1、Specifications subject to change without notice. 2009 Bogen Communications, Inc. All rights reserved. 54-5810-05C 1206 BPA60 Power Ampl ifier I nstal l ation l ow- impedance bal anced ( with optional transformer) , 75mV Hum and Noise:85 dB bel ow rated output Out put Loads:8- ohm/ 25V, 16- ohm, 25V

2、CT, 70V Out put Regul at ion:Better than 2 dB from no l oad to ful l l oad I nput I mpedances:High- impedance, 50k ohms unbal anced; l ow- impedance, 600 ohms, bal anced ( with optional transformer) Lo- cut Fil t er:- 10 dB at 100 Hz ( switch- sel ectabl e) Cont rol s and I ndicat ors:Fr ont Panel I

3、 l l uminated on/ off power switch Rear Panel I nput l evel control , circuit breaker reset, l o- cut fil ter switch Power Consumpt ion:120V AC, 60 Hz, 180W at ful l rated output Thermal Emissions (ful l power):204. 9 BTU/ hr. Overl oad Prot ect ion:Transient protection diodes, el ectrical circuit b

4、reaker, thermostat Operat ing Temperat ure Range:- 4 F to 131 F ( - 20 to +55 C) at rated output Auxil iary Recept acl e (not swit ched): Three- wire grounded* , 300W maximum, 2. 5A ( internal l y fused) Dimensions:15- 1/ 4W x 3- 1/ 2H x 8- 1/ 4D Finish:Bl ack Product Weight :17 l bs. Approval s:Lis

5、ted to UL Standard 60065 for US and Canada Accessories:Model TL600, 600- ohm l ine- matching transformer; Model TL100, 1: 1 ratio transformer; Model RPK53 rack panel brackets *This r eceptacle will be gr ounded only if the power amplifier has been gr ounded pr oper ly. Technical Specificat ions Radi

6、oFans.CN 收音机爱 好者资料库 NOTI CE:Every effort was made to ensure that the information in this guide was compl ete and accurate at the time of printing. However, information is subject to change. WARNI NG: To reduce the risk of Fire or El ectric Shock, Do Not Expose this apparatus to rain or moisture. App

7、aratus shal l not be exposed to dripping or spl ashing and no objects fil l ed with l iquids, such as vases shal l be pl aced on the apparatus. WARNI NG: Onl y connect unit to AC mains outl et providing protective earthing connection. NOTE:Mains pl ug is used as disconnect device from the mains and

8、shal l remain readil y accessibl e and operabl e. CAUTI ON: These servicing instructions are for use by qual ified service per- sonnel onl y. To reduce the risk of el ectric shock, do not perform any servicing other than that contained in the operating instructions unl ess you are qual ified to do s

9、o. CAUTI ON: DO NOT I NSTALL OR PLACE THI S UNI T I N A BOOKCASE, BUI LT- I N CABI NET , OR I N ANOTHER CONFI NED SPACE. ENSURE THE UNI T I S WELL VENTI LATED. TO PREVENT THE RI SK OF SHOCK OR FI RE HAZARD DUE TO OVER- HEATI NG, ENSURE THAT CURTAI NS AND ANY OTHER MATERI ALS DO NOT OBSTRUCT THE VENT

10、I LATI ON VENTS. Al ways fol l ow t hese basic safet y precaut ions when inst al l ing and using t he unit : I MPORTANT SAFETY I NSTRUCTI ONS 1. Read these instructions. 2. Keep these instructions. 3. Heed al l warnings. 4. Fol l ow al l instructions. 5. Do not use this apparatus near water. 6. Cl e

11、an unit with dry cl oth. 7. Do not bl ock any ventil ation openings. I nstal l in accordance with the manufacturer s instructions. 8. Do not instal l near any heat sources such as radiators, heat registers, stoves, or other apparatus ( incl uding ampl ifiers) that produce heat. 9. Do not defeat the

