te r minal Cove r Anchor S cr e w (2; one on back, one be low conne ctor ) Fr o n t Dr awin g (gr ille r em o ved) Side Dr awin g 1 Rear Dr awin g 2 3 5 7 8 9 13 14 15 3 12 16 6 4 10 11 54-2171-01D_54-
16、2091-01B.qxd 6/21/12 3:20 PM Page 3 RadioFans.CN 收音机爱 好者资料库 4 S p e ake r P lace me nt The low fr e q ue ncy cap ability of the CS UB allows gr e at fle xibility in its p lace me nt. While full-r ange s p e ake r s will typ ically be ins talle d thr oughout the ce iling in an e ve nly s p r e ad p a
17、tte r n, the CS UB can be p lace d whe r e ve r it is mos t conve nie nt. This us ually me ans whe r e the s ubwoofe r s be s t me e t the ne e ds of the ove r all s ound s ys te m, or may s ome - time s me an whe r e the y be s t fit into the ce iling. This fle xibility is us e ful in ir r e gular
18、ly- s hap e d r ooms or whe n the de p th of the ar e a be hind the ce iling s ur face var ie s . An imp or tant p e r for mance p ar ame te r to ke e p in mind is that the location of the s ub- woofe r will affe ct its outp ut s ound p r e s s ur e le ve l (S P L) within a r oom. Locating the CS UB
19、 clos e to a wall will incr e as e its outp ut by ap p r oximate ly 3 dB r athe r than locating it towar d the ce nte r of the ce iling ar e a. The 3 dB incr e as e will e ffe ctive ly double the amount of outp ut p owe r coming fr om the s ubwoofe r . Locating the CS UB in the cor ne r of a r oom,
20、adjace nt to 2 p e r p e ndicular wall s ur face s , will incr e as e its outp ut by 6 dB. This 6 dB incr e as e e ffe ctive ly q uadr up le s the outp ut of the s ubwoofe r comp ar e d to locating it clos e r towar d the ce nte r of the r oom. The tr ade off for this e xtr a outp ut is a le s s uni
21、for m ove r - all s ound le ve l, e s p e cially in lar ge r ooms . CSUB CSUBCSUB Near Wall: + 3 dB OutputNear Corner: + 6 dB Output Center of Ceiling: Optimum Bass Distribution Most Uniform Sound Level Thr e e p os s ible locations for a CS UB S ubwoofe r within a lar ge r s ound s ys te m: 1 23 No
22、te :The CS UB may be p lace d as clos e as 5 fr om a wall, p r ovide d car e is take n to e ns ur e that mounting clamp s ar e p r op e r ly e xte nde d (s e e In st allat io n s e ction). If mount- ing clamp s cannot be p r op e r ly e xte nde d, anothe r location mus t be found. 54-2171-01D_54-209
23、1-01B.qxd 6/21/12 3:20 PM Page 4 5 IMP ORTANT The r e mus t be a minimum of 11 of ve r tical cle ar ance (12-1/4 if us ing the CK10 S afe ty Cable Kit) be twe e n the fr ont of the mounting s ur face and any othe r s tr uctur e in the ce iling for the s p e ake r to fit. Be for e cutting the full ho
24、le , inve s - tigate for de p th and cle ar ance by cutting a s mall hole , or r e moving the ce iling tile , whiche ve r is ap p licable . S US P ENDED CEILINGS : The clamp s mus t be able to s p an the full 24 (ap p r ox.) be twe e n the ce iling r ails to p r ovide the p r op e r s up p or t for
25、the CS UB. If the r e is inte r fe r e nce with any obje cts in the ce iling to p r e ve nt this , the n anothe r ce il- ing tile location s hould be chos e n. DR YWALL or O THER Har d Ce iling S ur face s : The e dge of the hole mus t have cle ar - ance of at le as t 5 on op p os ite e dge s of the
26、 hole to e ns ur e that the clamp s will be able to s up p or t the CS UB. Ins tallation The uniq ue clamp -mounting s ys te m of the Boge n CS UB not only allows mounting in mos t typ e s of ce iling s ur face thickne s s e s , it take s the e as e of ins tallation two s ignificant s te p s fur the
27、 r : 1. NO TILE BR IDGE IS R EQUIR ED. Be caus e the mounting clamp s ar e e xtr a-long and ve r y dur able , the y can s us p e nd and s up p or t the CS UB acr os s the 24 s p an of a s us p e nde d ce iling. This e liminate s the ne e d for the s e p ar ate tile br idge r e q uir e d for ne ar ly
28、 all ce iling s p e ake r s . 2. A uniq ue ly de s igne d clamp s cr e w as s e mbly can be tighte ne d fr om e ithe r the fr ont or r e ar , allowing the CS UB to be mounte d e ithe r by dr op p ing the ce iling tile onto the r e ar of the CS UB or by dr op p ing the CS UB into the fr ont of the ce
29、 iling tile . This de s ign can s ignificantly acce le r ate the ins tallation p r oce s s . 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 5 6 Ins tallation (cont.) S US P ENDED CEIL INGS : 1.R e move the ce iling tile fr om the ce iling gr id. Cut a 14-1/4 cir cular hole in the ce il- ing tile .