12、safety purpose of the pol arized or grounding- type pl ug. A pol arized pl ug has two bl ades with one wider than the other. A grounding- type pl ug has two bl ades and a third grounding prong. The wide bl ade, or the third prong, are provided for your safety. I f the provided pl ug does not fit int

13、o your outl et, consul t an el ectrician for repl acement of the obsol ete outl et. 10. Protect the power cord from being wal ked on or pinched particul arl y at pl ugs, convenience receptacl es, and the point where they exit from the apparatus. 11. Onl y use attachments/ accessories specified by th

14、e manufacturer. 12. Unpl ug this apparatus during l ightning storms or when not used for l ong periods of time. 13. Refer al l servicing to qual ified service personnel . Servicing is required when the apparatus has been damaged in any way, such as power- suppl y cord or pl ug is damaged, l iquid ha

15、s been spil l ed or objects have fal l en into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normal l y, or has been dropped. CAUTI ON RI SK OF ELECTRI C SHOCK DO NOT OPEN CAUTI ON: TO PREVENT THE RI SK OF ELECTRI C SHOCK, DO NOT REMOVE ANY FRONT/ BACK COVERS OR

16、 PANELS. NO USER- SERVI CEABLE PARTS I NSI DE. REFER SERVI CI NG TO QUALI FI ED PERSONNEL. The excl amation point within an equi- l ateral triangl e is intended to al ert the user to the presence of important operating and maintenance ( servicing) instructions. The l ightning fl ash with arrowhead s

17、ym- bol , within an equil ateral triangl e, is in- tended to al ert the user to the presence of uninsul ated dangerous vol tage within the product s encl osure that may be of sufficient magnitude to constitute a risk of el ectric shock to persons. RadioFans.CN 收音机爱 好者资料库 I nst al l at ion Rack Mount

18、 ed I nst al l at ion The ampl ifier may be mounted in a standard 19” equipment rack, by using the Bogen Model RPK53 Rack Panel Kit ( accessory; sol d separatel y) , which incl udes two brackets and the necessary hardware for instal l ation. NOTE: Befor e installing the amplifier in a r ack, install

19、 any accessor y tr ansfor mer s r equir ed. See Input Connections section. Attach one of the RPK53 brackets to each side of the unit and se- cure ( with screws provided) through the hol es on the side panel . Each bracket measures 2”W x 3- 1/ 2”H x 1”D. Vent il at ion The ampl ifier generates heat d

20、uring operation. I t must be prop- erl y ventil ated to prevent excessive temperature rise. I f other heat- producing equipment, or several ampl ifiers have been instal l ed in an encl osed rack or cabinet, you must ensure that there is space above and bel ow the ampl ifier( s) to al l ow for passiv

21、e cool ing. I t is recommended that the ampl ifier be instal l ed on the bottom of a rack or above any equipment that does not produce heat. Power and Grounding The three- wire AC l ine cord has a three- prong pl ug which shoul d be pl ugged into a properl y grounded, three- wire, 120V 60Hz outl et.

22、 I t is important to ground the ampl ifier. Auxil iary Power Recept acl e Caution:The fr ont panel POWER switch does not contr ol the aux- iliar y r eceptacle. The AUX POWER receptacl e on the rear panel is a three- wire grounded outl et that may be used to suppl y power to accessory equipment in th

23、e sound system. Ensure that the accessory equip- ment does not require more than 300 watts. Equipment connected to the auxil iary receptacl e wil l be grounded, provided the ampl ifier l ine cord has been properl y grounded. The outl et is protected by an internal fuse. I nput Connect ions High- I m

24、pedance I nput A high- impedance input is provided by standard RCA jacks (see Fig. 1) . An input signal of 300mV is required for ful l rated output. Low- I mpedance Bal anced I nput Caution: To avoid electr ic shock, be sur e to disconnect AC Power Cor d befor e r emoving the cover of the amplifier

25、unit. Warning: DO NOT per for m any function r equir ing the r emoval of the cover of the amplifier unless you ar e qualified to do so. A bal anced input, provided at the BAL LO- Z terminal strip ( Fig. 1) , requires the instal l ation of a Bogen Model TL600 l ine- matching transformer. Remove the t

26、op cover of the unit and instal l the trans- former in the socket designated XT1 ( see Fig. 2 on back page) on the printed circuit board. I f an unbal anced input is required, connect a jumper from the GND terminal to an adjacent input terminal . Bridging I nput Caution: To avoid electr ic shock, be

27、 sur e to disconnect AC Power Cor d befor e r emoving the cover of the amplifier unit. Warning: DO NOT per for m any function r equir ing the r emoval of the cover of the amplifier unless you ar e qualified to do so. The inputs of two or more ampl ifiers may be paral l el ed by instal l ing accessor

28、y transformer TL100 ( for up to 6 ampl ifiers) in the trans- former socket designated XT1 ( see Fig. 2) on the printed circuit board. Connect the signal source to the BAL LO- Z terminal strip and connect the cabl e shiel d to the GND terminal . For an unbal - anced input, connect a jumper wire from

29、the GND terminal to an adjacent input terminal . I nput from Anot her Ampl ifier The BPA60 may be driven from an ampl ifier that provides a 25V or 70V constant vol tage output. Connect the output of the driver ampl ifier to one of the HI - Z input jacks via a resistor network ( see Fig. 3) . These r

30、esistors are in addition to the normal l oudspeaker l oad impedance on the output of the driver ampl ifier. Out put Connect ions Caution: Follow local electr ical codes when connecting ampli- fier output. Figure 1shows the l ocation and impedance val ues for the output terminal strip. Cl ass 2 wirin

31、g is acceptabl e for output l oads. Speakers The BPA60 features output connectors for 16- ohm,8- ohm/ 25V, 25VCT and 70V speakers. The ampl ifier provides outputs for 25V and 70V speakers. 70- vol t speaker connections are made between the 70V and COM terminal s on the output terminal strip. The COM

32、 and GND terminal s of the output terminal strip are connected using a shorting cl ip. The shorting cl ip enabl es the ampl ifier output to act as an unbal anced output ( one side of the output connected to ground) . I f desired, the output can be made to be a bal anced output with no connection to

33、ground. To bal - ance the output, simpl y remove the shorting cl ip. Al l speaker con- nections remain the same as above. 25V speaker connections are done in the same manner. Hum I f the connections between the signal sources and ampl ifier are in- correct or defective, hum- type interference may oc

34、cur. Check for proper grounding, broken wires or shiel ds, poor connector contacts, etc. Keep input cabl es away from speaker cabl es and speaker cabl es away from AC power l ines. Where auxil iary equipment is used, it may be necessary to connect a separate ground wire from the chassis of such equi

35、pment to a suitabl e earth ground. Fig. 1 - BPA60 Rear Panel Connect ion Diagram RadioFans.CN 收音机爱 好者资料库 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500 Fax: 201-934-9832 The Bogen BPA60 Ampl ifier is warranted to be free from defects in material and workmanship for two ( 2) years from

36、the date of sal e to the original purchaser. Any part of the product covered by this warranty that, with normal instal l ation and use, becomes defective ( as confirmed by Bogen upon inspection) during the appl icabl e warranty period, wil l be repaired or repl aced by Bogen, at Bogens option, provi

37、ded the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. Repaired or repl acement product wil l be returned to you freight prepaid. This warranty does not extend to any of our prod- ucts that have been subjected to abuse, misuse, i

38、mproper storage, negl ect, accident, improper instal l ation or have been modified or repaired or al tered in any manner whatsoever, or where the serial number or date code has been removed or defaced. THE FOREGOI NG LI MI TED WARRANTY I S BOGENS SOLE AND EXCLUSI VE WARRANTY AND THE PURCHASERS SOLE