30、 Us e the include d te mp late as a guide . 2.P ut the CS UB face down on a wor kbe nch or on the floor without gr ille ins talle d. 3.P lace the ce iling tile ove r the CS UB, making s ur e the ce iling tile is facing out. It is imp or tant to note the dir e ction of the clamp s : the y mus t be in
31、s talle d s o that the y s p an the dis tance fr om one s ide of the ce iling tile to the othe r (ap p r ox. 24, s e e illus tr ation at r ight). The fr ont of the CS UB is e ngr ave d with guide ar r ows for “24-Inch Ce iling Tile ” (s e e Pr o du ct Diagr ams s e ction). Us e the s e guide s for t
32、his ins tallation. 4.Us ing an e le ctr ic p owe r e d s cr e wdr ive r with the clutch at a low s e tting, tighte n e ach s cr e w until the clamp s ar e jus t s nug agains t the tile s ur face . The CS UBs clamp s can be tighte ne d fr om e ithe r the fr ont or r e ar of the s p e ake r . Us e a N
33、o. 3 P hillip s s cr e wdr ive r whe n wor king fr om the fr ont. Us e a 1/4 flat-blade s cr e wdr ive r whe n wor king fr om the r e ar . If wor king fr om the r e ar of the s p e ake r , the s cr e ws tighte n COUNTERCL OCKWIS E. Do not ove r -tighte n clamp s . Once all four clamp s ar e p r op e
34、 r ly p os itione d and s nug on the ce iling tile , the as s e mbly (CS UB and ce iling tile ) is r e ady to be mounte d in the ce iling gr id. 5.Be for e ins talling the gr ille , make s ur e you have s e le cte d the p r op e r p owe r s e tting on the fr ont p ane l r otar y s witch. R e fe r to
35、 the Select in g Po w er Levels s e ction for ins tr uctions on s e le cting the p owe r le ve l. Ins tall the gr ille as indicate d in the Sp eaker Gr ille In st allat io n 64W 70V P owe r S e ttings (in watts ) 70V : 64, 32, 16, 8, 4, 2 Baffle Mate r ial Fir e -r ate d (94V 0) ABS Back Can Mate r
36、ial He avy-gauge S te e l Te r minations4-Te r minal S nap -Lock Inp ut Conne ctor Include d Acce s s or ie s (1) S nap -Lock Inp ut Conne ctor , (1) S te e l Te r minal Cove r with (2) mounting s cr e ws , and (1) P ackage , Butyl Tap e Op tional Acce s s or ie s10-Ft. S afe ty Cable Kit (CK10) Min
37、imum Ve r tical Cle ar ance (Fr om fr ont of mounting s ur face ) 11 Without S afe ty Cable Attachme nt P oint 12-1/4 With S afe ty Cable Attachme nt P oint Ce iling Cutout14-1/4 dia. S p e ake r We ight20 lb. S p e ake r Dime ns ions15-1/2 dia. x 12-1/2- D L is tingsLis te d to UL S tandar d 60065
38、for US and Canada 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 10 11 The Bogen CSUB Ceiling Subwoofer is warranted to be f ree f rom def ec ts in material and work man- ship f or three (3) years f rom the date of sale to the original purc haser. Any part of the produc t c overed by this warranty
39、 that, with normal installation and use, bec omes def ec tive (as c onf irmed by Bogen upon inspec tion) during the applic able warranty period, will be repaired or replac ed by Bogen, at Bogen s option, provided the produc t is shipped insured and prepaid to: Bogen Fac tory Servic e Department, 50
40、Spring Street, Ramsey, NJ 07446, USA. Repaired or replac ement produc t will be returned to you f reight prepaid. This warranty does not extend to any of our produc ts that have been subj ec ted to abuse, misuse, improper storage, neglec t, ac c ident, improper installation or have been modif ied or
41、 repaired or altered in any manner whatsoever, or where the serial number or date c ode has been removed or def ac ed. THE FOREGOING LIMITED WARRANTY IS BOGENS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERS SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMP
42、LIED, AND ALL IMPLIED WAR- RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HERE- BY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogens liability arising out of the manuf ac ture, sale or supplying of produc ts or their use or dispo- sition, whether based upon w
43、arranty, c ontrac t, tort or otherwise, shall be limited to the pric e of the produc t. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSE- QUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR S
44、UP- PLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exc lusion or limitation of inc idental or c onsequential damages, so the above limitation or exc lusion may not apply to you. This warran- ty gives you spec if ic legal
45、rights, and you may also have other rights whic h vary f rom State to State. Prod uc ts tha t a re out of wa rra nty will a lso b e re pa ire d b y the Boge n Fa c tory Se rvic e De pa rtme nt sa me a d d re ss a s a b ove or c a ll 201-934-8500. The pa rts a nd la b or involve d in the se re pa irs
46、 a re wa r- ra nte d f or 90 d a ys whe n re pa ire d b y the Boge n Fa c tory Se rvic e De pa rtme nt. All shipping c harges in addition to parts and labor c harges will be at the owners expense. All returns require a Return Authorization number. For most ef f ic ient warranty or repair servic e, please inc lude a desc ription of the f ailure. 12/2008 L imite d War r anty; Exclus ion of Ce r tain Damage s 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 11 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500 Fax: 201-934-9832 54-2171-01D_54-2091-01B.qxd 6/21/12 3:20 PM Page 12