39、AND EXCLUSI VE REMEDY. BOGEN MAKES NO OTHER WARRANTI ES OF ANY KI ND, EI THER EXPRESS OR I MPLI ED, AND ALL I MPLI ED WARRANTI ES OF MERCHANTABI LI TY OR FI TNESS FOR A PARTI CULAR PURPOSE ARE HEREBY DI SCLAI MED AND EXCLUDED TO THE MAXI MUM EXTENT ALLOWABLE BY LAW. Bogen s l iabil ity arising out o

40、f the manufacture, sal e or sup- pl ying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shal l be l imited to the price of the product. I N NO EVENT SHALL BOGEN BE LI ABLE FOR SPECI AL, I NCI DENTAL OR CONSEQUENTI AL DAMAGES (I NCLUDI NG, BUT NOT L

41、I MI TED TO, LOSS OF PROFI TS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARI SI NG OUT OF THE MANUFACTURE, SALE OR SUPPLYI NG OF PRODUCTS, EVEN I F BOGEN HAS BEEN ADVI SED OF THE POSSI BI LI TY OF SUCH DAMAGES OR LOSSES.Some States do not al l ow the excl usion or l imitation of incidental or consequenti

42、al damages, so the above l imitation or excl usion may not appl y to you. This warranty gives you specific l egal rights, and you may al so have other rights which vary from State to State. Products that are out of warranty wil l al so be repaired by the Bogen Factory Service Department same address

43、 as above or cal l 201- 934- 8500. The parts and l abor invol ved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. Al l shipping charges in addition to parts and l abor charges wil l be at the owner s expense. Al l returns require a Return Authorizati

44、on number. For most efficient warranty or repair service, pl ease incl ude a description of the fail ure. 12/ 2008 Limit ed Warrant y; Excl usion of Cert ain Damages Operat ion Power:The Power Switch appl ies power to the ampl ifier; it does not control any associated equipment which may be connecte

45、d to the auxil iary power receptacl e on the rear panel . The switch l amp wil l il l uminate when power has been appl ied to the unit. Lo- Cut Fil t er Swit ch:The LO- CUT fil ter switch, l ocated on the rear panel , provides 10 dB attenuation at 100 Hz. I nput Level Cont rol :The I nput Level cont

46、rol ( screwdriver- ad- justabl e) , l ocated on the rear panel , is used to adjust the input sig- nal appl ied to the ampl ifier. Turn the control cl ockwise to increase the l evel . Caution: Many loudspeaker s may be damaged if over dr iven. Ther efor e, always begin system setup with the Input Lev

47、el contr ol fully counter clockwise and gr adually incr ease the setting to obtain the desir ed output level. Thermal Cut - Out The ampl ifier is protected by a thermal cut- out which shoul d not trip under normal conditions. I f it trips, check for inadequate ven- til ation of the unit or overl oad

48、ing. The cut- out wil l automatical l y reset after cool ing. Circuit Breaker:I f the AC circuit breaker opens, the power switch l amp wil l go out and the ampl ifier wil l have no output; however, there wil l be power at the AUX POWER receptacl e on the rear panel . Set the POWER switch to OFF and

49、momentaril y depress the red but- ton on the circuit breaker to reset it. Return the POWER switch to ON. I f the circuit breaker trips again, do not attempt to reset it; have the troubl e investigated by a qual ified technician. Fig. 2 - BPA60 Print ed Circuit BoardFig. 3 - I nput From Anot her Ampl ifier TRANSFORMER SOCKET XT1 AT 70V R1 = 10K, 1/ 2W AT 25V R1 = 3. 3K, 1/ 2W 70V R1 R2 100 1/ 2W GND OUTPUT TERMI NAL STRI P OF DRI VER AMPLI FI ER TO HI GH I MPEDANCE I NPUT OF POWER AMPLI FI ER